INTRODUCTION: Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. AIM: To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals.
MATERIALS AND METHODS: In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer's I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6'0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm(2)) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software.
RESULTS: There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer's (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer's test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus height on slit lamp and Optical coherence based tear meniscus area were similar in both sexes (p=0.5 and p=0.1). However, tear meniscus height on optical coherence tomography was significantly higher in females (p=0.04). Value of Schirmer's and tear film break up time (r =0.2; p= 0.001) and Schirmer's and tear meniscus height on slit lamp (r=0.6; p<0.001) had positive correlation. Tear meniscus height and tear meniscus area on optical coherence tomography had positive correlation (r =.9; p<0.001).
CONCLUSION: On optical coherence tomography tear meniscus height and area significantly correlated. Despite higher values of Schirmer's, tear film break up time, Slit lamp based tear meniscus height in younger age group the tear meniscus height and tear meniscus area with optical coherence tomography were lower.

Entities:  

Keywords:  Tear film break up time; Tear meniscus area; Tear meniscus height

Year:  2016        PMID: 27437253      PMCID: PMC4948429          DOI: 10.7860/JCDR/2016/18717.7722

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  23 in total

1.  Tear film profile in dry eye.

Authors:  A K Khurana; R Chaudhary; B K Ahluwalia; S Gupta
Journal:  Acta Ophthalmol (Copenh)       Date:  1991-02

Review 2.  A clinician looks at the tearfilm.

Authors:  J D Nelson
Journal:  Adv Exp Med Biol       Date:  1998       Impact factor: 2.622

3.  Tear meniscus height, lower punctum lacrimale, and the tear lipid layer in normal aging.

Authors:  Sudi Patel; Iain Wallace
Journal:  Optom Vis Sci       Date:  2006-10       Impact factor: 1.973

4.  Physical chemistry of the normal and disordered tear film.

Authors:  F J Holly
Journal:  Trans Ophthalmol Soc U K       Date:  1985

5.  Video-assessment of tear meniscus height in elderly Caucasians and its relationship to the exposed ocular surface.

Authors:  M J Doughty; M Laiquzzaman; N F Button
Journal:  Curr Eye Res       Date:  2001-06       Impact factor: 2.424

6.  Tear meniscus evaluation by optical coherence tomography.

Authors:  Giacomo Savini; Piero Barboni; Maurizio Zanini
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2006 Mar-Apr

7.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study.

Authors:  Sheng Zhou; Yan Li; Ake Tzu-Hui Lu; Pengfei Liu; Maolong Tang; Samuel C Yiu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct

8.  Optical coherence tomography for measuring the tear film meniscus: correlation with schirmer test and tear-film breakup time.

Authors:  Rana Altan-Yaycioglu; Selcuk Sizmaz; Handan Canan; Muge Coban-Karatas
Journal:  Curr Eye Res       Date:  2013-03-14       Impact factor: 2.424

9.  Diurnal variation of upper and lower tear menisci.

Authors:  Meixiao Shen; Jianhua Wang; Aizhu Tao; Qi Chen; Shichu Lin; Jia Qu; Fan Lu
Journal:  Am J Ophthalmol       Date:  2008-03-04       Impact factor: 5.258

10.  Quantitative evaluation of tear meniscus height from fluorescein photographs.

Authors:  Masataka Kawai; Masakazu Yamada; Motoko Kawashima; Makoto Inoue; Eiki Goto; Yukihiko Mashima; Kazuo Tsubota
Journal:  Cornea       Date:  2007-05       Impact factor: 2.651

View more
  6 in total

Review 1.  The Growing Need for Validated Biomarkers and Endpoints for Dry Eye Clinical Research.

Authors:  Neeta S Roy; Yi Wei; Eric Kuklinski; Penny A Asbell
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-05-01       Impact factor: 4.799

Review 2.  Dry Eye Disease: Emerging Approaches to Disease Analysis and Therapy.

Authors:  Mostafa Heidari; Farsad Noorizadeh; Kevin Wu; Takenori Inomata; Alireza Mashaghi
Journal:  J Clin Med       Date:  2019-09-11       Impact factor: 4.241

3.  Correlation between type 2 diabetes, dry eye and Meibomian glands dysfunction.

Authors:  Garzón P Sandra Johanna; López-Alemany Antonio; Gené-Sampedro Andrés
Journal:  J Optom       Date:  2019-05-23

Review 4.  Automation of dry eye disease quantitative assessment: A review.

Authors:  Ikram Brahim; Mathieu Lamard; Anas-Alexis Benyoussef; Gwenolé Quellec
Journal:  Clin Exp Ophthalmol       Date:  2022-06-27       Impact factor: 4.383

Review 5.  Confocal Microscopy and Anterior Segment Optical Coherence Tomography Imaging of the Ocular Surface and Bleb Morphology in Medically and Surgically Treated Glaucoma Patients: A Review.

Authors:  Carmela Carnevale; Ivano Riva; Gloria Roberti; Manuele Michelessi; Lucia Tanga; Alice C Verticchio Vercellin; Luca Agnifili; Gianluca Manni; Alon Harris; Luciano Quaranta; Francesco Oddone
Journal:  Pharmaceuticals (Basel)       Date:  2021-06-18

6.  Correlation of Measures From the OCULUS Keratograph and Clinical Assessments of Dry Eye Disease in the Dry Eye Assessment and Management Study.

Authors:  John E Sutphin; Gui-Shuang Ying; Vatinee Y Bunya; Yinxi Yu; Meng C Lin; Kathleen McWilliams; Elizabeth Schmucker; Eric J Kuklinski; Penny A Asbell; Maureen G Maguire
Journal:  Cornea       Date:  2021-07-21       Impact factor: 3.152

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.