Literature DB >> 27448546

A sensitive and real-time assay of trypsin by using molecular imprinting-based capacitive biosensor.

Gizem Ertürk1, Martin Hedström1, Bo Mattiasson1.   

Abstract

Use of a highly sensitive, selective capacitive biosensor is reported for label-free, real-time, easy and rapid detection of trypsin by using the microcontact imprinting method. Real-time trypsin detection was performed with trypsin-imprinted (trypsin-MIP) capacitive electrodes using standard trypsin solutions in the concentration range of 1.0×10(-13)-1.0×10(-7)M with a detection limit of 3.0×10(-13)M. Selectivity and cross-reactivity of the system were tested by using competing proteins including chymotrypsin (chy), bovine serum albumin (BSA), lysozyme (lyz) and cytochrome c (cyt c) in singular and competitive manner and the selectivity of the system was determined with the selectivity coefficients of approximately 705.1, 6.5, 6.4 and 5.1 for chy, BSA, lyz and cyt c, respectively. The trypsin-MIP capacitive electrode was used for ~80 assays during 2 months and retained its binding property during all that time with a decrease of approximately 2.3% in the signal amplitude. In the last step, trypsin activity was measured by using Nα-Benzoyl-D, l-arginine 4-nitroanilide hydrochloride (BAPNA) as the substrate with spectrophotometer at 410nm. The trypsin activity was measured as 9mU/mL by spectrophotometer while the amount of captured enzyme calculated from the capacitive system was 7.9mU/mL which shows the correlation between two methods. From the comparison it is obvious that the new method is an attractive alternative for assaying trypsin and the developed capacitive system might be used successfully to monitor label-free, real-time enzymatic activity of different proteases in a sensitive, rapid, cost-effective manner for different applications.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capacitive biosensor; Cross-reactivity; Microcontact imprinting; Selectivity

Mesh:

Substances:

Year:  2016        PMID: 27448546     DOI: 10.1016/j.bios.2016.07.046

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

Review 1.  Molecularly Imprinted Polymer-Based Sensors for SARS-CoV-2: Where Are We Now?

Authors:  Aysu Yarman; Sevinc Kurbanoglu
Journal:  Biomimetics (Basel)       Date:  2022-05-06

Review 2.  Capacitive Biosensors and Molecularly Imprinted Electrodes.

Authors:  Gizem Ertürk; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-02-17       Impact factor: 3.576

3.  Highly sensitive detection and quantification of the secreted bacterial benevolence factor RoxP using a capacitive biosensor: A possible early detection system for oxidative skin diseases.

Authors:  Gizem Ertürk; Martin Hedström; Bo Mattiasson; Tautgirdas Ruzgas; Rolf Lood
Journal:  PLoS One       Date:  2018-03-01       Impact factor: 3.240

4.  Capacitive Sensor to Monitor Enzyme Activity by Following Degradation of Macromolecules in Real Time.

Authors:  Gizem Ertürk Bergdahl; Martin Hedström; Bo Mattiasson
Journal:  Appl Biochem Biotechnol       Date:  2019-04-24       Impact factor: 2.926

Review 5.  Recent Advances in MXene Nanocomposite-Based Biosensors.

Authors:  Jinho Yoon; Minkyu Shin; Joungpyo Lim; Ji-Young Lee; Jeong-Woo Choi
Journal:  Biosensors (Basel)       Date:  2020-11-20

Review 6.  Realization of user-friendly bioanalytical tools to quantify and monitor critical components in bio-industrial processes through conceptual design.

Authors:  Carl-Fredrik Mandenius
Journal:  Eng Life Sci       Date:  2021-11-29       Impact factor: 2.678

7.  Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor.

Authors:  Gizem Ertürk; Rolf Lood
Journal:  J Vis Exp       Date:  2018-02-16       Impact factor: 1.355

Review 8.  How Reliable Is the Electrochemical Readout of MIP Sensors?

Authors:  Aysu Yarman; Frieder W Scheller
Journal:  Sensors (Basel)       Date:  2020-05-08       Impact factor: 3.576

9.  Capacitive Saccharide Sensor Based on Immobilized Phenylboronic Acid with Diol Specificity.

Authors:  Gizem Ertürk Bergdahl; Martin Hedström; Bo Mattiasson
Journal:  Appl Biochem Biotechnol       Date:  2018-10-28       Impact factor: 2.926

10.  The Effect of the Synthesis Method on Physicochemical Properties of Selective Granular Polymer Sorbents.

Authors:  Alexandra Osipenko; Irina Garkushina
Journal:  Polymers (Basel)       Date:  2022-01-17       Impact factor: 4.329

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.