Literature DB >> 27421474

THE EFFECT OF AN OPTIMIZED IMAGING FLOW CYTOMETRY ANALYSIS TEMPLATE ON SAMPLE THROUGHPUT IN THE REDUCED CULTURE CYTOKINESIS-BLOCK MICRONUCLEUS ASSAY.

M A Rodrigues1, C E Probst2, L A Beaton-Green1, R C Wilkins3.   

Abstract

In cases of overexposure to ionizing radiation, the cytokinesis-block micronucleus (CBMN) assay can be performed in order to estimate the dose of radiation to an exposed individual. However, in the event of a large-scale radiation accident with many potentially exposed casualties, the assay must be able to generate accurate dose estimates to within ±0.5 Gy as quickly as possible. The assay has been adapted to, validated and optimized on the ImageStreamX imaging flow cytometer. The ease of running this automated version of the CBMN assay allowed investigation into the accuracy of dose estimates after reducing the volume of whole blood cultured to 200 µl and reducing the culture time to 48 h. The data analysis template used to identify binucleated lymphocyte cells (BNCs) and micronuclei (MN) has since been optimized to improve the sensitivity and specificity of BNC and MN detection. This paper presents a re-analysis of existing data using this optimized analysis template to demonstrate that dose estimations from blinded samples can be obtained to the same level of accuracy in a shorter data collection time. Here, we show that dose estimates from blinded samples were obtained to within ±0.5 Gy of the delivered dose when data collection time was reduced by 30 min at standard culture conditions and by 15 min at reduced culture conditions. Reducing data collection time while retaining the same level of accuracy in our imaging flow cytometry-based version of the CBMN assay results in higher throughput and further increases the relevancy of the CBMN assay as a radiation biodosimeter. © Crown copyright 2016.

Mesh:

Year:  2016        PMID: 27421474     DOI: 10.1093/rpd/ncw160

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Automated Triage Radiation Biodosimetry: Integrating Imaging Flow Cytometry with High-Throughput Robotics to Perform the Cytokinesis-Block Micronucleus Assay.

Authors:  Qi Wang; Matthew A Rodrigues; Mikhail Repin; Sergey Pampou; Lindsay A Beaton-Green; Jay Perrier; Guy Garty; David J Brenner; Helen C Turner; Ruth C Wilkins
Journal:  Radiat Res       Date:  2019-02-19       Impact factor: 2.841

2.  RABiT-II: Implementation of a High-Throughput Micronucleus Biodosimetry Assay on Commercial Biotech Robotic Systems.

Authors:  Mikhail Repin; Sergey Pampou; Charles Karan; David J Brenner; Guy Garty
Journal:  Radiat Res       Date:  2017-02-23       Impact factor: 2.841

3.  The in vitro micronucleus assay using imaging flow cytometry and deep learning.

Authors:  Matthew A Rodrigues; Christine E Probst; Artiom Zayats; Bryan Davidson; Michael Riedel; Yang Li; Vidya Venkatachalam
Journal:  NPJ Syst Biol Appl       Date:  2021-05-18

Review 4.  The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry.

Authors:  Ruth C Wilkins; Matthew A Rodrigues; Lindsay A Beaton-Green
Journal:  Genome Integr       Date:  2017-01-23

5.  Automation of the in vitro micronucleus assay using the Imagestream® imaging flow cytometer.

Authors:  Matthew A Rodrigues
Journal:  Cytometry A       Date:  2018-08-17       Impact factor: 4.355