Diederik W Dippel1, Charles B Majoie2, Yvo B Roos2, Aad van der Lugt2, Robert J van Oostenbrugge2, Wim H van Zwam2, Hester F Lingsma2, Peter J Koudstaal2, Kilian M Treurniet2, Lucie A van den Berg2, Debbie Beumer2, Puck S Fransen2, Olvert A Berkhemer2. 1. From the Departments of Neurology (D.W.D., P.J.K., P.S.F., O.A.B.), Radiology (A.v.d.L.), and Public Health (H.F.L.), Erasmus MC University Medical Center Rotterdam, The Netherlands; Departments of Radiology (C.B.M., K.M.T., P.S.F., O.A.B.) and Neurology (Y.B.R., L.A.v.d.B.), Academic Medical Center, Amsterdam, The Netherlands; and Departments of Neurology (R.J.v.O., D.B.) and Radiology (W.H.v.Z., O.A.B.), Maastricht University Medical Center, The Netherlands. d.dippel@erasmusmc.nl. 2. From the Departments of Neurology (D.W.D., P.J.K., P.S.F., O.A.B.), Radiology (A.v.d.L.), and Public Health (H.F.L.), Erasmus MC University Medical Center Rotterdam, The Netherlands; Departments of Radiology (C.B.M., K.M.T., P.S.F., O.A.B.) and Neurology (Y.B.R., L.A.v.d.B.), Academic Medical Center, Amsterdam, The Netherlands; and Departments of Neurology (R.J.v.O., D.B.) and Radiology (W.H.v.Z., O.A.B.), Maastricht University Medical Center, The Netherlands.
Abstract
BACKGROUND AND PURPOSE:Intra-arterial treatment by means of retrievable stents has been proven safe and effective. In MR CLEAN (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands), the choice of the type of thrombectomy device was left to the discretion of the interventionist. The aim of this study was to explore the differences in functional outcome, neurological recovery, reperfusion, extent of infarction, and adverse events according to stent type and make. METHODS: The primary outcome was functional outcome at 90 days, assessed with the modified Rankin Scale (mRS). Neuroimaging outcomes included occlusion on computed tomographic angiography at 24 hours, infarct volume at 5 to 7 days, and modified thrombolysis in cerebral infarction scores. Safety outcomes included death within 90 days and any symptomatic intracerebral hemorrhage. We analyzed possible interactions between stent type and treatment with multiple regression models. Treatment effects were adjusted for patient age, stroke severity, and collateral score. RESULTS: Of the 500 patients included in the trial, 233 were allocated to intervention. Of these, 124 (53%) were first treated with Trevo (adjusted common odds ratio for shift on the mRS [acOR, 1.98; 95% confidence interval, 1.30-2.92]), 31 (13%) with Solitaire (acOR, 1.90; 95% confidence interval, 0.97-3.73), 40 (17%) with other retrievable stents or mechanical devices (acOR, 0.96; 95% confidence interval, 0.51-3.93], and 38 (16%) could not be treated. There was no interaction between device and treatment effect on functional outcome and all other secondary and safety outcomes. CONCLUSIONS: We found no evidence for a differential effect of thrombectomy for acute ischemic stroke by type of stent. CLINICAL TRIAL REGISTRATION: URL: http://www.isrctn.com. Unique identifier: ISRCTN10888758.
RCT Entities:
BACKGROUND AND PURPOSE: Intra-arterial treatment by means of retrievable stents has been proven safe and effective. In MR CLEAN (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands), the choice of the type of thrombectomy device was left to the discretion of the interventionist. The aim of this study was to explore the differences in functional outcome, neurological recovery, reperfusion, extent of infarction, and adverse events according to stent type and make. METHODS: The primary outcome was functional outcome at 90 days, assessed with the modified Rankin Scale (mRS). Neuroimaging outcomes included occlusion on computed tomographic angiography at 24 hours, infarct volume at 5 to 7 days, and modified thrombolysis in cerebral infarction scores. Safety outcomes included death within 90 days and any symptomatic intracerebral hemorrhage. We analyzed possible interactions between stent type and treatment with multiple regression models. Treatment effects were adjusted for patient age, stroke severity, and collateral score. RESULTS: Of the 500 patients included in the trial, 233 were allocated to intervention. Of these, 124 (53%) were first treated with Trevo (adjusted common odds ratio for shift on the mRS [acOR, 1.98; 95% confidence interval, 1.30-2.92]), 31 (13%) with Solitaire (acOR, 1.90; 95% confidence interval, 0.97-3.73), 40 (17%) with other retrievable stents or mechanical devices (acOR, 0.96; 95% confidence interval, 0.51-3.93], and 38 (16%) could not be treated. There was no interaction between device and treatment effect on functional outcome and all other secondary and safety outcomes. CONCLUSIONS: We found no evidence for a differential effect of thrombectomy for acute ischemic stroke by type of stent. CLINICAL TRIAL REGISTRATION: URL: http://www.isrctn.com. Unique identifier: ISRCTN10888758.
Authors: Volker Maus; Daniel Behme; Christoph Kabbasch; Jan Borggrefe; Ioannis Tsogkas; Omid Nikoubashman; Martin Wiesmann; Michael Knauth; Anastasios Mpotsaris; Marios Nikos Psychogios Journal: Clin Neuroradiol Date: 2017-02-13 Impact factor: 3.649
Authors: Marion Boulanger; Bertrand Lapergue; Francis Turjman; Emmanuel Touzé; René Anxionnat; Serge Bracard; Michel Piotin; Benjamin Gory Journal: Interv Neuroradiol Date: 2019-02-04 Impact factor: 1.610
Authors: Sarah Christina Reitz; Ellen Gerhard; Stella Breuer; Ferdinand Oliver Bohmann; Waltraud Pfeilschifter; Joachim Berkefeld Journal: J Clin Med Date: 2022-05-17 Impact factor: 4.964
Authors: Laura Strada; Jonathan Y Streifler; Bruno Del Sette; Matteo Puntoni; Antonio Castaldi; Daria Bianchini; Massimo Del Sette Journal: Neurol Sci Date: 2017-07-19 Impact factor: 3.307