Literature DB >> 27474323

Portable and low cost fluorescence set-up for in-situ screening of Ochratoxin A.

Diana Bueno1, Rupesh K Mishra2, Akhtar Hayat3, Gaëlle Catanante4, Vinay Sharma5, Roberto Muñoz6, Jean-Louis Marty7.   

Abstract

The present article describes a portable and low cost fluorescence set-up designed and characterized for in-situ screening of Ochratoxin A (OTA) in cocoa samples at field settings. The sensing module (the set up) consists of a LED with the wavelength of 370-380nm and a color complementary metal oxide semiconductor (CMOS) micro-camera inbuilt at upright position of a black box to obtain an image of the sensing molecule. It allows the user to get an image of the sensing analytes under excitation conditions and process the image in order to predict the toxicity of the samples. The image capturing and processing of the system was based on the OTA concentration in the sample and analyzed data can be presented as RGB values. For each concentration of the OTA, the R, G, B co-ordinates were obtained and plotted to quantify actual OTA presents in the sample. Moreover, the system was tested for real sample analysis using cocoa contaminated with OTA. The system could detect OTA as low as 1.25ng/ml with the maximum recovery of 87.5% in cocoa samples. The OTA was extracted in 1% NaHCO3 and cleaned up using molecular imprinted polymer column (MIP). The method demonstrated a good linear range between 1.25 and 10ng/ml. The obtained results were cross validated using chromatographic method HPLC and also compared with commercially available fluorescence instrument. The developed fluorescence setup is simple, economical, and portable with added advantages of digital image processing. The system could be deployable to cocoa fields for monitoring of OTA in quick successions. It is noteworthy to mention that this is the first report of such portable fluorescence setup where, OTA sensing was explored.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cocoa; Extraction; Fluorescence set up; MIP; OTA

Mesh:

Substances:

Year:  2016        PMID: 27474323     DOI: 10.1016/j.talanta.2016.06.039

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Colorimetric Analysis of Ochratoxin A in Beverage Samples.

Authors:  Diana Bueno; Luis F Valdez; Juan Manuel Gutiérrez Salgado; Jean Louis Marty; Roberto Muñoz
Journal:  Sensors (Basel)       Date:  2016-11-10       Impact factor: 3.576

2.  Highly sensitive label-free in vitro detection of aflatoxin B1 in an aptamer assay using optical planar waveguide operating as a polarization interferometer.

Authors:  Ali Al-Jawdah; Alexei Nabok; Hisham Abu-Ali; Gaelle Catanante; Jean-Louis Marty; Andras Szekacs
Journal:  Anal Bioanal Chem       Date:  2019-08-07       Impact factor: 4.142

3.  Development of a Magnetic Nanoparticles-Based Screen-Printed Electrodes (MNPs-SPEs) Biosensor for the Quantification of Ochratoxin A in Cereal and Feed Samples.

Authors:  Xian Zhang; Zuohuan Wang; Hui Xie; Renjie Sun; Tong Cao; Narayan Paudyal; Weihuan Fang; Houhui Song
Journal:  Toxins (Basel)       Date:  2018-08-06       Impact factor: 4.546

4.  A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples.

Authors:  Guilan Zhang; Chao Zhu; Yafei Huang; Jiao Yan; Ailiang Chen
Journal:  Molecules       Date:  2018-01-31       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.