| Literature DB >> 27596838 |
Xing-Kang He1,2, Dan Liu3, Lei-Min Sun4,5.
Abstract
BACKGROUND: Gastric intestinal metaplasia (IM) is generally considered as a precancerous condition, a related risk factor for intestinal-type gastric cancer. However, an accurate endoscopic diagnosis of IM is a clinical challenge. Confocal Laser Endomicroscopy (CLE) is a newly technique that can provide real-time magnified images and visualize tissues at cellular or subcellular levels. The aim of this study is to clarify the diagnostic value of CLE in detection of IM in patients at high risk of gastric cancer.Entities:
Keywords: Confocal laser endomicroscopy; Diagnostic performance; Intestinal metaplasia
Mesh:
Year: 2016 PMID: 27596838 PMCID: PMC5011919 DOI: 10.1186/s12876-016-0515-3
Source DB: PubMed Journal: BMC Gastroenterol ISSN: 1471-230X Impact factor: 3.067
Fig. 1Literature search flow diagram
Characteristics of the selected studies
| Study(Year) | Country | Numbers of patients,n | Lesions examined, n | Mean age,year | M/F* | Histological reference standard | Endoscopists Number,n | Type of CLE system |
|---|---|---|---|---|---|---|---|---|
| Guo etal [ | China | 53 | 267 | 51 | 38/15 | IM** | 3 | e-CLE |
| Zhen etal [ | China | 85 | 67 | 55 | 45/40 | IM | 3 | e-CLE |
| Rapat etal[ | Thai land | 60 | 120 | 62.8 | 33/27 | IM | 5 | P-CLE |
| Lim etal [ | Singapore | 20 | 125 | 62.5 | 15/5 | IM | 1 | P-CLE |
IM intestinal metaplasia M/F male to female, CLE Confocal Laser Endomicroscopy, e-CLE endoscope-based, CLE P-CLE probe-based CLE
Quality of articles using the QUADAS tool
| Study | Risk of bias | Applicability Concerns | |||||
|---|---|---|---|---|---|---|---|
| Patient selection | Index test | Reference standard | Flow and timing | Patient selection | Index test | Reference standard | |
| Guo etal [ | L | L | L | L | L | L | L |
| Zhen etal [ | L | L | L | L | L | L | L |
| Rapat etal [ | H | L | L | L | H | L | L |
| Lim etal [ | L | L | L | L | L | L | L |
L low risk; H high risk; U nuclear risk
Fig. 2Forest plot showing pooled sensitivity and specificity for CLE to diagnose IM. a forest plots of the sensitivity; b forest plots of the specificity
Fig. 3Forest plot showing positive LR and negative LR of CLE for IM. a forest plots of the positive LR; b forest plots of the negative LR. LR, likelihood ratio
Fig. 4SROC curve of CLE for IM. SROC, summary receiver operating characteristic, AUC: Area under curve; SE: Standard error
Fig. 5Forest diagnostic odds ratio of CLE for IM
Fig. 6Deeks’ funnel plot to assess publication bias of selected studies