Literature DB >> 27551879

Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

Antonio Scarano1, Luca Valbonetti, Marco Degidi, Raffaella Pecci, Adriano Piattelli, P S de Oliveira, Vittoria Perrotti.   

Abstract

PURPOSE: The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections.
MATERIALS AND METHODS: A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV).
RESULTS: In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present.
CONCLUSIONS: The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

Entities:  

Mesh:

Year:  2016        PMID: 27551879     DOI: 10.1097/ID.0000000000000465

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  7 in total

Review 1.  Histological and Biological Response to Different Types of Biomaterials: A Narrative Single Research Center Experience over Three Decades.

Authors:  Margherita Tumedei; Eitan Mijiritsky; Carlos Fernando Mourão; Adriano Piattelli; Marco Degidi; Carlo Mangano; Giovanna Iezzi
Journal:  Int J Environ Res Public Health       Date:  2022-06-28       Impact factor: 4.614

2.  Oral bacterial colonization on dental implants restored with titanium or zirconia abutments: 6-month follow-up.

Authors:  Alice Ramos de Freitas; Thalisson Saymo de Oliveira Silva; Ricardo Faria Ribeiro; Rubens Ferreira de Albuquerque Junior; Vinícius Pedrazzi; Cássio do Nascimento
Journal:  Clin Oral Investig       Date:  2018-01-18       Impact factor: 3.573

3.  The influence of implant-abutment connection on the screw loosening and microleakage.

Authors:  Katsuhiro Tsuruta; Yasunori Ayukawa; Tatsuya Matsuzaki; Masafumi Kihara; Kiyoshi Koyano
Journal:  Int J Implant Dent       Date:  2018-04-09

4.  A New Strategy Against Peri-Implantitis: Antibacterial Internal Coating.

Authors:  Francesco Carinci; Dorina Lauritano; Carlo Alberto Bignozzi; Daniele Pazzi; Valentina Candotto; Paulo Santos de Oliveira; Antonio Scarano
Journal:  Int J Mol Sci       Date:  2019-08-09       Impact factor: 5.923

5.  One-Piece Titanium Implants: Retrospective Case Series.

Authors:  Gunar Wagner; Dieter Hartung
Journal:  Case Rep Dent       Date:  2021-04-08

6.  Mechanical Pull-Out Test of a New Hybrid Fixture-Abutment Connection: An In Vitro Study.

Authors:  Gianmaria D'Addazio; Bruna Sinjari; Lorenzo Arcuri; Beatrice Femminella; Giovanna Murmura; Manlio Santilli; Sergio Caputi
Journal:  Materials (Basel)       Date:  2021-03-22       Impact factor: 3.623

7.  Direct-Deposited Graphene Oxide on Dental Implants for Antimicrobial Activities and Osteogenesis.

Authors:  WooHyung Jang; Hee-Seon Kim; Khurshed Alam; Min-Kyung Ji; Hoon-Sung Cho; Hyun-Pil Lim
Journal:  Int J Nanomedicine       Date:  2021-08-24
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.