Literature DB >> 2748815

Incorporation versus infection of retroperitoneal aortic grafts: MR imaging features.

W Auffermann1, P A Olofsson, G N Rabahie, N J Tavares, R J Stoney, C B Higgins.   

Abstract

The magnetic resonance (MR) imaging characteristics of normal aortic graft healing were compared with those of perigraft infection in 57 patients after aortic graft implantation. Thirty-three patients without postoperative complications underwent MR imaging in a 0.35-T unit 1 week after graft implantation, and 13 of those patients were reexamined 2-3 months after graft implantation. Twenty-four patients with clinically suspected perigraft infection underwent MR imaging 6 weeks to 18 years after graft implantation. Early normal postoperative changes were characterized by a perigraft collar of low to medium signal intensity on T1-weighted images and of high intensity on T2-weighted images in all 33 cases, consistent with perigraft fluid collection. In 10 of 13 patients reexamined 2-3 months postoperatively, the MR images demonstrated a collar of tissue consistent with perigraft fibrosis. In cases of clinical suspicion of retroperitoneal graft infection, MR imaging showed eccentric fluid collections of low to medium signal intensity on T1-weighted images and high intensity on T2-weighted images at more than 3 months after surgery. The MR findings were diagnostic of retroperitoneal perigraft infection in 17 of 20 patients shown to be infected at surgery. Retroperitoneal infection was correctly excluded on the basis of MR findings in four patients. Thus, MR imaging is an accurate imaging method for the diagnosis of aortic graft infection. In the early postoperative phase, resolving perigraft fluid cannot be differentiated from perigraft infection.

Entities:  

Mesh:

Year:  1989        PMID: 2748815     DOI: 10.1148/radiology.172.2.2748815

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Aortoenteric fistula.

Authors:  S Thomson
Journal:  J R Soc Med       Date:  1999-08       Impact factor: 5.344

2.  STIR imaging of synthetic vascular graft infection.

Authors:  M E Hansen; E K Yucel; A C Waltman
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Jan-Feb       Impact factor: 2.740

Review 3.  Imaging Modalities for the Diagnosis of Vascular Graft Infections: A Consensus Paper amongst Different Specialists.

Authors:  Chiara Lauri; Roberto Iezz; Michele Rossi; Giovanni Tinelli; Simona Sica; Alberto Signore; Alessandro Posa; Alessandro Tanzilli; Chiara Panzera; Maurizio Taurino; Paola Anna Erba; Yamume Tshomba
Journal:  J Clin Med       Date:  2020-05-17       Impact factor: 4.241

  3 in total