| Literature DB >> 27494933 |
Mi-Jung Yun1, Jung-Won Hwang2, Sung-Hoon Kim1, Hyo-Ju Hong1, Young-Tae Jeon3, Hee-Pyoung Park4.
Abstract
BACKGROUND: The sniffing position (neck flexion by head elevation and head extension) is commonly used for insertion of a laryngeal mask airway. However, the appropriate degrees of head elevation and head extension are unclear. In the present study, the success rate of ProSeal™ laryngeal mask airway (LMA ProSeal) insertion using two degrees of head elevation was evaluated.Entities:
Keywords: Airway; Head position; LMA; PLMA
Mesh:
Year: 2016 PMID: 27494933 PMCID: PMC4974810 DOI: 10.1186/s12871-016-0220-3
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Fig. 1Flow diagram generated in accordance with CONSORT 2010 guidelines
Patients’ characteristics
| Group 3 cm ( | Group 6 cm ( | |
|---|---|---|
| Age (years) | 59 ± 13 (29–82) | 57 ± 13 (20–77) |
| M/F | 20/18 | 22/18 |
| Weight (kg) | 63 ± 9 (49–83) | 65 ± 12 (42–87) |
| Height (cm) | 162 ± 7 (148–176) | 163 ± 8 (149–181) |
| Mallampati class (1/2/3) | 31/5/2 | 33/5/2 |
| Anesthesia time (min) | 73 ± 35 (30–215) | 77 ± 33 (35–230) |
Data are presented as means ± standard deviation (range) or numbers of patients. Group 3 cm, used a 3 cm height pillow. Group 6 cm, used a 6 cm height pillow
Results of ProSeal laryngeal mask airway insertion
| Group 3 cm ( | Group 6 cm ( |
| |
|---|---|---|---|
| No. of attempts | |||
| 1 | 33/38 (86) | 24/40 (60) | 0.014 |
| 2 | 1/38(3) | 9/40 (23) | |
| Failure | 4/38 (11) | 7 (18) | |
| 3 | 2/4 (50) | 6/7 (86) | |
| Repositioning | 3 (7) | 4 (10) | 0.745 |
| Seal pressure (cmH2O) | 26 ± 5 (15–38) | 26 ± 5 (14–32) | 0.799 |
| Size of PLMA (4/5) | 19/19 | 20/20 | 1.000 |
Data are numbers (%), means ± standard deviation (range) or numbers of patients. Group 3 cm, used a 3 cm height pillow. Group 6 cm, used a 6 cm height pillow. PLMA, ProSeal laryngeal mask airway
Airway axis and alignment
| Group 3 cm ( | Group 6 cm ( |
| |
|---|---|---|---|
| Angle of ventral neck (°) | 26.1 ± 7.6 | 33.7 ± 8.8 | <0.01 |
| Oral axis | 90.3 ± 8.5 | 101.9 ± 9.6 | <0.01 |
| Oral axis - angle of ventral neck | 64.1 ± 11.9 | 68.2 ± 13.0 | 0.123 |
Data are means ± standard deviation. Group 3 cm, used a 3 cm height pillow. Group 6 cm, used a 6 cm height pillow. Angle of ventral neck, an imaginary line along the long axis of the trachea; oral axis, an imaginary midline perpendicular to the line between the upper and lower lip
Hemodynamic variables and complications
| Group 3 cm ( | Group 6 cm ( |
| |
|---|---|---|---|
| Mean blood pressure (mmHg) | |||
| Preinsertion | 65 ± 10 | 64 ± 13 | 0.707 |
| Postinsertion | 69 ± 14 | 69 ± 15 | 0.987 |
| Heart rate (bpm) | |||
| Preinsertion | 68 ± 14 | 67 ± 15 | 0.731 |
| Postinsertion | 69 ± 14 | 70 ± 14 | 0.830 |
| Blood staining on PLMA | 5 (13) | 6 (15) | 1.000 |
| Sore throat after recovery | 10 (26) | 14 (35) | 0.467 |
| Hoarseness after recovery | 4 (10) | 4 (10) | 1.000 |
Data are means ± standard deviation or numbers of patients (%). Group 3 cm, used a 3 cm height pillow. Group 6 cm, used a 6 cm height pillow. PLMA, ProSeal laryngeal mask airway