| Literature DB >> 27520833 |
Zhenpeng Peng1, Mengjie Jiang1,2, Huasong Cai1, Tao Chan3, Zhi Dong1, Yanji Luo1, Zi-Ping Li4, Shi-Ting Feng5.
Abstract
BACKGROUND: Variable degrees of differentiation in hepatocellular carcinoma(HCC)under Edmondson-Steiner grading system has been proven to be an independent prognostic indicator for HCC. Up till now, there has been no effective radiological method that can reveal the degree of differentiation in HCC before surgery. This paper aims to evaluate the use of Gd-EOB-DTPA-Enhanced Magnetic Resonance Imaging combined with T1 mapping for the diagnosis of HCC and assessing its degree of differentiation.Entities:
Keywords: Differentiated degrees; Edmondson-Steiner grade; Gd-EOB-DTPA; Hepatocellular Carcinoma; T1 mapping
Mesh:
Substances:
Year: 2016 PMID: 27520833 PMCID: PMC4983030 DOI: 10.1186/s12885-016-2607-4
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Edmondson-Steiner grade
| Edmondson-Steiner grade | |
|---|---|
| I | Cells with abundant cytoplasm and minimal nuclear irregularity |
| II | Greater nuclear irregularity and prominent nucleoli |
| III | Increased nuclear pleomorphism and angulation of the nuclei; Tumour giant cells were also more commonly seen |
| IVa | Poorly differentiated with marked nuclear pleomorphism, hyperchromatism and anaplasia |
aLimited by study population, this study did not include HCC of Edmondson-Steiner grade IV
MRI sequences used in the study
| Sequence | TR(ms) | TE(ms) | FA | Scan time (s) | Slice thickness (mm) | Matrix | FOV |
|---|---|---|---|---|---|---|---|
| Plain scan | |||||||
| T1WI | 225 | 2.2 | 70 | 19.42 | 6 | 200 × 320 | 258 × 330 |
| T2WI | 2000 | 91 | 150 | 106 | 6 | 410 × 512 | 350 × 350 |
| VIBE-T1mapping | 4.4 | 1.2 | 2,12 | 20.15 | 2 | 154 × 256 | 248 × 330 |
| DCE | |||||||
| VIBE | 3.3 | 1.2 | 13 | 8.21/phase | 2 | 96 × 256 | 248 × 330 |
| Hepatobiliary-phase | |||||||
| T1WI | 225 | 2.2 | 70 | 19.42 | 6 | 200 × 320 | 258 × 330 |
| VIBE-T1mapping | 4.4 | 1.2 | 2,12 | 20.15 | 2 | 154 × 256 | 248 × 330 |
Fig. 1a, b T1 values in T1 mapping images was measured before (T1p) and after (T1e) administration of the contrast medium. The two ROIs were chosen at the same place in the same lesions
Size of lesions for different Edmondson-Steiner grade
| Edmondson-Steiner grade | No. | Diameters (mean, mm)a |
|---|---|---|
| I | 13 | 31.3 ± 23.7 |
| II | 27 | 25.4 ± 23.5 |
| III | 13 | 38.8 ± 35.6 |
| Total | 53 | 30.1 ± 28.5 |
aThere was no statistically significant difference between three groups (P = 0.389)
Fig. 2Row a: T1 weightedimages, Row b: T2 weightedI image, Row c: arterial phase image, Row d: potal venous phase image, Row e: hepatobiliary phase images; Row f: and Row g: T1 mapping of T1WI and hepatobiliary phase images; row h: corresponding pathological pictures. 1a-h, HCC (Edmondson-Steiner grade I). Lesion appeared hyperintense on routine sequences and hypointense in hepatobiliary-phase; T1p 892ms, T1e 388 ms, T1d = 504 ms, T1d % = 56.50 %; cells showed abundant cytoplasm and minimal nuclear irregularity. 2a-h, HCC (Edmondson-Steiner grade II), hypointense on T1WI and hepatobiliary phase images, “wash in and wash out”; T1p 1696 ms, T1e 1444 ms, T1d = 252 ms, T1d % = 14.90 %. 3a-h, HCC (Edmondson-Steiner grade III), hyperintense on T2WI images, hypointense on T1WI and hepatobiliary phase images; T1p 2134 ms, T1e 1494 ms,T1d = 640 ms,T1d % = 30.00 %. 2-h and 3-h, nuclear pleomorphism increased with increase in Edmondson-Steiner grade
Fig. 3Values of T1p, T1e, T1d, T1d % in different groups and all of the studied lesions
Fig. 4The average value of T1d and T1d % in HCC of different Edmondson-Steiner grades. Box-and-whisker plots showed that there was statistical significance of T1d and T1d % between grade I and the other two groups, but no statistically significant difference between grade II and grade III lesions
Correlation analysis between T1p, T1e, T1d, T1d % and Edmondson-Steiner grade
| T1p | T1e | T1d | T1d % | |
|---|---|---|---|---|
| Correlation index | −0.065 | 0.335 | −0.570 | −0.676a |
| P | 0.643 | 0.014 | 0.000 | 0.000 |
| N | 53 | 53 | 53 | 53 |
aT1d % had the best correlation with Edmondson-Steiner grade with a correlation index 0.676