Literature DB >> 27598320

Single-Incision Mini-Slings: Obturator Complex Pull-Out-Force Measurements.

Florian Lenz1, Sara Doll, Christof Sohn, Kerstin A Brocker.   

Abstract

AIM: To evaluate the different pull-out-force out of the obturator membrane and the obturator internus muscle of 2 mini-sling systems for stress urinary incontinence (SUI) treatment.
MATERIAL AND METHODS: In a prospective study, the pull-out-force measurements were performed on 8 female cadaver pelvises, both on the obturator membrane and internal muscle, using the force measurement device PCE-FM50 (PCE Instruments). Tested were the hooks of 2 on the market available mini-sling kits (MiniArc by American Medical System; Ajust by BARD Inc.). Connected to the force measurement device, the hooks were placed into the obturator membrane and the obturator internus muscle. Mean value and SD were documented.
RESULTS: On the complete obturator complex, Ajust showed a significantly higher pull-out-force (2,561.75 ± 638.8 g) than did the MiniArc (1,780.69 ± 442.3 g), p = 0.025. No significant differences were performed on the obturator membrane.
CONCLUSIONS: The Ajust mini-sling hook is, given the objective results, more stably attached to the obturator complex than the MiniArc. Yet, both systems are sufficiently attachable to the evaluated anatomic structures, fulfilling the needed requirements for their use in the treatment of SUI.
© 2016 S. Karger AG, Basel.

Entities:  

Keywords:  Mini-slings; Obturator complex pull-out-force; Stress urinary incontinence

Mesh:

Year:  2016        PMID: 27598320     DOI: 10.1159/000449156

Source DB:  PubMed          Journal:  Gynecol Obstet Invest        ISSN: 0378-7346            Impact factor:   2.031


  3 in total

1.  Clinical outcomes on tension-releasing suture appendage on single-incision sling devices for postoperative voiding dysfunction involving undue tape tension.

Authors:  Tsia-Shu Lo; Sandy Chua; Ling-Hong Tseng; Cheng-Yu Long; Chuan-Chi Kao; Wu-Chiao Hsieh
Journal:  Int Urogynecol J       Date:  2018-11-28       Impact factor: 2.894

2.  Single-incision midurethral sling shows less pain and similar success rate in a short-term follow-up compared to the transobturator tape method in the treatment of stress urinary incontinence.

Authors:  Ahmet Karakeçi; Taner Cüneyt Eftal; Ahmet Keleş; Ceren Gölbaşı; Rahmi Onur
Journal:  Turk J Urol       Date:  2019-10-25

3.  Adjustable mini-sling compared with conventional mid-urethral slings in women with urinary incontinence: a 3-year follow-up of a randomized controlled trial.

Authors:  Vasileios Alexandridis; Martin Rudnicki; Ulf Jakobsson; Pia Teleman
Journal:  Int Urogynecol J       Date:  2019-06-20       Impact factor: 2.894

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.