Literature DB >> 27573796

Evaluation of Parathyroid Lesions With Point Shear Wave Elastography.

Salih Hattapoğlu1, Cemil Göya2, Cihad Hamidi2, Bekir Taşdemir3, Bircan Alan2, Mehmet Sedat Durmaz4, Memik Teke2, Faysal Ekici2.   

Abstract

OBJECTIVES: The aim of our study was to evaluate the shear wave velocity (SWV) of parathyroid lesions by point shear wave elastography (SWE) and to compare their stiffness with that of thyroid nodules and normal thyroid parenchyma quantitatively.
METHODS: Thirty-six patients considered to have parathyroid disorders by clinical and laboratory tests and scintigraphy were enrolled in the study between January 2012 and February 2015. Conventional sonography, Doppler sonography, and the Virtual Touch tissue quantification (VTQ) method of point SWE (Siemens Medical Solutions, Mountain View, CA) were conducted with a linear transducer (4-9 MHz) while the patients were in the supine position. Then we compared our VTQ measurements with pathologic results.
RESULTS: The 36 patients included 31 female and 5 male patients with a mean age ± SD of 49 ± 15.7 years (range, 15-79 years). The mean SWV of parathyroid hyperplasia lesions (n = 4) was 1.46 ± 0.23 m/s, whereas the mean SWV of parathyroid adenomas (n = 32) was 2.28 ± 0.50 m/s. The mean SWV of normal thyroid parenchyma (n = 36) was 1.62 ± 0.20 m/s, and the mean SWV of benign thyroid nodules (n = 21) was 2.25 ± 0.51 m/s. A significant difference was found between SWV values of normal thyroid parenchyma and parathyroid adenoma (P < .001). A cutoff value of 1.73 m/s for adenomas led to 90.0% sensitivity and 80.6% specificity.
CONCLUSIONS: The VTQ method of point SWE may contribute to the discrimination of parathyroid adenomas from the thyroid gland. However, more comprehensive studies are needed.

Entities:  

Keywords:  Virtual Touch tissue quantification; head and neck ultrasound; parathyroid adenoma; shear wave velocity

Mesh:

Year:  2016        PMID: 27573796     DOI: 10.7863/ultra.15.10074

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  5 in total

1.  2D-Shear Wave Elastography in the Evaluation of Parathyroid Lesions in Patients with Hyperparathyroidism.

Authors:  Ioana Golu; Ioan Sporea; Lavinia Moleriu; Anca Tudor; Marioara Cornianu; Adrian Vlad; Romulus Timar; Melania Balas; Daniela Amzar; Mihaela Vlad
Journal:  Int J Endocrinol       Date:  2017-08-06       Impact factor: 3.257

2.  Shear wave elastography in the diagnostics of parathyroid adenomas-new application of the method.

Authors:  Adam Stangierski; Kosma Wolinski; Marek Ruchala
Journal:  Endocrine       Date:  2018-02-21       Impact factor: 3.633

3.  Shear Wave Elastography versus Strain Elastography in Diagnosing Parathyroid Adenomas.

Authors:  Laura Cotoi; Daniela Amzar; Ioan Sporea; Andreea Borlea; Dan Navolan; Flore Varcus; Dana Stoian
Journal:  Int J Endocrinol       Date:  2020-03-17       Impact factor: 3.257

Review 4.  Preoperative and Intraoperative Methods of Parathyroid Gland Localization and the Diagnosis of Parathyroid Adenomas.

Authors:  Jacek Baj; Robert Sitarz; Marek Łokaj; Alicja Forma; Marcin Czeczelewski; Amr Maani; Gabriella Garruti
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

5.  Ultrasound elastography score and strain index in different parathyroid lesions.

Authors:  Bekir Cakir; F Neslihan Cuhaci Seyrek; Oya Topaloglu; Didem Ozdemir; Ahmet Dirikoc; Cevdet Aydin; Sefika Burcak Polat; Berna Evranos Ogmen; Ali Abbas Tam; Husniye Baser; Aylin Kilic Yazgan; Mehmet Kilic; Afra Alkan; Reyhan Ersoy
Journal:  Endocr Connect       Date:  2019-12       Impact factor: 3.335

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.