Design and characterisation of a real time proton and carbon ion radiography system based on scintillating optical fibres.

D Lo Presti1, D L Bonanno2, F Longhitano2, D G Bongiovanni2, G V Russo3, E Leonora2, N Randazzo2, S Reito2, V Sipala4, G Gallo5.   

Abstract

This paper describes the design and characterization of a charged particle imaging system composed of a position sensitive detector and residual range detector. The position detector consists of two identical overlying and orthogonal planes each of which consists of two layers of pre-aligned and juxtaposed scintillating fibres. The 500μm square section fibres are optically coupled to two Silicon Photomultiplier arrays using a channel reduction system patented by the Istituto Nazionale di Fisica Nucleare. The residual range detector consists of sixty parallel layers of the same fibres used in the position detector each of which is optically coupled to a Silicon Photomultiplier array by wavelength shifting fibres. The sensitive area of the two detectors is 9×9cm(2). Characterising the position sensitive and the residual range detectors to reconstruct the radiography, is fundamental to validating the detectors' designs. The proton radiography of a calibrated target in imaging conditions is presented. The spatial resolution of the position sensitive detector is about 150μm and the range resolution is about 170μm. The performance of the prototypes were tested at CATANA proton therapy facility (Laboratori Nazionali del Sud, INFN, Catania) with energy up to 58MeV and rate of about 10(6) particles per second. The comparison between the simulations and measurements confirms the validity of this system.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Optical detector read-out strategy; Proton imaging; Real-time proton radiography; Scintillating optical fibres

Mesh:

Substances:

Year:  2016        PMID: 27575280     DOI: 10.1016/j.ejmp.2016.08.015

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

1.  PRaVDA: The first solid-state system for proton computed tomography.

Authors:  Michela Esposito; Chris Waltham; Jonathan T Taylor; Sam Manger; Ben Phoenix; Tony Price; Gavin Poludniowski; Stuart Green; Philip M Evans; Philip P Allport; Spyros Manolopulos; Jaime Nieto-Camero; Julyan Symons; Nigel M Allinson
Journal:  Phys Med       Date:  2018-11-09       Impact factor: 2.685

2.  Technical Note: A fast and monolithic prototype clinical proton radiography system optimized for pencil beam scanning.

Authors:  Ethan A DeJongh; Don F DeJongh; Igor Polnyi; Victor Rykalin; Christina Sarosiek; George Coutrakon; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Mark Pankuch; John R Winans; James S Welsh
Journal:  Med Phys       Date:  2021-02-04       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.