Literature DB >> 27556274

Determination of Glomerular Filtration Rate with CT Measurement of Renal Clearance of Iodinated Contrast Material versus 99mTc-DTPA Dynamic Imaging "Gates" Method: A Validation Study in Asymmetrical Renal Disease.

XiaoDong Yuan1, Jing Zhang1, Ke Tang1, ChangBin Quan1, Yuan Tian1, Hong Li1, GuoKun Ao1, Liheng Qiu1.   

Abstract

Purpose To validate a computed tomographic (CT) glomerular filtration rate (GFR) measurement and compare it with renal dynamic imaging GFR obtained by using the "Gates" method, with dual plasma sampling technetium 99m (99mTc) diethylenetriaminepenta-acetic acid (DTPA) clearance ("true GFR") as the reference standard. Materials and Methods This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Forty-two patients with unilateral renal disease were included. Single-kidney CT GFR was calculated as excretory phase whole-kidney CT number enhancement divided by the area under the time-attenuation curve for the aorta, multiplied by (1 - hematocrit level). The CT GFR was then obtained by summing the result of the two sides. The true GFR and the Gates GFR were measured by using a single injection of 99mTc-DTPA. The CT GFR and Gates GFR were respectively compared with the true GFR by using a paired t test and linear regression analysis. Results The difference between CT GFR (mean ± standard deviation, 96.02 mL/min ± 23.11) and true GFR (90.50 mL/min ± 21.46) was 5.51 mL/min ± 6.96 (P < .001), demonstrating 6.09% systemic overestimation. The difference between Gates GFR (93.93 mL/min ± 26.97) and true GFR was 3.42 mL/min ± 16.10 (P = .176). Linear regression findings confirmed the association between CT GFR (y-axis) and true GFR (x-axis) and between Gates GFR (y-axis) and true GFR (x-axis) (P < .001 for both). Both regression lines paralleled the diagonal (intercept = 0 and slope = 1) (P = .599 and P = .945, respectively). The 95% confidence interval of the former was above the diagonal, confirming the systemic overestimation. The standard deviations of residuals of both linear regressions were 7.02 mL/min and 16.30 mL/min, respectively, demonstrating smaller deviation of the CT GFR (P < .001). Conclusion The proposed CT GFR measurement was validated in this study and was proved to be more accurate than the Gates method despite slight (6.09%) systemic overestimation. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27556274     DOI: 10.1148/radiol.2016160425

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Determination of glomerular filtration rate (GFR) from fractional renal accumulation of iodinated contrast material: a convenient and rapid single-kidney CT-GFR technique.

Authors:  XiaoDong Yuan; Wei Tang; WenWei Shi; Libao Yu; Jing Zhang; Qing Yuan; Shan You; Ning Wu; Guokun Ao; Tingting Ma
Journal:  Eur Radiol       Date:  2018-02-09       Impact factor: 5.315

2.  Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method.

Authors:  Shan You; XianWu Ma; ChangZhu Zhang; Qiang Li; WenWei Shi; Jing Zhang; XiaoDong Yuan
Journal:  Eur Radiol       Date:  2017-10-02       Impact factor: 5.315

3.  The Delayed Nephrogram: Point-of-care Quantitative Measurement, Validation as an Indicator of Obstruction, and Novel Use as a Predictor of Renal Functional Impairment.

Authors:  Marshall C Strother; Eric Y Cho; Matt Loecher; David Strauss; Akhil Chandra; Elizabeth Handorf; Jian Yu; David Y T Chen; Robert Uzzo; Laura Levin; Jordan Anaokar; Alexander Kutikov
Journal:  Eur Urol Focus       Date:  2022-02-15

4.  SUDOSCAN, an effective tool for screening chronic kidney disease in patients with type 2 diabetes.

Authors:  Fei Mao; Siying Liu; Xiaona Qiao; Hangping Zheng; Qian Xiong; Jie Wen; Shuo Zhang; Zhaoyun Zhang; Hongying Ye; Hongli Shi; Bin Lu; Yiming Li
Journal:  Exp Ther Med       Date:  2017-06-27       Impact factor: 2.447

5.  Measurement of Glomerular Filtration Rate Using Multiphasic Computed Tomography in Patients With Unilateral Renal Tumors: A Feasibility Study.

Authors:  Tingting Wang; Yi Xu; Wangyan Liu; Pengfei Shao; Qiang Lv; Guanyu Yang; Lijun Tang
Journal:  Front Physiol       Date:  2019-09-19       Impact factor: 4.566

6.  Noninvasive monitoring of chronic kidney disease using pH and perfusion imaging.

Authors:  KowsalyaDevi Pavuluri; Irini Manoli; Alexandra Pass; Yuguo Li; Hilary J Vernon; Charles P Venditti; Michael T McMahon
Journal:  Sci Adv       Date:  2019-08-14       Impact factor: 14.136

Review 7.  Present Situation and Research Progress of Kidney Function Recoverability Evaluation of Acute Kidney Injury Patient.

Authors:  Yu-Long Yao; Yuan Gao
Journal:  Int J Gen Med       Date:  2021-05-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.