Optimization of a Moving Averages Program Using a Simulated Annealing Algorithm: The Goal is to Monitor the Process Not the Patients.

David Ng1, Frank A Polito1, Mark A Cervinski2.   

Abstract

BACKGROUND: The patient moving average (MA) is a QC strategy using the mean patient result to continuously monitor assay performance. Developing sensitive MA protocols that rapidly detect systematic error (SE) is challenging. We compare MA protocols established using a previously published report as a guide and demonstrate the use of a simulated annealing (SA) algorithm to optimize MA protocol performance.
METHODS: Using 400 days of patient data, we developed MA protocols for 23 assays. MA protocols developed using a previously published report and our SA algorithm were compared using the average number of patient samples affected until error detection (ANPed).
RESULTS: Comparison of the strategies demonstrated that protocols developed using the SA algorithm generally proved superior. Some analytes such as total protein showed considerable improvement, with positive SE equal to 0.8 g/dL detected with an ANPed of 135 samples using the previously published method whereas the SA algorithm detected this SE with an ANPed of 18. Not all analytes demonstrated similar improvement with the SA algorithm. Phosphorus, for instance, demonstrated only minor improvements, with a positive SE of 0.9 mg/dL detected with an ANPed of 34 using the previously published method vs an ANPed of 29 using the SA algorithm. We also demonstrate an example of SE detection in a live environment using the SA algorithm derived MA protocols.
CONCLUSIONS: The SA algorithm-developed MA protocols are currently in use in our laboratory and they rapidly detect SE, reducing the number of samples requiring correction and improving patient safety.
© 2016 American Association for Clinical Chemistry.

Entities:  

Mesh:

Year:  2016        PMID: 27540031     DOI: 10.1373/clinchem.2016.257055

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  9 in total

1.  A new method for detecting signal regions in ordered sequences of real numbers, and application to viral genomic data.

Authors:  Julia R Gog; Andrew M L Lever; Jordan P Skittrall
Journal:  PLoS One       Date:  2018-04-13       Impact factor: 3.240

2.  Moving Rate of Positive Patient Results as a Quality Control Tool for High-Sensitivity Cardiac Troponin T Assays.

Authors:  Tingting Li; Shunwang Cao; Yi Wang; Yujuan Xiong; Yuting He; Peifeng Ke; Xianzhang Huang
Journal:  Ann Lab Med       Date:  2020-08-25       Impact factor: 3.464

3.  Optimization and validation of patient-based real-time quality control procedure using moving average and average of normals with multi-rules for TT3, TT4, FT3, FT3, and TSH on three analyzers.

Authors:  Chao Song; Jun Zhou; Jun Xia; Deli Ye; Qian Chen; Weixing Li
Journal:  J Clin Lab Anal       Date:  2020-05-03       Impact factor: 2.352

4.  Intelligent Quality Management 2 with IntraSpect™ technology for quality control of GEM® Premier™ 5000 blood gas analyzers- A novel application of the patient sample as its own control.

Authors:  James O Westgard; Jose Cervera
Journal:  Pract Lab Med       Date:  2022-04-08

5.  A study of the moving rate of positive results for use in a patient-based real-time quality control program on a procalcitonin point-of-care testing analyzer.

Authors:  Yili He; Daqing Gu; Xiangzhi Kong; Zhiqiang Feng; Weishang Lin; Yunfeng Cai
Journal:  J Clin Lab Anal       Date:  2022-03-07       Impact factor: 2.352

6.  A study on quality control using delta data with machine learning technique.

Authors:  Yufang Liang; Zhe Wang; Dawei Huang; Wei Wang; Xiang Feng; Zewen Han; Biao Song; Qingtao Wang; Rui Zhou
Journal:  Heliyon       Date:  2022-07-14

7.  Assessment of patient based real-time quality control on comparative assays for common clinical analytes.

Authors:  Yide Lu; Fan Yang; Dongmei Wen; Kaifeng Shi; Zhichao Gu; Qiuya Lu; Xuefeng Wang; Danfeng Dong
Journal:  J Clin Lab Anal       Date:  2022-08-10       Impact factor: 3.124

8.  Optimizing moving average control procedures for small-volume laboratories: can it be done?

Authors:  Vera Lukić; Svetlana Ignjatović
Journal:  Biochem Med (Zagreb)       Date:  2019-10-15       Impact factor: 2.313

9.  Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium.

Authors:  Yuanyuan Li; Qian Yu; Xiaoyan Zhang; Xiaoling Chen
Journal:  J Clin Lab Anal       Date:  2021-09-14       Impact factor: 2.352

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.