Literature DB >> 27551341

Free-breathing radial volumetric interpolated breath-hold examination vs breath-hold cartesian volumetric interpolated breath-hold examination magnetic resonance imaging of the liver at 1.5T.

Sireesha Yedururi1, HyunSeon C Kang1, Wei Wei1, Nicolaus A Wagner-Bartak1, Leonardo P Marcal1, R Jason Stafford1, Brandy J Willis1, Janio Szklaruk1.   

Abstract

AIM: To compare breath-hold cartesian volumetric interpolated breath-hold examination (cVIBE) and free-breathing radial VIBE (rVIBE) and determine whether rVIBE could replace cVIBE in routine liver magnetic resonance imaging (MRI).
METHODS: In this prospective study, 15 consecutive patients scheduled for routine MRI of the abdomen underwent pre- and post-contrast breath-hold cVIBE imaging (19 s acquisition time) and free-breathing rVIBE imaging (111 s acquisition time) on a 1.5T Siemens scanner. Three radiologists with 2, 4, and 8 years post-fellowship experience in abdominal imaging evaluated all images. The radiologists were blinded to the sequence types, which were presented in a random order for each patient. For each sequence, the radiologists scored the cVIBE and rVIBE images for liver edge sharpness, hepatic vessel clarity, presence of artifacts, lesion conspicuity, fat saturation, and overall image quality using a five-point scale.
RESULTS: Compared to rVIBE, cVIBE yielded significantly (P < 0.001) higher scores for liver edge sharpness (mean score, 3.87 vs 3.37), hepatic-vessel clarity (3.71 vs 3.18), artifacts (3.74 vs 3.06), lesion conspicuity (3.81 vs 3.2), and overall image quality (3.91 vs 3.24). cVIBE and rVIBE did not significantly differ in quality of fat saturation (4.12 vs 4.03, P = 0.17). The inter-observer variability with respect to differences between rVIBE and cVIBE scores was close to zero compared to random error and inter-patient variation. Quality of rVIBE images was rated as acceptable for all parameters.
CONCLUSION: rVIBE cannot replace cVIBE in routine liver MRI. At 1.5T, free-breathing rVIBE yields acceptable, although slightly inferior image quality compared to breath-hold cVIBE.

Entities:  

Keywords:  Free-breathing magnetic resonance acquisition; Liver magnetic resonance imaging; Radial imaging

Year:  2016        PMID: 27551341      PMCID: PMC4965355          DOI: 10.4329/wjr.v8.i7.707

Source DB:  PubMed          Journal:  World J Radiol        ISSN: 1949-8470


  13 in total

1.  Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging.

Authors:  S Shimizu; H Shirato; B Xo; K Kagei; T Nishioka; S Hashimoto; K Tsuchiya; H Aoyama; K Miyasaka
Journal:  Radiother Oncol       Date:  1999-03       Impact factor: 6.280

2.  Segmented k-space and real-time cardiac cine MR imaging with radial trajectories.

Authors:  A Shankaranarayanan; O P Simonetti; G Laub; J S Lewin; J L Duerk
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

3.  Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution.

Authors:  Hee Kwon Song; Lawrence Dougherty
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

4.  Noncontrast-enhanced three-dimensional magnetic resonance aortography of the thorax at 3.0 T using respiratory-compensated T1-weighted k-space segmented gradient-echo imaging with radial data sampling: preliminary study.

Authors:  Yasuo Amano; Katsuya Takahama; Shinichiro Kumita
Journal:  Invest Radiol       Date:  2009-09       Impact factor: 6.016

5.  Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC).

Authors:  Kyung Won Kim; Jeong Min Lee; Yong Sik Jeon; Sung Eun Kang; Jee Hyun Baek; Joon Koo Han; Byung Ihn Choi; Yung-Jue Bang; Berthold Kiefer; Kai Tobias Block; Hyunjun Ji; Simon Bauer; Chin Kim
Journal:  Eur Radiol       Date:  2012-11-28       Impact factor: 5.315

6.  Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase.

Authors:  Yasunari Fujinaga; Ayumi Ohya; Hirokazu Tokoro; Akira Yamada; Kazuhiko Ueda; Hitoshi Ueda; Yoshihiro Kitou; Yasuo Adachi; Aya Shiobara; Naomichi Tamaru; Marcel D Nickel; Katsuya Maruyama; Masumi Kadoya
Journal:  Eur Radiol       Date:  2014-03-15       Impact factor: 5.315

7.  Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.

Authors:  Hersh Chandarana; Tobias K Block; Andrew B Rosenkrantz; Ruth P Lim; Danny Kim; David J Mossa; James S Babb; Berthold Kiefer; Vivian S Lee
Journal:  Invest Radiol       Date:  2011-10       Impact factor: 6.016

8.  Cranio-caudal movements of the liver, pancreas and kidneys in respiration.

Authors:  I Suramo; M Päivänsalo; V Myllylä
Journal:  Acta Radiol Diagn (Stockh)       Date:  1984

9.  Free breathing three-dimensional gradient echo-sequence with radial data sampling (radial 3D-GRE) examination of the pancreas: Comparison with standard 3D-GRE volumetric interpolated breathhold examination (VIBE).

Authors:  Saraporn Bamrungchart; Engy M Tantaway; Esin C Midia; Mateus A Hernandes; Saowanee Srirattanapong; Brian M Dale; Richard C Semelka
Journal:  J Magn Reson Imaging       Date:  2013-02-15       Impact factor: 4.813

10.  Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI.

Authors:  Hersh Chandarana; Kai T Block; Matthew J Winfeld; Shailee V Lala; Daniel Mazori; Emalyn Giuffrida; James S Babb; Sarah S Milla
Journal:  Eur Radiol       Date:  2013-09-25       Impact factor: 5.315

View more
  4 in total

1.  With 3 Types of Respiratory Acquisition: 3.0 T Respiratory Triggered Acquisition Can Obtain Higher Quality DWI Images of the Upper Abdomen.

Authors:  Zhuo Shi; Jiuming Jiang; Han Ouyang; Lizhi Xie; Xinming Zhao
Journal:  Contrast Media Mol Imaging       Date:  2022-07-09       Impact factor: 3.009

2.  Feasibility of pulmonary MRI for nodule detection in comparison to computed tomography.

Authors:  Nan Yu; Chuangbo Yang; Guangming Ma; Shan Dang; Zhanli Ren; Shaoyu Wang; Yong Yu
Journal:  BMC Med Imaging       Date:  2020-05-20       Impact factor: 1.930

3.  Free-breathing radial 3D fat-suppressed T1-weighted gradient echo (r-VIBE) sequence for assessment of pulmonary lesions: a prospective comparison of CT and MRI.

Authors:  Nan Yu; Haifeng Duan; Chuangbo Yang; Yong Yu; Shan Dang
Journal:  Cancer Imaging       Date:  2021-12-20       Impact factor: 3.909

4.  Feasibility of quantitative susceptibility mapping (QSM) of the human kidney.

Authors:  Eric Bechler; Julia Stabinska; Thomas Thiel; Jonas Jasse; Romans Zukovs; Birte Valentin; Hans-Jörg Wittsack; Alexandra Ljimani
Journal:  MAGMA       Date:  2020-11-24       Impact factor: 2.310

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.