Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK.

Hua Li, Yan Wang, Rui Dou, Pinghui Wei, Jiamei Zhang, Wei Zhao, Liuyang Li.   

Abstract

PURPOSE: The purpose of this article was to evaluate intraocular pressure (IOP) changes and investigate the relationship with corneal biomechanics after small-incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK).
METHODS: A total of 193 eyes of 193 patients who underwent SMILE and FS-LASIK procedures were included in this retrospective study. Data were collected preoperatively and postoperatively, including Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), corneal hysteresis (CH), and corneal resistance factor (CRF) by ocular response analyzer, noncontact intraocular pressure (IOPNCT) by noncontact tonometer, and Ehlers, Shah, Dresden, Kohlhaas, Orssengo/Pye by the Pentacam corrected system. Changes in both groups and differences between groups were evaluated. Multiple linear regression models were constructed to explore factors influencing IOP changes.
RESULTS: In SMILE, the IOPg, IOPcc, IOPNCT, and Kohlhaas decreased significantly at 1 month postoperatively (P < 0.01), whereas with the Ehlers formula they significantly increased (P < 0.01). IOPs decreased at 3 and 6 months compared with all preoperative values except Ehlers values (P < 0.01), but there was no significant difference between 3 and 6 months (P > 0.05). In FS-LASIK, the IOPg, IOPcc, and IOPNCT decreased significantly at 1 month (P < 0.01), whereas in the Ehlers and Shah formulas they significantly increased (P < 0.01). Compared with preoperative values, the IOPs decreased at 3 and 6 months except in the Ehlers and Shah formulas (P < 0.01). Only IOPg and IOPcc differed between 3 and 6 months (P < 0.05). The Ehlers and Shah formulas were closer to the preoperative IOP for both groups, with variation approximately 1 mm Hg at 6 months postoperatively. Preoperative IOP, postoperative corneal resistance factor, corneal hysteresis, and flat keratometry were enrolled into the regression equations.
CONCLUSIONS: IOP underestimation after SMILE or FS-LASIK was related to corneal biomechanics as well as preoperative IOP and flat keratometry. IOP after SMILE seem to remain more stable. Accordingly, the Ehlers and Shah formulas were closer to the preoperative IOP. It may be useful to estimate future IOP with the best-fit models after surgery.

Entities:  

Mesh:

Year:  2016        PMID: 27548888     DOI: 10.1167/iovs.16-19615

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  14 in total

1.  Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer.

Authors:  Ahmed Yassin Hemida; Omar M Said; Asser A E Abdel-Meguid; Mohammed Iqbal; Amani E Badawi
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

2.  Clinical outcomes of small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a Meta-analysis.

Authors:  Huan Yan; Li-Yan Gong; Wei Huang; Yan-Li Peng
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

3.  Changes in Schlemm's canal, trabecular meshwork, and relevant parameters in the early stage after SMILE of myopia patients.

Authors:  Dan-Dan Yang; Zhi-Qi Chen; Wei Chen; He Yin; Jing-Kai Peng; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

4.  Comparison of visual results and higher-order aberrations after small incision lenticule extraction (SMILE): high myopia vs. mild to moderate myopia.

Authors:  Hong-Ying Jin; Ting Wan; Fang Wu; Ke Yao
Journal:  BMC Ophthalmol       Date:  2017-07-06       Impact factor: 2.209

5.  Corneal Biomechanical Properties after FS-LASIK with Residual Bed Thickness Less Than 50% of the Original Corneal Thickness.

Authors:  Haixia Zhang; Muhammad Ahmad Khan; Di Zhang; Xiao Qin; Ding Lin; Lin Li
Journal:  J Ophthalmol       Date:  2018-01-11       Impact factor: 1.909

Review 6.  Review of Corneal Biomechanical Properties Following LASIK and SMILE for Myopia and Myopic Astigmatism.

Authors:  Iben Bach Damgaard; Mohamed Reffat; Jesper Hjortdal
Journal:  Open Ophthalmol J       Date:  2018-07-27

7.  Study on change in corneal biomechanics and effect of percent tissue altered in myopic laser-assisted in situ keratomileusis.

Authors:  Murugesan Vanathi; Suresh Azimeera; Noopur Gupta; Radhika Tandon
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

8.  Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction.

Authors:  Mohamed Hosny; Fayrouz Aboalazayem; Hoda El Shiwy; Mohsen Salem
Journal:  Clin Ophthalmol       Date:  2017-07-14

9.  Corneal Cap Thickness and Its Effect on Visual Acuity and Corneal Biomechanics in Eyes Undergoing Small Incision Lenticule Extraction.

Authors:  Ting Liu; Ting Yu; Lina Liu; Kaijian Chen; Ji Bai
Journal:  J Ophthalmol       Date:  2018-06-28       Impact factor: 1.909

10.  Intraocular pressure changes and corneal biomechanics after hyperopic small-incision lenticule extraction.

Authors:  Dan Fu; Meiyan Li; Michael C Knorz; Shengsheng Wei; Jianmin Shang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2020-04-05       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.