Literature DB >> 27437315

Functional and Radiological Outcome of Schatzker type V and VI Tibial Plateau Fracture Treatment with Dual Plates with Minimum 3 years follow-up: A Prospective Study.

Neil Rohra1, Harpreet Singh Suri2, Kewal Gangrade3.   

Abstract

INTRODUCTION: High energy intra-articular fractures involving the tibial plateau causes various problems related to management like wound dehiscence, severe comminution leading to malalignment and delayed complications like varus collapse, implant failure and arthritis of knee joint. AIM: This study was done to determine functional, radiological outcome and the complications of Schatzker V and VI tibial plateau fractures treated with bipillar plating with dual plates with a regular follow-up of atleast 3 years.
MATERIALS AND METHODS: Total 34 cases of tibial plateau fracture type V and VI treated with dual plating were studied from January 2011 to December 2013 in KIMS Hospital were followed for minimum of 3 years. The patients were operated through an anterolateral approach for lateral plate and a medial column plate was put through a minimally invasive medial approach or an open posteromedial approach.
RESULTS: Total 34 patients were evaluated postoperatively thoroughly for functional outcome using The Knee Society Score and radiological outcomes by Modified Rasmussen Assessment criteria which showed 29 patients (85.29%) had excellent and 5 patients (14.71%) had good objective knee society score. 24 patients (70.59%) had excellent, 8 patients (23.53%) had good and 1patient (2.94%) were each of poor and fair functional knee society score. Eleven patients (32.35%) had excellent, 21patients (61.76%) had good and 2 patients (5.88%) had fair radiological outcome.
CONCLUSION: We conclude that open reduction and internal fixation of high-energy tibial plateau fractures with dual plates via 2 incisions gives excellent to good functional outcome with minimal soft tissue complications. Thus, a minimally invasive approach should be used which helps in preventing soft tissue problems and helps in early wound healing. Fixation done by bipillar plating is important for early mobilization of knee joint. Early mobilization leads to better range of movements and thereby better functional outcome.

Entities:  

Keywords:  Dual plating; Knee society score; Proximal tibia; Rasmussen assessment criteria

Year:  2016        PMID: 27437315      PMCID: PMC4948491          DOI: 10.7860/JCDR/2016/18732.7855

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  26 in total

1.  Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator. Biomechanical study and operative technique.

Authors:  A M Ali; L Yang; M Hashmi; M Saleh
Journal:  Injury       Date:  2001-12       Impact factor: 2.586

2.  Treatment of complicated tibial plateau fractures with dual plating via a 2-incision technique.

Authors:  Yong Zhang; De-gang Fan; Bao-an Ma; Si-guo Sun
Journal:  Orthopedics       Date:  2012-03-07       Impact factor: 1.390

3.  Tibial condylar fractures. Impairment of knee joint stability as an indication for surgical treatment.

Authors:  P S Rasmussen
Journal:  J Bone Joint Surg Am       Date:  1973-10       Impact factor: 5.284

4.  Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique.

Authors:  David P Barei; Sean E Nork; William J Mills; M Bradford Henley; Stephen K Benirschke
Journal:  J Orthop Trauma       Date:  2004 Nov-Dec       Impact factor: 2.512

Review 5.  Arthroscopy assisted operative management of tibial plateau fractures.

Authors:  G M Buchko; D H Johnson
Journal:  Clin Orthop Relat Res       Date:  1996-11       Impact factor: 4.176

Review 6.  High-energy fractures of the tibial plateau.

Authors:  J T Watson
Journal:  Orthop Clin North Am       Date:  1994-10       Impact factor: 2.472

Review 7.  [Pearls and pitfalls for the treatment of tibial head fractures].

Authors:  T M Kraus; T Freude; U Stöckle; F M Stuby
Journal:  Orthopade       Date:  2016-01       Impact factor: 1.087

Review 8.  Tibial plateau fractures. Management and expected results.

Authors:  H Tscherne; P Lobenhoffer
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

9.  Degenerative arthritis after tibial plateau fractures.

Authors:  S E Honkonen
Journal:  J Orthop Trauma       Date:  1995       Impact factor: 2.512

10.  Surgical approach for high-energy posterior tibial plateau fractures.

Authors:  Shu-Qing Wang; You-Shui Gao; Jia-Qi Wang; Chang-Qing Zhang; Jiong Mei; Zhi-Tao Rao
Journal:  Indian J Orthop       Date:  2011-03       Impact factor: 1.251

View more
  7 in total

1.  A clinico-radiological study of bicondylar tibial plateau fractures managed with dual locking plates.

Authors:  Virender Kumar; Mamta Singhroha; Kunal Arora; Ankur Sahu; Rajpal Beniwal; Ankush Kundu
Journal:  J Clin Orthop Trauma       Date:  2021-08-12

2.  Comparative Study of Function and Quality of Life in Patients with Fracture of the Tibial Plateau Operated with Locked or Conventional Plates.

Authors:  Bruno Gonçalves Schröder E Souza; Thiago Avelino Leite; Tarsis Aparecido Bueno da Silva; Carlos Otavio Fabiano de Faria Candido; Felipe Freesz de Almeida; Valdeci Manoel de Oliveira
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-03-01

3.  Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation.

Authors:  Koushik Narayan Subramanyam; Madhusudhan Tammanaiah; Abhishek Vasant Mundargi; Ritesh Nilakanthrao Bhoskar; Patllola Siddharth Reddy
Journal:  Chin J Traumatol       Date:  2019-04-13

4.  Fixation of Posterior Tibial Plateau Fracture with Additional Posterior Plating Improves Early Rehabilitation and Patient Satisfaction.

Authors:  Shivam Sinha; Mahipat Singh; Shyam K Saraf; Amit Rastogi; Alok K Rai; Tej Bali Singh
Journal:  Indian J Orthop       Date:  2019 May-Jun       Impact factor: 1.251

5.  Mid-Term Radiological and Functional Outcomes of Bicondylar Tibial Plateau Fractures Managed with Open Reduction and Internal Fixation Using Dual Plates.

Authors:  Angelo V Vasiliadis; Frideriki Poutoglidou; Dimitrios Metaxiotis; Anastasios Mpeletsiotis
Journal:  Sultan Qaboos Univ Med J       Date:  2022-02-28

6.  Ilizarov Ring External Fixation for Complex Tibial Plateau Fractures.

Authors:  Anil Ghimire; Pramod Devkota; Kailash Kumar Bhandari; Yubaraj Kharel; Saju Pradhan
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2021-11-11

7.  A case report of Schatzker type VI tibial plateau fracture treated with double reverse traction closed reduction combined with minimally invasive percutaneous plate osteosynthesis technique: A case report.

Authors:  Dian-Qing Li; De-Ye Song; Jiang-Dong Ni; Mu-Liang Ding; Jun Huang
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.