Literature DB >> 27450707

Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

Debabrata Basu1.   

Abstract

Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc.
Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Conclusion; Consequences of wet pack; Cost complications; Prevention; Root cause of wet pack

Mesh:

Substances:

Year:  2016        PMID: 27450707     DOI: 10.1016/j.jiph.2016.06.009

Source DB:  PubMed          Journal:  J Infect Public Health        ISSN: 1876-0341            Impact factor:   3.718


  3 in total

1.  Application of a sub-specialties management model improves quality control in a central sterile supply department.

Authors:  Li Wang; Xuejiao Cai; Ping Cheng
Journal:  BMC Health Serv Res       Date:  2018-05-30       Impact factor: 2.655

2.  Analysis of water quality over non-condensable gases concentration on steam used for sterilization.

Authors:  Emerson Aparecido Miguel; Paulo Roberto Laranjeira; Marina Ishii; Terezinha de Jesus Andreoli Pinto
Journal:  PLoS One       Date:  2022-09-27       Impact factor: 3.752

3.  Compliance of primary and secondary care public hospitals with standard practices for reprocessing and steam sterilization of reusable medical devices in Nepal: findings from nation-wide multicenter clustered audits.

Authors:  Gopal Panta; Ann K Richardson; Ian C Shaw; Patricia A Coope
Journal:  BMC Health Serv Res       Date:  2020-10-07       Impact factor: 2.655

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.