Literature DB >> 10392824

Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging.

S Shimizu1, H Shirato, B Xo, K Kagei, T Nishioka, S Hashimoto, K Tsuchiya, H Aoyama, K Miyasaka.   

Abstract

OBJECTIVE: Three-dimensional (3D) movement of a spherical liver tumor during respiration was investigated with magnetic resonance imaging (MRI) using a high-speed sequence.
METHODS: A marker was placed on the surface of the patient as a reference of distance. Repetition time (TR) was 7.7 ms, echo time (TE) was 4.2 ms, flip angle was 20 degrees, section thickness was 8 mm, and a 256 x 128 matrix was used. The acquisition time was 1.0 s followed by an interval of 0.5 s. The 20 tumor contours extracted during 30 s were superimposed on sagittal and coronal MR images.
RESULTS: The maximum value of tumor edge location was 3.9 cm in the cranio-caudal direction, 2.3 cm in the ventro-dorsal direction, and 3.1 cm in the lateral direction. The mean length of tumor displacement observed was 2.1 cm in the cranio-caudal direction, 0.8 cm in the ventro-dorsal and 0.9 cm in the left-right direction, respectively. The locus of the center of the tumor contour in the sagittal cross section was inclined at 23 degrees and in the coronal cross section was inclined at 18 degrees to the cranio-caudal axis of body.
CONCLUSION: In conclusion, 3D movement of a spherical liver tumor was detected using rapid MRI sequential examinations. Magnetic resonance imaging has a potential to improve the accuracy of the planning target volume of a liver tumor.

Entities:  

Mesh:

Year:  1999        PMID: 10392824     DOI: 10.1016/s0167-8140(98)00140-6

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  23 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

Review 2.  Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy.

Authors:  Hiroki Shirato; Shinichi Shimizu; Kei Kitamura; Rikiya Onimaru
Journal:  Int J Clin Oncol       Date:  2007-02-25       Impact factor: 3.402

3.  Concepts and preliminary data toward the realization of image-guided liver surgery.

Authors:  David M Cash; Michael I Miga; Sean C Glasgow; Benoit M Dawant; Logan W Clements; Zhujiang Cao; Robert L Galloway; William C Chapman
Journal:  J Gastrointest Surg       Date:  2007-07       Impact factor: 3.452

4.  Feasibility of diffusion-weighted imaging under split breath-hold acquisition and postprocessing (DWI-SBAP): an attempt to suppress hepatic pseudo-anisotropy.

Authors:  Katsuhiro Nasu; Yoshifumi Kuroki; Manabu Minami
Journal:  Jpn J Radiol       Date:  2009-03-12       Impact factor: 2.374

5.  Adaptive 4D MR imaging using navigator-based respiratory signal for MRI-guided therapy.

Authors:  Junichi Tokuda; Shigehiro Morikawa; Hasnine A Haque; Tetsuji Tsukamoto; Kiyoshi Matsumiya; Hongen Liao; Ken Masamune; Takeyoshi Dohi
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

6.  A 4D ultrasound real-time tracking system for external beam radiotherapy of upper abdominal lesions under breath-hold.

Authors:  Dwi Seno Kuncoro Sihono; Lena Vogel; Christel Weiß; Johannes Thölking; Frederik Wenz; Frank Lohr; Judit Boda-Heggemann; Hansjörg Wertz
Journal:  Strahlenther Onkol       Date:  2016-12-05       Impact factor: 3.621

Review 7.  Motion management in gastrointestinal cancers.

Authors:  Hassan Abbas; Bryan Chang; Zhe Jay Chen
Journal:  J Gastrointest Oncol       Date:  2014-06

8.  Serum-based tracking of de novo initiated liver cancer progression reveals early immunoregulation and response to therapy.

Authors:  Jeff J Subleski; Anthony J Scarzello; W Gregory Alvord; Qun Jiang; Jimmy K Stauffer; Anthony Kronfli; Bahara Saleh; Timothy Back; Jonathan M Weiss; Robert H Wiltrout
Journal:  J Hepatol       Date:  2015-07-02       Impact factor: 25.083

9.  Free-breathing radial volumetric interpolated breath-hold examination vs breath-hold cartesian volumetric interpolated breath-hold examination magnetic resonance imaging of the liver at 1.5T.

Authors:  Sireesha Yedururi; HyunSeon C Kang; Wei Wei; Nicolaus A Wagner-Bartak; Leonardo P Marcal; R Jason Stafford; Brandy J Willis; Janio Szklaruk
Journal:  World J Radiol       Date:  2016-07-28

10.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more