Literature DB >> 27520994

Solitaire stentectomy: 'deploy and engage' and 'loop and snare' techniques.

Rajsrinivas Parthasarathy1, Vipul Gupta1, Gaurav Goel2, Anshu Mahajan2.   

Abstract

Solitaire FR stent-based mechanical thrombectomy provides clinical benefit in selected patients with acute ischaemic stroke due to large vessel occlusion. A dreaded device complication that is associated with poor technical and clinical outcome is stent detachment. Retrieval of the detached stent can be technically challenging and has been attempted with variable success. The key benefit of this strategy is the lack of need to administer fibrinolytic/antiplatelet agents that can potentially be catastrophic in the setting of acute stroke. Therefore, retrieval may be preferred to other strategies (balloon angioplasty, lytic/glycoprotein 2b/3a inhibitors administration) to address detached stent. We report two patients in whom the detached stent was retrieved using alternative techniques-'deploy and engage' and 'loop and snare'-as snare retrieval failed. 2016 BMJ Publishing Group Ltd.

Entities:  

Keywords:  Device; Intervention; Stent; Stroke

Mesh:

Year:  2016        PMID: 27520994      PMCID: PMC4985994          DOI: 10.1136/bcr-2016-012547

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  8 in total

1.  Inadvertent Detachment of a Retrievable Intracranial Stent: Review of Manufacturer and User Facility Device Experience.

Authors:  Sang Yub Lee; Sung Won Youn; Ho Kyun Kim; Young Rok Do
Journal:  Neuroradiol J       Date:  2015-04-28

2.  Early detachment of the Solitaire stent during thrombectomy retrieval: an in vitro investigation.

Authors:  Hyon-Jo Kwon; Ju-Yu Chueh; Ajit S Puri; Hyeon-Song Koh
Journal:  J Neurointerv Surg       Date:  2014-01-16       Impact factor: 5.836

3.  Inadvertent Stent Retriever Detachment: A Multicenter Case Series and Review of Device Experience FDA Reports.

Authors:  Hesham Masoud; Thanh N Nguyen; Coleman O Martin; William E Holloway; Sudheer Ambekar; Dileep R Yavagal; Diogo C Haussen; Raul Nogueira; Diego J Lozano; Ajit Puri; Ayman Quateen; Daniela Iancu; Michael G Abraham; Michael Chen; Sonal Mehta; Tim Malisch; Franklin Marden; Robin Novakovic; Daniel Roy; Alain Weill; Alexander M Norbash
Journal:  Interv Neurol       Date:  2015-11-20

4.  Unexpected Detachment of Solitaire Stents during Mechanical Thrombectomy.

Authors:  Sung Tae Kim; Sung-Chul Jin; Hae Woong Jeong; Jung Hwa Seo; Sam Yeol Ha; Hae Wook Pyun
Journal:  J Korean Neurosurg Soc       Date:  2014-12-31

5.  Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial.

Authors:  Jeffrey L Saver; Reza Jahan; Elad I Levy; Tudor G Jovin; Blaise Baxter; Raul G Nogueira; Wayne Clark; Ronald Budzik; Osama O Zaidat
Journal:  Lancet       Date:  2012-08-26       Impact factor: 79.321

6.  Prospective, multicenter, single-arm study of mechanical thrombectomy using Solitaire Flow Restoration in acute ischemic stroke.

Authors:  Vitor M Pereira; Jan Gralla; Antoni Davalos; Alain Bonafé; Carlos Castaño; René Chapot; David S Liebeskind; Raul G Nogueira; Marcel Arnold; Roman Sztajzel; Thomas Liebig; Mayank Goyal; Michael Besselmann; Antonio Moreno; Alfredo Moreno; Gerhard Schroth
Journal:  Stroke       Date:  2013-08-01       Impact factor: 7.914

7.  Stent retrievers in acute ischemic stroke: complications and failures during the perioperative period.

Authors:  G Gascou; K Lobotesis; P Machi; I Maldonado; J F Vendrell; C Riquelme; O Eker; G Mercier; I Mourand; C Arquizan; A Bonafé; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-24       Impact factor: 3.825

8.  Unwanted detachment of the Solitaire device during mechanical thrombectomy in acute ischemic stroke.

Authors:  C Castaño; L Dorado; S Remollo; P García-Bermejo; M Gomis; N Pérez de la Ossa; M Millán; M R García-Sort; C Hidalgo; E López-Cancio; C Cubells; A Dávalos
Journal:  J Neurointerv Surg       Date:  2016-01-27       Impact factor: 5.836

  8 in total
  3 in total

1.  Endovascular stentectomy using the snare over stent-retriever (SOS) technique: An experimental feasibility study.

Authors:  Tareq Meyer; Omid Nikoubashman; Lisa Kabelitz; Marguerite Müller; Ahmed Othman; Saif Afat; Martin Kramer; Martin Wiesmann; Marc A Brockmann; Carolin Brockmann
Journal:  PLoS One       Date:  2017-05-25       Impact factor: 3.240

2.  Retained Solitaire FR device after mechanical thrombectomy: Case review and management strategies.

Authors:  Jay P Kinariwala; Gary B Rajah; Ali W Luqman
Journal:  Brain Circ       Date:  2018-12-31

3.  Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review.

Authors:  Sudheer Chakravarthi; Sai Kumar Reddy Pasya; Vamsi Krishna Gorijala; Anusha Guntamukkala; Kalyan Chakravarthy Sajja
Journal:  Cureus       Date:  2022-09-08