Literature DB >> 27566616

Clinical and radiologic outcomes of the second-generation Trabecular Metal™ glenoid for total shoulder replacements after 2-6 years follow-up.

Juan Paulo Panti1, Simon Tan2, Warren Kuo2, Sebastian Fung3, Kim Walker4, Jed Duff4.   

Abstract

BACKGROUND: A porous tantalum glenoid component for total shoulder replacements was introduced in 2003 to promote biologic ingrowth. However, reports of component failure prompted design modifications. The purpose of this study is to present the largest series to date, of TSR with the second-generation Trabecular Metal™ glenoid component.
METHOD: A radiologic and clinical evaluation of the second-generation TM glenoid was conducted in consecutive cases of 76 shoulders (66 patients) with a mean follow-up of 43.2 months (range 24-72 months). Pre-operative VAS score, patient self-assessed ASES score, active shoulder range of motion, and radiologic assessment were recorded. Patients were recalled for latest follow-up clinical and radiologic evaluation.
RESULTS: On latest follow-up, the mean VAS scores (pre-op: 6.4-latest: 0.9) and ASES scores (pre-op: 36.9-latest: 88.5) improved. Active range of motion improved in all planes. There was no report of glenoid component migration, loosening, or humeral stem subsidence. The incidence of non-progressive radiolucency in the glenoid was 6.6 % (Franklin 1: 3 cases, Franklin 2: 2 cases). Post-operative complications involved dislocation (n = 2) which were reduced in ED, post-operative stiffness (n = 1), transient axillary nerve neuropraxia (n = 1), and supraspinatus tear which underwent arthroscopic repair at 16 months post-op. There were no revision surgeries for implant loosening nor glenoid component fracture at the peg-base plate junction.
CONCLUSIONS: The modifications established in the second-generation TM glenoid resulted to improve early to mid-term survivorship and clinical outcomes in TSR, with promise of long-term implant stability through bony ingrowth. LEVEL OF EVIDENCE: Level IV, case series, treatment study.

Entities:  

Keywords:  Anteroposterior pegs; Ingrowth; Monoblock metal-backed; Second-generation TM glenoid; Tantalum; Total shoulder replacement

Mesh:

Substances:

Year:  2016        PMID: 27566616     DOI: 10.1007/s00402-016-2562-1

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Radiographic and clinical outcomes of second generation Trabecular Metal™ glenoid components in total shoulder arthroplasty.

Authors:  Raymond E Chen; Alexander M Brown; Alexander S Greenstein; Sandeep Mannava; Ilya Voloshin
Journal:  Shoulder Elbow       Date:  2020-03-24

Review 2.  Do Modern Designs of Metal-Backed Glenoid Components Show Improved Clinical Results in Total Shoulder Arthroplasty? A Systematic Review of the Literature.

Authors:  Dong Min Kim; Fahad Alabdullatif; Mohammed Aldeghaither; Myung Jin Shin; Hyojune Kim; Dongjun Park; Erica Kholinne; In-Ho Jeon; Kyoung Hwan Koh
Journal:  Orthop J Sports Med       Date:  2020-09-28

Review 3.  Modern trabecular metal-backed glenoid components in total shoulder arthroplasty: What is the evidence? A systematic review.

Authors:  Michael-Alexander Malahias; Dimitrios Chytas; Lazaros Kostretzis; Angelos Trellopoulos; Emmanouil Brilakis; Emmanouil Antonogiannakis
Journal:  Shoulder Elbow       Date:  2020-09-25

4.  Restoration of the joint geometry and outcome after stemless TESS shoulder arthroplasty.

Authors:  Lars V von Engelhardt; Michael Manzke; Andreas Breil-Wirth; Timm J Filler; Joerg Jerosch
Journal:  World J Orthop       Date:  2017-10-18

Review 5.  The Clinical Application of Porous Tantalum and Its New Development for Bone Tissue Engineering.

Authors:  Gan Huang; Shu-Ting Pan; Jia-Xuan Qiu
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

6.  Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid.

Authors:  Dong Min Kim; Mohammed Aldeghaither; Fahad Alabdullatif; Myung Jin Shin; Erica Kholinne; Hyojune Kim; In-Ho Jeon; Kyoung-Hwan Koh
Journal:  BMC Musculoskelet Disord       Date:  2020-02-21       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.