| Literature DB >> 27484188 |
Xin Ye1,2, Jin Huang1,3, Hongjie Liu1, Feng Geng1, Laixi Sun1, Xiaodong Jiang1, Weidong Wu1, Liang Qiao2, Xiaotao Zu4, Wanguo Zheng1,5.
Abstract
The laser damage precursors in subsurface of fused silica (e.g. photosensitive impurities, scratches and redeposited silica compounds) were mitigated by mineral acid leaching and HF etching with multi-frequency ultrasonic agitation, respectively. The comparison of scratches morphology after static etching and high-frequency ultrasonic agitation etching was devoted in our case. And comparison of laser induce damage resistance of scratched and non-scratched fused silica surfaces after HF etching with high-frequency ultrasonic agitation were also investigated in this study. The global laser induce damage resistance was increased significantly after the laser damage precursors were mitigated in this case. The redeposition of reaction produce was avoided by involving multi-frequency ultrasonic and chemical leaching process. These methods made the increase of laser damage threshold more stable. In addition, there is no scratch related damage initiations found on the samples which were treated by Advanced Mitigation Process.Entities:
Year: 2016 PMID: 27484188 PMCID: PMC4971457 DOI: 10.1038/srep31111
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Schematic illustration of known precursors on fused silica surfaces and subsurface.
The precursors are impurities in the Beilby polishing layer or cracks, the intrinsic silica defects on fracture surfaces (i.e., cracks) and redeposit of silica.
Figure 2Depth profiles of impuritie elements detected in fused silica surface by TOF-SMIS: (A) Without leaching; (B) Leaching; (C) thermal absorption of fused silica with and without leaching.
Figure 3Damage probability (A) and Damage density (B) of fused silica with and without leaching. the morphology of damage site on surface of fused silica with and without leaching.
Figure 4Optical micrographs of cracks generated on fused silica after HF etching with the addition of agitation (A, 5 min etching; B, 50 min etching, and C, 100 min etching) and static HF etching (D, 5 min etching; B, 50 min etching, and C, 100 min etching). The scale bar is 100 μm.
Figure 5Damage probability (A) and Damage density (B) of fused silica etched different times.
Figure 6The morphology of damage site of different samples: (A) without process, (B) leaching and HF etching 5 min, (C) leaching and HF etching 50 min, (D) leaching and HF etching 100 min. The scale bar is 100 μm.