Literature DB >> 27593509

Intense focused ultrasound (IFUS) with a modified parameter on facial tightening: A study on its safety and efficacy.

Dong Hye Suh1, Dae Hong Kim2, Hee Kyung Lim1, Sang Jun Lee1, Kye Yong Song3, Hei Sung Kim2.   

Abstract

BACKGROUND: Intense focused ultrasound (IFUS) is a novel treatment modality for skin laxity. The delivery of thermal energy to the deeper tissue layers effectively tightens the skin but can also cause significant fat atrophy, limiting its use in patients with a lean face.
OBJECTIVES: We sought to evaluate the safety and efficacy of modified IFUS on facial rejuvenation. PATIENTS AND METHODS: This was a retrospective, single-center study of 28 subjects with age-related facial laxity who underwent 3 sessions of IFUS (UltraskinTM, WONTECH Co., Daejeon, Korea) at an interval of four weeks, and then followed up for three months. IFUS was first applied using a 4-MHZ, 4.5-mm transducer followed by a 7-MHZ, 3-mm transducer. Approximately 200-300 treatment lines were applied to the face during each session. Standardized photographs were taken at baseline and follow-ups and were assessed by two independent dermatologists. A questionnaire was used to evaluate patient satisfaction and the incidence of adverse reactions.
RESULTS: Twenty-eight subjects with mild-to-moderate age-related facial laxity were included in the study. The mean age of the subjects was 48 (range 29-74) years. About 32.1% of the subjects showed significant improvement and 57.1% showed improvement of facial laxity in their follow-up photographs. All of them (100%) replied that they were either greatly satisfied or satisfied with the results at three-month follow-up. None of the subjects experienced any serious adverse events including fat atrophy after the procedure.
CONCLUSION: Modified IFUS (three sessions, four weeks apart, 200-300 treatment lines per session) can be safely performed with good clinical results.

Entities:  

Keywords:  Efficacy; modified high-intensity focused ultrasound (HIFU); safety

Mesh:

Year:  2016        PMID: 27593509     DOI: 10.1080/14764172.2016.1225961

Source DB:  PubMed          Journal:  J Cosmet Laser Ther        ISSN: 1476-4172            Impact factor:   2.247


  2 in total

1.  Customized Treatment Using Microfocused Ultrasound with Visualization for Optimized Patient Outcomes: A Review of Skin-tightening Energy Technologies and a Pan-Asian Adaptation of the Expert Panel's Gold Standard Consensus.

Authors:  Je-Young Park; Frank Lin; Atchima Suwanchinda; Rungsima Wanitphakdeedecha; Jonathan Yu; Ting Song Lim; Jeng Feng Chen; Wilson Ho; Joyce Lim; Lanny Juniarty; Yong Seng Kee; Seong Jae Youn; Sabrina Fabi
Journal:  J Clin Aesthet Dermatol       Date:  2021-05-01

2.  Microfocused ultrasound with visualization: Consensus on safety and review of energy-based devices.

Authors:  Tatjana Pavicic; John R Ballard; Tatiana Bykovskaya; Niamh Corduff; Cyro Hirano; Je-Young Park; Alena Saromytskaya; Julia Sevi; Suyan Vasconcelos
Journal:  J Cosmet Dermatol       Date:  2021-12-24       Impact factor: 2.189

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.