Literature DB >> 27520840

Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

Zhangxuan Hu1, Xiaodong Ma1, Trong-Kha Truong2, Allen W Song2, Hua Guo1.   

Abstract

PURPOSE: Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence and can be used with a high number of shots, but its convergence is slow, which limits its practical usage. The study here proposes an improved method based on both SENSE+CG and POCS-ICE, called Phase-updated Regularized SENSE (PR-SENSE), for navigator-free multishot diffusion imaging. THEORY AND METHODS: In PR-SENSE, a total variation regularization method is used to solve the SENSE inverse problem instead of the conjugate gradient method used in SENSE+CG. This method is implemented by using a lagged diffusivity fixed point iteration algorithm. Additionally, the phase is updated during the iteration process to improve the image accuracy.
RESULTS: Simulations and in vivo experiments demonstrated that PR-SENSE can successfully correct for the motion-induced phase errors in multi-shot DWI. It integrates the advantages of SENSE+CG and POCS-ICE, resulting in a fast and stable convergence with improved image quality.
CONCLUSION: Given its advantages, PR-SENSE is a significant improvement over other methods for navigator-free high-resolution DWI. Magn Reson Med 78:172-181, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  POCS-ICE; PR-SENSE; SENSE+CG; diffusion-weighted imaging (DWI); multishot diffusion imaging; phase correction

Mesh:

Year:  2016        PMID: 27520840     DOI: 10.1002/mrm.26361

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

2.  Motion-robust reconstruction of multishot diffusion-weighted images without phase estimation through locally low-rank regularization.

Authors:  Yuxin Hu; Evan G Levine; Qiyuan Tian; Catherine J Moran; Xiaole Wang; Valentina Taviani; Shreyas S Vasanawala; Jennifer A McNab; Bruce A Daniel; Brian L Hargreaves
Journal:  Magn Reson Med       Date:  2018-10-22       Impact factor: 4.668

3.  Distortion-free, high-isotropic-resolution diffusion MRI with gSlider BUDA-EPI and multicoil dynamic B0 shimming.

Authors:  Congyu Liao; Berkin Bilgic; Qiyuan Tian; Jason P Stockmann; Xiaozhi Cao; Qiuyun Fan; Siddharth Srinivasan Iyer; Fuyixue Wang; Chanon Ngamsombat; Wei-Ching Lo; Mary Kate Manhard; Susie Y Huang; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2021-03-10       Impact factor: 3.737

4.  A diffusion-matched principal component analysis (DM-PCA) based two-channel denoising procedure for high-resolution diffusion-weighted MRI.

Authors:  Nan-Kuei Chen; Hing-Chiu Chang; Ali Bilgin; Adam Bernstein; Theodore P Trouard
Journal:  PLoS One       Date:  2018-04-25       Impact factor: 3.752

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.