Literature DB >> 27573071

Predictive parameters of Legionella pneumophila occurrence in hospital water: HPCs and plumbing system installation age.

Ghader Ghanizadeh1, Ali Mirmohamadlou2, Davoud Esmaeli3.   

Abstract

Occurrence of Legionella pneumophila can be relevant to the installation age and the presence of heterotrophic plate counts (HPCs). This research illustrates L. pneumophila contamination of hospital water in accordance with the installation age and the presence of HPCs. One hundred and fifty samples were collected from hot and cold water systems and cultured on R2A and BCYE agar. L. pneumophila identification was done via specific biochemical tests. HPCs and L. pneumophila were detected in 96 and 37.3 % of the samples, respectively. The mean of HPCs density was 947 ± 998 CFU/ml; therefore, 52 % of the samples had higher densities than 500 CFU/ml. High densities of HPCs (>500 CFU/ml) led to colonization of L. pneumophila (≥1000 CFU/ml), mainly observed in cooling systems, gynecological, sonography, and NICU wards. Chi(2) test demonstrated that higher densities (>500 CFU/ml) of HPCs and L. pneumophila contamination in cold water were more frequent than warm water (OR: 2.3 and 1.49, respectively). Univariate regressions implied a significant difference between HPCs density and installation age in positive and negative tests of L. pneumophila (OR = 1.1, p < 0.001, OR = 1.2, p < 0.001). Mann-Whitney U test implied the significant effects of HPCs and installation age on L. pneumophila occurrences (p < 0.001). Spearman correlation and multivariate linear regression revealed significant differences between L. pneumophila and HPCs densities (r s  = 0.33, p < 0.001 and ß = 0.11, p = 0.02), but nonsignificant difference with installation age (r s  = 0.33, p < 0.001 and ß = 0.0, p = 0.91). The occurrence of L. pneumophila, HPCs, and installation age are relevant; so, plumbing system renovation with appropriate materials and promotion of the effective efforts for hospital's water quality assurance is highly recommended.

Entities:  

Keywords:  Heterotroph bacteria; Hospital water; Legionella; Water contamination

Mesh:

Substances:

Year:  2016        PMID: 27573071     DOI: 10.1007/s10661-016-5554-2

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  21 in total

Review 1.  Assessing risk of health care-acquired Legionnaires' disease from environmental sampling: the limits of using a strict percent positivity approach.

Authors:  Joseph G Allen; Theodore A Myatt; David L Macintosh; Jerry F Ludwig; Taeko Minegishi; James H Stewart; Bryan F Connors; Michael P Grant; John F McCarthy
Journal:  Am J Infect Control       Date:  2012-05-24       Impact factor: 2.918

2.  Water quality parameters associated with prevalence of Legionella in hot spring facility water bodies.

Authors:  Shih-Wei Huang; Bing-Mu Hsu; Shu-Fen Wu; Cheng-Wei Fan; Feng-Cheng Shih; Yung-Chang Lin; Dar-Der Ji
Journal:  Water Res       Date:  2010-08-07       Impact factor: 11.236

Review 3.  Bacteriology of drinking water distribution systems: an integral and multidimensional review.

Authors:  G Liu; J Q J C Verberk; J C Van Dijk
Journal:  Appl Microbiol Biotechnol       Date:  2013-09-26       Impact factor: 4.813

4.  Influence of temperature, chlorine residual and heavy metals on the presence of Legionella pneumophila in hot water distribution systems.

Authors:  Anita Rakić; Jelena Perić; Lucija Foglar
Journal:  Ann Agric Environ Med       Date:  2012       Impact factor: 1.447

5.  Evaluation of the usefulness of a new direct immunofluorescence assay (ScanVIT-Legionella) for monitoring hospital water systems contaminated with Legionella spp.

Authors:  S Ditommaso; M Giacomuzzi; M Gentile; C M Zotti
Journal:  Lett Appl Microbiol       Date:  2010-01-15       Impact factor: 2.858

6.  Antibody detection and cross-reactivity among species and serogroups of Legionella by indirect immunofluorescence test.

Authors:  S Ditommaso; M Giacomuzzi; M Gentile; C M Zotti
Journal:  J Microbiol Methods       Date:  2008-06-11       Impact factor: 2.363

7.  Dual infections with different Legionella strains.

Authors:  G Wewalka; D Schmid; T G Harrison; S A Uldum; C Lück
Journal:  Clin Microbiol Infect       Date:  2013-07-30       Impact factor: 8.067

8.  Detection of Legionella spp. and Legionella pneumophila in water samples of Spain by specific real-time PCR.

Authors:  Cristina Grúas; Silvia Llambi; M Victoria Arruga
Journal:  Arch Microbiol       Date:  2013-11-22       Impact factor: 2.552

9.  An evaluation of microbial and chemical contamination sources related to the deterioration of tap water quality in the household water supply system.

Authors:  Yoonjin Lee
Journal:  Int J Environ Res Public Health       Date:  2013-09-06       Impact factor: 3.390

10.  Legionella infection risk from domestic hot water.

Authors:  Paola Borella; M Teresa Montagna; Vincenzo Romano-Spica; Serena Stampi; Giovanna Stancanelli; Maria Triassi; Rachele Neglia; Isabella Marchesi; Guglielmina Fantuzzi; Daniela Tatò; Christian Napoli; Gianluigi Quaranta; Patrizia Laurenti; Erica Leoni; Giovanna De Luca; Cristina Ossi; Matteo Moro; Gabriella Ribera D'Alcalà
Journal:  Emerg Infect Dis       Date:  2004-03       Impact factor: 6.883

View more
  1 in total

1.  Comparison of two culture methods for the enumeration of Legionella pneumophila from potable water samples.

Authors:  Laura A Boczek; Min Tang; Casey Formal; Darren Lytle; Hodon Ryu
Journal:  J Water Health       Date:  2021-06       Impact factor: 2.264

  1 in total