Quantifying and Reducing Motion Artifacts in Wearable Seismocardiogram Measurements During Walking to Assess Left Ventricular Health.

Abdul Q Javaid, Hazar Ashouri, Alexis Dorier, Mozziyar Etemadi, J Alex Heller, Shuvo Roy, Omer T Inan.   

Abstract

GOAL: Our objective is to provide a framework for extracting signals of interest from the wearable seismocardiogram (SCG) measured during walking at normal (subject's preferred pace) and moderately fast (1.34-1.45 m/s) speeds.
METHODS: We demonstrate, using empirical mode decomposition (EMD) and feature tracking algorithms, that the pre-ejection period (PEP) can be accurately estimated from a wearable patch that simultaneously measures electrocardiogram and sternal acceleration signals. We also provide a method to determine the minimum number of heartbeats required for an accurate estimate to be obtained for the PEP from the accelerometer signals during walking.
RESULTS: The EMD-based denoising approach provides a statistically significant increase in the signal-to-noise ratio of wearable SCG signals and also improves estimation of PEP during walking.
CONCLUSION: The algorithms described in this paper can be used to provide hemodynamic assessment from wearable SCG during walking. SIGNIFICANCE: A major limitation in the use of the SCG, a measure of local chest vibrations caused by cardiac ejection of blood in the vasculature, is that a user must remain completely still for high-quality measurements. The motion can create artifacts and practically render the signal unreadable. Addressing this limitation could allow, for the first time, SCG measurements to be obtained reliably during movement-aside from increasing the coverage throughout the day of cardiovascular monitoring, analyzing SCG signals during movement would quantify the cardiovascular system's response to stress (exercise), and thus provide a more holistic assessment of overall health.

Entities:  

Mesh:

Year:  2016        PMID: 27541330      PMCID: PMC5444999          DOI: 10.1109/TBME.2016.2600945

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  20 in total

1.  Infrasonic cardiac signals: complementary windows to cardiovascular dynamics.

Authors:  Kouhyar Tavakolian; Brandon Ngai; Andrew P Blaber; Bozena Kaminska
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Accelerometer body sensor network improves systolic time interval assessment with wearable ballistocardiography.

Authors:  Andrew D Wiens; Omer T Inan
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2015

3.  Executive Summary: Heart Disease and Stroke Statistics--2016 Update: A Report From the American Heart Association.

Authors:  Dariush Mozaffarian; Emelia J Benjamin; Alan S Go; Donna K Arnett; Michael J Blaha; Mary Cushman; Sandeep R Das; Sarah de Ferranti; Jean-Pierre Després; Heather J Fullerton; Virginia J Howard; Mark D Huffman; Carmen R Isasi; Monik C Jiménez; Suzanne E Judd; Brett M Kissela; Judith H Lichtman; Lynda D Lisabeth; Simin Liu; Rachel H Mackey; David J Magid; Darren K McGuire; Emile R Mohler; Claudia S Moy; Paul Muntner; Michael E Mussolino; Khurram Nasir; Robert W Neumar; Graham Nichol; Latha Palaniappan; Dilip K Pandey; Mathew J Reeves; Carlos J Rodriguez; Wayne Rosamond; Paul D Sorlie; Joel Stein; Amytis Towfighi; Tanya N Turan; Salim S Virani; Daniel Woo; Robert W Yeh; Melanie B Turner
Journal:  Circulation       Date:  2016-01-26       Impact factor: 29.690

4.  Adaptive hydrostatic blood pressure calibration: development of a wearable, autonomous pulse wave velocity blood pressure monitor.

Authors:  Devin B McCombie; Phillip A Shaltis; Andrew T Reisner; H Asada
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

5.  Wearable seismocardiography.

Authors:  Paolo Castiglioni; Andrea Faini; Gianfranco Parati; Marco Di Rienzo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

6.  A critical review of the systolic time intervals.

Authors:  R P Lewis; S E Rittogers; W F Froester; H Boudoulas
Journal:  Circulation       Date:  1977-08       Impact factor: 29.690

7.  A novel system identification technique for improved wearable hemodynamics assessment.

Authors:  Andrew D Wiens; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2015-01-01       Impact factor: 4.538

8.  Validity and reliability of the 6-minute walk test in a cardiac rehabilitation population.

Authors:  D M Hamilton; R G Haennel
Journal:  J Cardiopulm Rehabil       Date:  2000 May-Jun       Impact factor: 2.081

9.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

10.  A study of systolic time intervals during uninterrupted exercise.

Authors:  G M Van Der Hoeven; P J Clerens; J J Donders; J E Beneken; J T Vonk
Journal:  Br Heart J       Date:  1977-03
View more
  21 in total

1.  Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings.

Authors:  Hazar Ashouri; Omer T Inan
Journal:  IEEE Sens J       Date:  2017-05-04       Impact factor: 3.301

2.  A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals.

Authors:  Jonathan Zia; Jacob Kimball; Sinan Hersek; Md Mobashir Hasan Shandhi; Beren Semiz; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-07-26       Impact factor: 5.772

3.  Precision wearable accelerometer contact microphones for longitudinal monitoring of mechano-acoustic cardiopulmonary signals.

Authors:  Pranav Gupta; Mohammad J Moghimi; Yaesuk Jeong; Divya Gupta; Omer T Inan; Farrokh Ayazi
Journal:  NPJ Digit Med       Date:  2020-02-12

Review 4.  Wearable ballistocardiogram and seismocardiogram systems for health and performance.

Authors:  Mozziyar Etemadi; Omer T Inan
Journal:  J Appl Physiol (1985)       Date:  2017-08-10

5.  The evaluation of seismocardiogram signal pre-processing using hybridized variational mode decomposition method.

Authors:  Miftah Pramudyo; Tati Latifah Erawati Rajab; Agung Wahyu Setiawan; Trio Adiono; Dziban Naufal
Journal:  Biomed Eng Lett       Date:  2022-06-06

6.  Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

Authors:  Md Mobashir Hasan Shandhi; Beren Semiz; Sinan Hersek; Nazli Goller; Farrokh Ayazi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-01-28       Impact factor: 5.772

7.  Universal Pre-Ejection Period Estimation Using Seismocardiography: Quantifying the Effects of Sensor Placement and Regression Algorithms.

Authors:  Hazar Ashouri; Sinan Hersek; Omer T Inan
Journal:  IEEE Sens J       Date:  2017-12-27       Impact factor: 3.301

8.  Estimation of Instantaneous Oxygen Uptake During Exercise and Daily Activities Using a Wearable Cardio-Electromechanical and Environmental Sensor.

Authors:  Md Mobashir Hasan Shandhi; William H Bartlett; James Alex Heller; Mozziyar Etemadi; Aaron Young; Thomas Plotz; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2021-03-05       Impact factor: 5.772

9.  On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

Authors:  Prasan Kumar Sahoo; Hiren Kumar Thakkar; Wen-Yen Lin; Po-Cheng Chang; Ming-Yih Lee
Journal:  Sensors (Basel)       Date:  2018-01-28       Impact factor: 3.576

10.  Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers.

Authors:  Loc Luu; Anh Dinh
Journal:  Sensors (Basel)       Date:  2018-04-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.