Literature DB >> 27561748

Refractive results of phacoemulsification in vitrectomized patients.

Jia-Kang Wang1,2,3,4,5,6, Shu-Wen Chang7,8.   

Abstract

The aim of this study was to compare the refractive errors after uneventful phacoemulsification and intraocular lens implantation in the cases of vitrectomized eyes and non-vitrectomized eyes. Vitrectomized eyes were divided into 2 groups: vitrectomy alone as Group 1, vitrectomy with gas tamponade as Group 2. Normal-controlled eyes were categorized as Group 3. Intraocular lens (IOL) power calculation and the measurements of axial length (AL) and keratometric value (K) were performed using the IOLMaster and the Haigis and SRK/T formula as subgroup A and B. The measurements of AL, K, and IOL power calculation were also performed by the applanation ultrasound and the SRK/T formula as comparison subgroup C. The mean numeric error (MNE) and median absolute error (MedAE) were compared between Groups and subgroups. The MedAE was not significantly different in Group 1A, 2A, and 3A, respectively (p > 0.05). The MNE was significantly different in Group 1A, 2A, and 3A (p = 0.04). Post hoc test showed an insignificant difference between Group 1A and 3A (p = 0.36), but significantly a higher MNE in Group 2A than that in Group 3A (p = 0.03). A significantly longer AL was noted in Group 1B and 2B, comparing with Group 1C and 2C (p < 0.01). Refractive outcomes after phacoemulsification sequential to vitrectomy alone were comparable to those in normal control. Hyperopic shift was found following phacoemulsification sequential to vitrectomy with gas tamponade comparing to normal eyes. A significantly longer AL was found using optical biometry compared to applanation ultrasound in vitrectomized eyes, but not in normal eyes.

Entities:  

Keywords:  Applanation ultrasound; Axial length; Cataract; Gas tamponade; Intraocular lens power; Optical biometry; Phacoemulsification; The Haigis formula; The IOLMaster; Vitrectomy

Mesh:

Year:  2016        PMID: 27561748     DOI: 10.1007/s10792-016-0325-1

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  39 in total

1.  Alterations in the corneal topography after pars plana vitrectomy with the standard system of 20-gauge and the 25-gauge transconjunctival sutureless vitrectomy.

Authors:  Alcio Coutinho de Paula; João Jorge Nassaralla Júnior; Francisco Weliton Rodrigues; Rodrigo Egídio da Silva; Rodrigo Salustiano Correa e Silva; David Roberto Barbosa Junior
Journal:  Semin Ophthalmol       Date:  2012 Jan-Mar       Impact factor: 1.975

2.  Change in anterior chamber depth following combined pars plana vitrectomy, phacoemulsification, and intraocular lens implantation using different types of intraocular lenses.

Authors:  Akira Watanabe; Tomohiro Shibata; Miho Ozaki; Kiichirou Okano; Kenichi Kozaki; Hiroshi Tsuneoka
Journal:  Jpn J Ophthalmol       Date:  2010-11-05       Impact factor: 2.447

3.  Intraocular lens power calculation for combined cataract surgery, vitrectomy and peeling of epiretinal membranes for macular oedema.

Authors:  Illés Kovács; Mária Ferencz; János Nemes; Gábor Somfai; György Salacz; Zsuzsa Récsán
Journal:  Acta Ophthalmol Scand       Date:  2007-02

4.  Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length.

Authors:  Jia-Kang Wang; Chao-Yu Hu; Shu-Wen Chang
Journal:  J Cataract Refract Surg       Date:  2008-02       Impact factor: 3.351

5.  Refractive outcomes of phacoemulsification and intraocular lens implantation after pars plana vitrectomy.

Authors:  Na Young Lee; Shin Hae Park; Choun Ki Joo
Journal:  Retina       Date:  2009-04       Impact factor: 4.256

6.  Phacoemulsification in eyes with past pars plana vitrectomy: case-control study.

Authors:  S M Pinter; A Sugar
Journal:  J Cataract Refract Surg       Date:  1999-04       Impact factor: 3.351

7.  Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation.

Authors:  János Németh; Orsolya Fekete; Norbert Pesztenlehrer
Journal:  J Cataract Refract Surg       Date:  2003-01       Impact factor: 3.351

Review 8.  Cataract surgery after pars plana vitrectomy.

Authors:  Mohamed Abou Shousha; Sonia H Yoo
Journal:  Curr Opin Ophthalmol       Date:  2010-01       Impact factor: 3.761

9.  Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

Authors:  W Haigis; B Lege; N Miller; B Schneider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-09       Impact factor: 3.117

10.  Intraocular lens power calculation using IOLMaster and various formulas in short eyes.

Authors:  Young Rae Roh; Sang Mok Lee; Young Keun Han; Mee Kum Kim; Won Ryang Wee; Jin Hak Lee
Journal:  Korean J Ophthalmol       Date:  2011-05-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.