Literature DB >> 27423836

Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) analysis of hemodynamics in valve-sparing aortic root repair with an anatomically shaped sinus prosthesis.

Thekla H Oechtering1, Carl F Hons2, Malte Sieren2, Peter Hunold2, Anja Hennemuth3, Markus Huellebrand3, Johann Drexl3, Michael Scharfschwerdt4, Doreen Richardt4, Hans-Hinrich Sievers4, Jörg Barkhausen2, Alex Frydrychowicz2.   

Abstract

OBJECTIVE: The anatomically shaped sinus prosthesis (Uni-Graft W SINUS; Braun, Melsungen, Germany) used in valve-sparing aortic root replacement promises physiological hemodynamics believed to grant physiologic valve function. Using time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI), we analyzed sinus vortex formation and transvalvular pressure gradients in patients with sinus prosthesis compared with age-matched and young healthy volunteers.
METHODS: Twelve patients with sinus prosthesis (55 ± 15 years), 12 age-matched and 6 young healthy volunteers (55 ± 6 years, 25 ± 3 years, respectively) were examined at 3T with a 4D flow magnetic resonance imaging sequence. Sinus vortices visualized by streamlines and time-resolved particle paths were graded on a 4-point Likert scale. Time resolved pressure differences of the left ventricular outflow tract and the ascending aorta to a reference point in the aortic bulb as well as the transvalvular pressure gradient were evaluated.
RESULTS: 4D flow visualizations revealed a propensity of the sinus prosthesis toward intermediate (50%) and large (28%) vortices compared with age-matched volunteers with small (61%) and intermediate (36%) vortices. Vortices in sinus prostheses had a similar configuration compared with those in volunteers. The peak transvalvular pressure gradient did not vary significantly between patients and age-matched volunteers (4.0 ± 0.9 mm Hg, 3.8 ± 0.7 mm Hg, P = .373), its temporal evolution resembled that of volunteers with a prolonged positive phase in patients.
CONCLUSIONS: Hemodynamics closely relating to those of volunteers were confirmed in sinus prostheses, believed to grant physiological valve function. Minor differences are presumably attributed to graft compliance and temporal resolution of the acquisition. Nevertheless, long-term deterioration of valve function as it was described for straight grafts could potentially be decelerated using sinus prostheses.
Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  4D Flow MRI; 4D flow cardiovascular magnetic resonance; VSARR; sinus prosthesis; sinus vortices; sinuses of Valsalva; transvalvular pressure gradients; valve-sparing aortic root replacement

Mesh:

Year:  2016        PMID: 27423836     DOI: 10.1016/j.jtcvs.2016.04.029

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  12 in total

1.  Aortic annulus and the importance of annuloplasty.

Authors:  Pouya Youssefi; Emmanuel Lansac
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-10-07

Review 2.  New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI.

Authors:  Keiichi Itatani; Shohei Miyazaki; Tokoki Furusawa; Satoshi Numata; Sachiko Yamazaki; Kazuki Morimoto; Rina Makino; Hiroko Morichi; Teruyasu Nishino; Hitoshi Yaku
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-09-19

Review 3.  Tirone on Tirone David operation and types.

Authors:  Tirone E David
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-28

4.  Perioperative evaluation of regional aortic wall shear stress patterns in patients undergoing aortic valve and/or proximal thoracic aortic replacement.

Authors:  Emilie Bollache; Paul W M Fedak; Pim van Ooij; Ozair Rahman; S Chris Malaisrie; Patrick M McCarthy; James C Carr; Alex Powell; Jeremy D Collins; Michael Markl; Alex J Barker
Journal:  J Thorac Cardiovasc Surg       Date:  2017-11-16       Impact factor: 5.209

5.  4D flow characterization of aortic blood flow after valve sparing root reimplantation procedure.

Authors:  Nicola Galea; Filippo Piatti; Christopher Lau; Francesco Sturla; Luca Weltert; Iacopo Carbone; Ruggero De Paulis; Mario Gaudino; Leonard N Girardi
Journal:  J Vis Surg       Date:  2018-05-09

6.  Aortic valve opening and closure: the clover dynamics.

Authors:  Emmanuel Lansac; Hou-Sen Lim; Yu Shomura; Khee Hiang Lim; Nolan T Rice; Isabelle Di Centa; Pouya Youssefi; Wolfgang Goetz; Carlos M G Duran
Journal:  Ann Cardiothorac Surg       Date:  2019-05

7.  Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve.

Authors:  Daniel Z Gordon; Muhannad A Abbasi; Jeesoo Lee; Roberto Sarnari; Alireza Sojoudi; Qiao Wei; Michael B Scott; Jeremy D Collins; Bradley D Allen; Julie A Blaisdell; James C Carr; Michael Markl
Journal:  J Thorac Imaging       Date:  2020-11-01       Impact factor: 5.528

Review 8.  Hemodynamic Profiles Before and After Surgery in Bicuspid Aortic Valve Disease-A Systematic Review of the Literature.

Authors:  Daniel G W Cave; Hannah Panayiotou; Malenka M Bissell
Journal:  Front Cardiovasc Med       Date:  2021-03-24

9.  Reimplantation valve-sparing aortic root replacement is the most durable approach to facilitate aortic valve repair.

Authors:  Tirone David
Journal:  JTCVS Tech       Date:  2021-01-28

Review 10.  Leaflet immobility and thrombosis in transcatheter aortic valve replacement.

Authors:  Arnold C T Ng; David R Holmes; Michael J Mack; Victoria Delgado; Raj Makkar; Philipp Blanke; Jonathon A Leipsic; Martin B Leon; Jeroen J Bax
Journal:  Eur Heart J       Date:  2020-09-01       Impact factor: 35.855

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.