Literature DB >> 27539271

Quantification of the accuracy limits of image registration using peak signal-to-noise ratio.

Yoshinori Tanabe1,2, Takayuki Ishida3.   

Abstract

A new method was developed for quantifying the accuracy limits of image registration devices and the distortion of anatomical structures in verification images without image registration. A correlation was found between peak signal-to-noise ratio (PSNR) and the amount of parallel movement (1-10 mm at 1-mm intervals) of a rectangular parallelepiped phantom [correlation coefficient (CC) -0.91, contribution ratio (CR) 0.83]. Rotating the phantom from 1° to 10° at 1° intervals produced a similar correlation with PSNR (CC -0.91, CR 0.83). To allow for manual registration, the grid pattern of the Mylar top plate was extracted from 455 pelvic portal images of 21 patients using a band-pass filtering technique. This revealed a different correlation between the original data (CC -0.62, CR 0.38) and averaged data (CC -0.96, CR 0.92), but this is considered to have been caused by structural distortion and manual matching errors. Thus, PSNR can be used to evaluate the accuracy limits of image registration and provide a judgment index that can be used in re-planning or re-setup in adaptive radiotherapy.

Entities:  

Keywords:  Adaptive radiotherapy; Geometric uncertainty; Image registration; Image-guided radiotherapy; Peak signal-to-noise ratio; Setup accuracy

Mesh:

Substances:

Year:  2016        PMID: 27539271     DOI: 10.1007/s12194-016-0372-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  8 in total

1.  Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179.

Authors:  Jean-Pierre Bissonnette; Peter A Balter; Lei Dong; Katja M Langen; D Michael Lovelock; Moyed Miften; Douglas J Moseley; Jean Pouliot; Jan-Jakob Sonke; Sua Yoo
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

Review 2.  A review of 3D/2D registration methods for image-guided interventions.

Authors:  P Markelj; D Tomaževič; B Likar; F Pernuš
Journal:  Med Image Anal       Date:  2010-04-13       Impact factor: 8.545

3.  Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy.

Authors:  Lifei Zhang; Adam S Garden; Justin Lo; K Kian Ang; Anesa Ahamad; William H Morrison; David I Rosenthal; Mark S Chambers; X Ronald Zhu; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-04-01       Impact factor: 7.038

Review 4.  Imaging and alignment for image-guided radiation therapy.

Authors:  James M Balter; Marc L Kessler
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

Review 5.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

6.  Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery.

Authors:  Jennifer De Los Santos; Richard Popple; Nzhde Agazaryan; John E Bayouth; Jean-Pierre Bissonnette; Mary Kara Bucci; Sonja Dieterich; Lei Dong; Kenneth M Forster; Daniel Indelicato; Katja Langen; Joerg Lehmann; Nina Mayr; Ishmael Parsai; William Salter; Michael Tomblyn; William T C Yuh; Indrin J Chetty
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-05-07       Impact factor: 7.038

7.  Evaluating positional accuracy using megavoltage cone-beam computed tomography for IMRT with head-and-neck cancer.

Authors:  Kana Motegi; Ryosuke Kohno; Takashi Ueda; Toshiyuki Shibuya; Takaki Ariji; Mitsuhiko Kawashima; Tetsuo Akimoto
Journal:  J Radiat Res       Date:  2014-01-20       Impact factor: 2.724

8.  Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy.

Authors:  Erminia Infusino; Lucio Trodella; Sara Ramella; Rolando M D'Angelillo; Carlo Greco; Aurelia Iurato; Luca E Trodella; Alessandro Nacca; Patrizia Cornacchione; Alessandra Mameli
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

  8 in total
  2 in total

1.  Impact of the suboptimal communication network environment on telerobotic surgery performance and surgeon fatigue.

Authors:  Harue Akasaka; Kenichi Hakamada; Hajime Morohashi; Takahiro Kanno; Kenji Kawashima; Yuma Ebihara; Eiji Oki; Satoshi Hirano; Masaki Mori
Journal:  PLoS One       Date:  2022-06-16       Impact factor: 3.752

2.  Sector sensor array technique for high conductivity materials imaging in magnetic induction tomography.

Authors:  Jia Chen; Li Ke; Qiang Du; Wanni Zu; Xiaodi Ding
Journal:  Biomed Eng Online       Date:  2019-12-02       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.