Literature DB >> 27565633

Comparison of handheld ultrasound and automated breast ultrasound in women recalled after mammography screening.

Roxanna Hellgren1,2, Paul Dickman2, Karin Leifland3, Ariel Saracco1, Per Hall2, Fuat Celebioglu4.   

Abstract

Background Automated breast volume scanner (ABVS) is an ultrasound (US) device with a wide scanner that sweeps over a large area of the breast and the acquired transverse images are sent to a workstation for reconstruction and review. Whether ABVS is as reliable as handheld US is, however, still not established. Purpose To compare the sensitivity and specificity of ABVS to handheld breast US for detection of breast cancer, in the situation of recall after mammography screening. Material and Methods A total of 113 women, five with bilateral suspicious findings, undergoing handheld breast US due to a suspicious mammographic finding in screening, underwent additional ABVS. The methods were assessed for each breast and each detected lesion separately and classified into two categories: breasts with mammographic suspicion of malignancy and breasts with a negative mammogram. Results Twenty-six cancers were found in 25 women. In the category of breasts with a suspicious mammographic finding (n = 118), the sensitivity of both handheld US and ABVS was 88% (22/25). The specificity of handheld US was 93.5% (87/93) and ABVS was 89.2% (83/93). In the category of breasts with a negative mammography (n = 103), the sensitivity of handheld US and ABVS was 100% (1/1). The specificity of handheld US was 100% (102/102) and ABVS was 94.1% (96/102). Conclusion ABVS can potentially replace handheld US in the investigation of women recalled from mammography screening due to a suspicious finding. Due to the small size of our study population, further investigation with larger study populations is necessary before the implementation of such practice.

Entities:  

Keywords:  Breast; mammography; primary neoplasms; ultrasound

Mesh:

Year:  2016        PMID: 27565633     DOI: 10.1177/0284185116665421

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  The Role of ABUS in The Diagnosis of Breast Cancer.

Authors:  Elżbieta Łuczyńska; Marta Pawlak; Tadeusz Popiela; Wojciech Rudnicki
Journal:  J Ultrason       Date:  2022-04-27

Review 2.  Evaluation of Diagnostic Performance of Automatic Breast Volume Scanner Compared to Handheld Ultrasound on Different Breast Lesions: A Systematic Review.

Authors:  Shahad A Ibraheem; Rozi Mahmud; Suraini Mohamad Saini; Hasyma Abu Hassan; Aysar Sabah Keiteb; Ahmed M Dirie
Journal:  Diagnostics (Basel)       Date:  2022-02-19

3.  Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a meta-analysis.

Authors:  Xiaohui Zhang; Juan Chen; Yidong Zhou; Feng Mao; Yan Lin; Songjie Shen; Qiang Sun; Zhaolian Ouyang
Journal:  Gland Surg       Date:  2019-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.