Literature DB >> 27502223

Comparison of modern locked plating and antiglide plating for fixation of osteoporotic distal fibular fractures.

Paul J Switaj1, Robert J Wetzel2, Neel P Jain3, Brian M Weatherford4, Yupeng Ren5, Li-Qun Zhang5, Bradley R Merk2.   

Abstract

BACKGROUND: Fractures in osteoporotic patients can be difficult to treat because of poor bone quality and inability to gain screw purchase. The purpose of this study is to compare modern lateral periarticular distal fibula locked plating to antiglide plating in the setting of an osteoporotic, unstable distal fibula fracture.
METHODS: AO/OTA 44-B2 distal fibula fractures were created in sixteen paired fresh frozen cadaveric ankles and fixed with a lateral locking plate and an independent lag screw or an antiglide plate with a lag screw through the plate. The specimens underwent stiffness, cyclic loading, and load to failure testing. The energy absorbed until failure, torque to failure, construct stiffness, angle at failure, and energy at failure was recorded.
RESULTS: The lateral locking construct had a higher torque to failure (p=0.02) and construct stiffness (p=0.04). The locking construct showed a trend toward increased angle at failure, but did not reach statistical significance (p=0.07). Seven of the eight lateral locking plate specimens failed through the distal locking screws, while the antiglide plating construct failed with pullout of the distal screws and displacement of the fracture in six of the eight specimens.
CONCLUSION: In our study, the newly designed distal fibula periarticular locking plate with increased distal fixation is biomechanically stronger than a non-locking one third tubular plate applied in antiglide fashion for the treatment of AO/OTA 44-B2 osteoporotic distal fibula fractures. LEVEL OF EVIDENCE: V: This is an ex-vivo study performed on cadavers and is not a study performed on live patients. Therefore, this is considered Level V evidence.
Copyright © 2015. Published by Elsevier Ltd.

Entities:  

Keywords:  Antiglide; Fibula; Fixation; Locked plating; Osteoporosis

Mesh:

Year:  2015        PMID: 27502223     DOI: 10.1016/j.fas.2015.06.007

Source DB:  PubMed          Journal:  Foot Ankle Surg        ISSN: 1268-7731            Impact factor:   2.705


  4 in total

Review 1.  [Osteoporotic bone fractures: intramedullary augmentation and hybrid osteosynthesis].

Authors:  Thomas Gausepohl; Sascha Gick; Steffen Heck; Dietmar Pennig
Journal:  Unfallchirurg       Date:  2019-08       Impact factor: 1.000

2.  A short single-incision approach for antiglide plate fixation of oblique fractures of the lateral malleolus: a technical tip.

Authors:  Rogério Carneiro Bitar; Danilo Ryuko Cândido Nishikawa; Cesar de Cesar Netto; Alexandre Leme Godoy-Santos; Robinson Esteves Santos Pires
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-08-17

Review 3.  Osteoporotic ankle fractures: A narrative review of management options.

Authors:  Mandeep S Dhillon; Rajesh Kumar Rajnish; Sandeep Patel; Devendra K Chouhan; Tungish Bansal
Journal:  J Clin Orthop Trauma       Date:  2019-11-04

4.  Is early full weight bearing safe following locking plate ORIF of distal fibula fractures?

Authors:  Michael Zyskowski; Markus Wurm; Frederik Greve; Sebastian Pesch; Francesca von Matthey; Patrick Pflüger; Moritz Crönlein; Peter Biberthaler; Chlodwig Kirchhoff
Journal:  BMC Musculoskelet Disord       Date:  2021-02-09       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.