Abstract

Pulse oximetry is a major improvement in the assessment of oxygenation. The device uses plethysmography and light absorbance measurements at two wavelengths to estimate oxygen saturation. It is inaccurate, however, when more than two types of hemoglobin are present. This article describes two infants with methemoglobinemia in whom pulse oximetry overestimated oxygen saturation. We discuss the mechanism of this systematic error and emphasize that pulse oximetry should not be used to estimate true oxygen saturation in the presence of methemoglobin. However, a disparity between oxygen saturation estimates by pulse oximetry and by calculations based on the arterial partial pressure of oxygen and the oxygen-hemoglobin dissociation curve can provide an important clue to the presence of such abnormal types of hemoglobins. Therapy should be based on direct measurements of oxyhemoglobin by cooximetry and not on measurements of oxygen saturation by pulse oximetry or on saturations calculated from the Pao2 and the oxyhemoglobin dissociation curve.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2741859     DOI: 10.1001/archpedi.1989.02150190095030

Source DB:  PubMed          Journal:  Am J Dis Child        ISSN: 0002-922X


  11 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

3.  A case of pseudocyanosis.

Authors:  Ruvan A I Ekanayaka
Journal:  BMJ Case Rep       Date:  2014-03-10

4.  Acute life-threatening methaemoglobinaemia following ingestion of chloroquine.

Authors:  Imran Rizvi; Shamsuz Zaman; Noorin Zaidi; Mohammed S Asif; Nasar Abdali
Journal:  BMJ Case Rep       Date:  2012-03-20

5.  NADH-diaphorase deficiency identified in a patient with congenital methaemoglobinaemia detected by pulse oximetry.

Authors:  K Sugahara; T Sadohara; T Kawaguchi; T Hirano
Journal:  Intensive Care Med       Date:  1998-07       Impact factor: 17.440

6.  Diagnostic dilemma: Low oxygen saturation during cardiac surgery.

Authors:  Suruchi Ladha; Shivani Aggarwal; Usha Kiran; Arindam Choudhary; Poonam Malhotra Kapoor; Ujjwal Kumar Choudhary
Journal:  Ann Card Anaesth       Date:  2017 Apr-Jun

7.  Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome.

Authors:  Lee S Nguyen; Marion Helias; Lisa Raia; Estelle Nicolas; Paul Jaubert; Sarah Benghanem; Zakaria Ait Hamou; Pierre Dupland; Julien Charpentier; Frédéric Pène; Alain Cariou; Jean-Paul Mira; Jean-Daniel Chiche; Mathieu Jozwiak
Journal:  Sci Rep       Date:  2022-01-27       Impact factor: 4.379

8.  A simple quantitative bedside test to determine methemoglobin.

Authors:  Fathima Shihana; Dhammika Menike Dissanayake; Nicholas Allan Buckley; Andrew Hamilton Dawson
Journal:  Ann Emerg Med       Date:  2009-10-08       Impact factor: 5.721

9.  Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

Authors:  Gavin D Perkins; Daniel F McAuley; Simon Giles; Helen Routledge; Fang Gao
Journal:  Crit Care       Date:  2003-06-11       Impact factor: 9.097

10.  Unexplained Methemoglobinemia in Coronavirus Disease 2019: A Case Report.

Authors:  Hina Faisal; Alexi Bloom; A Osama Gaber
Journal:  A A Pract       Date:  2020-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.