John S M Chang1, Vincent K C Chan1, Jack C M Ng1, Antony K P Law1.
Abstract
Background. The vision with diffractive toric multifocal intraocular lenses after cataract surgery in long eyes has not been studied previously. Objectives. To report visual performance after bilateral implantation of a diffractive toric multifocal intraocular lens in high myopes. Methods. Prospective, observational case series to include patients with axial length of ≥26 mm and corneal astigmatism of >1 dioptre who underwent bilateral AT LISA 909M implantation. Postoperative examinations included photopic and mesopic distance, intermediate, and near visual acuity; photopic contrast sensitivity; visual symptoms (0-5); satisfaction (1-5); and spectacle independence rate. Results. Twenty-eight eyes (14 patients) were included. Postoperatively, mean photopic monocular uncorrected distance, intermediate, and near visual acuities (logMAR) were 0.12 ± 0.20 (standard deviation), 0.24 ± 0.16, and 0.29 ± 0.21, respectively. Corresponding binocular values were -0.01 ± 0.14, 0.13 ± 0.12, and 0.20 ± 0.19, respectively. One eye (4%) had one-line loss in vision. Under mesopic condition, intermediate vision and near vision decreased significantly (all P ≤ 0.001). Contrast sensitivity at all spatial frequencies did not improve significantly under binocular condition (all P > 0.05). Median scores for halos, night glare, starbursts, and satisfaction were 0.50, 0.00, 0.00, and 4.25, respectively. Ten patients (71%) reported complete spectacle independence. Conclusions. Bilateral implantation of the intraocular lens in high myopes appeared to be safe and achieved good visual performance and high satisfaction.Entities:
Year: 2016 PMID: 27563460 PMCID: PMC4985582 DOI: 10.1155/2016/5320105
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Preoperative demographics and characteristics.
| Parameter | Mean ± SD | Range |
|---|---|---|
| Number of men (%) | 3 (21) | |
| Age (years) | 48.2 ± 6.7 | 35, 62 |
| Axial length (mm) | 29.16 ± 2.71 | 26.09, 33.90 |
| Anterior chamber depth (mm) | 3.39 ± 0.28 | 2.84, 3.98 |
| Average keratometry (D) | 45.13 ± 1.86 | 42.06, 49.36 |
| Corneal astigmatism (D) | 2.31 ± 0.86 | 1.13, 4.72 |
| Corrected distance visual acuity (logarithm of the minimum angle of resolution) | 0.20 ± 0.22 | −0.12, 0.60 |
| Sphere (D) | −16.87 ± 6.72 | −31.00, −8.25 |
| Cylinder (D) | 1.83 ± 1.22 | 0.00, 4.25 |
| Manifest refraction spherical equivalent (D) | −15.95 ± 6.94 | −31.00, −7.13 |
| IOL sphere (D) | 1.93 ± 5.71 | −8.0, 9.5 |
| IOL cylinder (D) | 3.34 ± 1.08 | 2.0, 6.0 |
D, dioptre; IOL, intraocular lens.
Figure 1Refractive and visual outcomes (CDVA, corrected distance visual acuity; D, dioptre; MRSE, manifest refraction spherical equivalent; Postop., postoperative; Preop., preoperative; SD, standard deviation; SIA, surgically induced astigmatism; TIA, target induced astigmatism; UDVA, uncorrected distance visual acuity).
Monocular visual acuity at the last visit (28 eyes).
| Parameter | Mean Snellen equivalent | Mean ± SD (logMAR) | Range (logMAR) | 20/40 or better, | 20/25 or better, |
|
|---|---|---|---|---|---|---|
|
| ||||||
| Photopic UDVA | 20/26 | 0.12 ± 0.20 | −0.12, 0.54 | 24 (86) | 17 (61) | 0.379 |
| Mesopic UDVA | 20/27 | 0.12 ± 0.20 | −0.12, 0.60 | 26 (93) | 16 (57) | |
| Photopic CDVA | 20/19 | −0.02 ± 0.13 | −0.12, 0.30 | 28 (100) | 26 (93) | 1.000 |
| Mesopic CDVA | 20/19 | −0.02 ± 0.13 | −0.12, 0.30 | 28 (100) | 26 (93) | |
|
| ||||||
| Photopic UIVA | 20/35 | 0.24 ± 0.16 | −0.03, 0.57 | 18 (64) | 7 (25) | <0.001 |
| Mesopic UIVA† | 20/45 | 0.35 ± 0.14 | 0.05, 0.57 | 9 (35) | 1 (4) | |
| Photopic DCIVA | 20/39 | 0.29 ± 0.14 | 0.07, 0.57 | 15 (54) | 4 (14) | <0.001 |
| Mesopic DCIVA† | 20/56 | 0.44 ± 0.13 | 0.23, 0.67 | 4 (15) | 0 (0) | |
|
| ||||||
| Photopic UNVA | 20/39 | 0.29 ± 0.21 | 0.02, 0.84 | 19 (68) | 3 (11) | <0.001 |
| Mesopic UNVA† | 20/50 | 0.39 ± 0.19 | 0.12, 0.92 | 10 (39) | 0 (0) | |
| Photopic DCNVA | 20/35 | 0.24 ± 0.19 | 0.02, 0.74 | 20 (71) | 7 (25) | <0.001 |
| Mesopic DCNVA† | 20/46 | 0.37 ± 0.19 | 0.14, 0.86 | 11 (42) | 0 (0) |
Comparison between the mean photopic and mesopic values.
†Data on 26 eyes are available.
CDVA, corrected distance visual acuity; DCIVA, distance-corrected intermediate visual acuity; DCNVA, distance-corrected near visual acuity; logMAR, logarithm of the minimum angle of resolution; UDVA, uncorrected distance visual acuity; UIVA, uncorrected intermediate visual acuity; UNVA, uncorrected near visual acuity.
Binocular visual acuity at the last visit (14 patients).
| Parameter | Mean Snellen equivalent | Mean ± SD (logMAR) | Range (logMAR) | 20/40 or better, | 20/25 or better, |
|
|---|---|---|---|---|---|---|
|
| ||||||
| Photopic UDVA | 20/20 | −0.01 ± 0.14 | −0.12, 0.30 | 14 (100) | 12 (86) | 0.043 |
| Mesopic UDVA | 20/21 | 0.02 ± 0.16 | −0.12, 0.30 | 14 (100) | 11 (79) | |
| Photopic CDVA | 20/18 | −0.03 ± 0.12 | −0.12, 0.30 | 14 (100) | 13 (93) | 1.000 |
| Mesopic CDVA | 20/18 | −0.03 ± 0.12 | −0.12, 0.30 | 14 (100) | 13 (93) | |
|
| ||||||
| Photopic UIVA | 20/27 | 0.13 ± 0.12 | −0.03, 0.31 | 12 (86) | 8 (57) | 0.001 |
| Mesopic UIVA† | 20/36 | 0.26 ± 0.13 | 0.03, 0.47 | 9 (69) | 1 (8) | |
| Photopic DCIVA | 20/33 | 0.21 ± 0.18 | −0.03, 0.53 | 19 (71) | 5 (36) | 0.001 |
| Mesopic DCIVA† | 20/45 | 0.35 ± 0.13 | 0.17, 0.61 | 6 (46) | 0 (0) | |
|
| ||||||
| Photopic UNVA | 20/32 | 0.20 ± 0.19 | 0.02, 0.76 | 12 (86) | 5 (36) | <0.001 |
| Mesopic UNVA† | 20/40 | 0.30 ± 0.17 | 0.12, 0.80 | 8 (62) | 0 (0) | |
| Photopic DCNVA | 20/30 | 0.18 ± 0.18 | 0.02, 0.72 | 12 (86) | 5 (36) | 0.001 |
| Mesopic DCNVA† | 20/38 | 0.28 ± 0.18 | 0.12, 0.82 | 10 (77) | 0 (0) |
Comparison between the mean photopic and mesopic values.
†Data on 13 patients are available.
CDVA, corrected distance visual acuity; DCIVA, distance-corrected intermediate visual acuity; DCNVA, distance-corrected near visual acuity; logMAR, logarithm of the minimum angle of resolution; UDVA, uncorrected distance visual acuity; UIVA, uncorrected intermediate visual acuity; UNVA, uncorrected near visual acuity.
Figure 2Binocular uncorrected distance, intermediate, and near visual acuity under photopic and mesopic condition at the last visit.
Figure 3Vectorial displays (single-polar plots) for the target induced astigmatism, surgically induced astigmatism, difference vector, and correction index.
Vectorial analysis at the last visit (28 eyes).
| Parameter | Arithmetic mean ± SD | Range | Vector mean | Geometric mean |
|---|---|---|---|---|
| Target induced astigmatism (D) | 2.19 ± 0.85 | 0.92, 4.27 | 0.89 × 0.58 | — |
| Surgically induced astigmatism (D) | 2.64 ± 0.98 | 1.11, 4.80 | 1.06 × 0.80 | — |
| Difference vector (D) | 0.67 ± 0.54 | 0.02, 2.21 | 0.54 × 0.55 | — |
| Magnitude of error (D) | 0.45 ± 0.50 | −0.21, 2.15 | — | — |
| Angle of error (degrees) | −2.15 ± 8.25 | −36.69, 6.79 | — | — |
| Absolute angle of error (degrees) | 4.78 ± 7.02 | 0.00, 36.69 | — | — |
| Correction index | 1.23 ± 0.23 | 0.92, 1.81 | — | 1.22 |
| Index of success | 0.34 ± 0.29 | 0.01, 1.29 | — | 0.28 |
D, dioptre.
Figure 4Mean monocular (squares) and binocular (crosses) contrast sensitivity at different spatial frequencies for the 909M in eyes with a long axial length in the current study and 909M in eyes with an average axial length (monocular) (stars, data from Visser et al. [14]) with a population norm of 20 to 55 years old (monocular) (diamonds, data from VectorVision [38]) and 50 to 75 years old (monocular) (triangles, data from Pomerance and Evans [39] and VectorVision [38]) (∗ indicates a significant difference in mean monocular contrast sensitivity between eyes with a long axial length implanted with the 909M in the current study and the population norm of 20 to 55 years old (monocular); † indicates a significant difference in mean monocular contrast sensitivity between eyes with a long axial length implanted with the 909M in the current study and the population norm of 50 to 75 years old (monocular)).
Results of questionnaire at the last visit (14 patients).
| Parameter | Mean ± SD | Median | Range |
|---|---|---|---|
|
| |||
| Halo | 0.82 ± 0.99 | 0.50 | 0.0, 3.0 |
| Night glare | 0.61 ± 0.90 | 0.00 | 0.0, 2.5 |
| Starbursts | 0.43 ± 0.76 | 0.00 | 0.0, 2.0 |
|
| |||
| Distance | 4.64 ± 0.36 | 4.50 | 4.0, 5.0 |
| Intermediate | 3.57 ± 1.34 | 4.00 | 0.5, 5.0 |
| Near | 4.46 ± 0.50 | 4.50 | 3.5, 5.0 |
|
| 4.39 ± 0.53 | 4.25 | 3.5, 5.0 |
|
| 0 (0) | ||
|
| 13 (93) | ||
|
| |||
| Distance tasks | 14 (100) | ||
| Intermediate tasks | 12 (86) | ||
| Near tasks | 11 (79) | ||
| Any distances | 10 (71) | ||
†Level of visual symptoms (0, none; 1, very mild; 2, mild; 3, moderate; 4, severe; 5, very severe).
‡Vision rating (1, very blurry; 2, blurry; 3, fair; 4, clear; 5, very clear).
§Level of satisfaction (1, very dissatisfied; 2, dissatisfied; 3, neutral; 4, satisfied; 5, very satisfied).