Literature DB >> 27408496

Plate augmentation with retention of intramedullary nail is effective for resistant femoral shaft non-union.

Raju Vaishya1, Amit Kumar Agarwal1, Nishint Gupta1, Vipul Vijay1.   

Abstract

OBJECTIVE: Non-union after intramedullary nail fixation of femur shaft fractures is although infrequent but a challenging condition to treat. The treatment options available to deal with such a situation include exchange nailing, removal of nail and re-osteosynthesis with plating, or Ilizarov fixation. We believe that rotational instability, in the presence of a nail, is one of the main reasons for most of the non-union. We present our experience of plate augmentation leaving the nail in situ for non-union of femoral shaft fracture.
METHODS: In this retrospective study, we had operated 16 cases of the femoral shaft non-union, which were treated by plate augmentation and bone grafting (if needed) with retention of the intramedullary interlocking nail in situ. The cases of infected non-union and any fracture less than one-year duration were excluded from the study.
RESULTS: Bone grafting was done only in 4 cases with atrophic non-union. We could achieve union in all the cases at an average time of 6.25 months. The average time of surgery between the primary surgery of interlocking nail fixation and the plate augmentation was 13 months. Mean surgical time for plate augmentation and bone grafting was 71 min. No major complication or implant failure was encountered. An average residual shortening of the limb was 0.9 cm and average range of motion of the knee was 115°.
CONCLUSION: Plate augmentation seems an effective, reliable, safe and an easy procedure for the treatment of femoral shaft non-union after an intramedullary nailing.

Entities:  

Keywords:  Femur; Fracture; Intramedullary nail; Non-union; Plate

Year:  2016        PMID: 27408496      PMCID: PMC4925908          DOI: 10.1016/j.jor.2016.06.003

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  19 in total

Review 1.  Femoral diaphyseal aseptic non-unions: is there an ideal method of treatment?

Authors:  Daniel J Crowley; Nikolaos K Kanakaris; Peter V Giannoudis
Journal:  Injury       Date:  2007-05       Impact factor: 2.586

2.  [Augmentative locking compression plate (LCP) combined with bone graft for the treatment of aseptic femoral shaft nonunion after intramedullary nailing].

Authors:  Fei-da Wang; Yao-zu Gao; Wei Yuan; Jin-qiang Du; Xiao-chun Wei
Journal:  Zhongguo Gu Shang       Date:  2014-10

Review 3.  Management of femoral shaft fractures.

Authors:  M V Neumann; N P Südkamp; P C Strohm
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2015       Impact factor: 0.531

4.  Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures.

Authors:  M J Weresh; R Hakanson; M D Stover; S H Sims; J F Kellam; M J Bosse
Journal:  J Orthop Trauma       Date:  2000 Jun-Jul       Impact factor: 2.512

5.  Exchange nailing for femoral shaft aseptic non-union.

Authors:  A J Furlong; P V Giannoudis; P DeBoer; S J Matthews; D A MacDonald; R M Smith
Journal:  Injury       Date:  1999-05       Impact factor: 2.586

6.  Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases.

Authors:  R A Winquist; S T Hansen; D K Clawson
Journal:  J Bone Joint Surg Am       Date:  1984-04       Impact factor: 5.284

7.  The treatment of nonunions following intramedullary nailing of femoral shaft fractures.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Ole M Böstman
Journal:  J Orthop Trauma       Date:  2002-07       Impact factor: 2.512

8.  Current Concepts: Aseptic Nonunion of Femoral Shaft Diaphysis.

Authors:  Elias Lambiris; Andreas Panagopoulos; Panagiotis Zouboulis; Efrosini Sourgiadaki
Journal:  Eur J Trauma Emerg Surg       Date:  2007-04-04       Impact factor: 3.693

9.  Operative treatment for femoral shaft nonunions, a systematic review of the literature.

Authors:  Matthijs P Somford; Michel P J van den Bekerom; Peter Kloen
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-07-27

10.  Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion.

Authors:  Christian Hierholzer; Claudio Glowalla; Michael Herrler; Christian von Rüden; Sven Hungerer; Volker Bühren; Jan Friederichs
Journal:  J Orthop Surg Res       Date:  2014-10-10       Impact factor: 2.359

View more
  4 in total

1.  Collagen/Nano-hydroxyapatite Composite Scaffold Application with Exchange Reamed Nailing Accelerates Bone Union and Improves Quality of Life in Atrophic Femoral Shaft Nonunions: A Retrospective Comparative Study.

Authors:  Nevzat Gönder; İbrahim Halil Demir; Erman Öğümsöğütlü; Volkan Kılınçoğlu
Journal:  Indian J Orthop       Date:  2021-10-19       Impact factor: 1.033

Review 2.  [Research progress of augmentation plate for femoral shaft nonunion after intramedullary nail fixation].

Authors:  Wei Zhang; Zhuo Zhang; Hua Chen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-12-15

3.  Results of revision intramedullary nailing with and without auxillary plate in aseptic trochanteric and subtrochanteric nonunion.

Authors:  Dorien Schneidmueller; Christian von Rüden; Christina Dietze; Andreas Brand; Jan Friederichs; Fabian Stuby
Journal:  Eur J Trauma Emerg Surg       Date:  2021-04-16       Impact factor: 2.374

4.  Comparing Augmentative Plating and Exchange Nailing for the Treatment of Nonunion of Femoral Shaft Fracture after Intramedullary Nailing: A Meta-analysis.

Authors:  Yao-Feng Jin; Hai-Chao Xu; Zhong-Hai Shen; Xue-Kang Pan; Hui Xie
Journal:  Orthop Surg       Date:  2020-01-01       Impact factor: 2.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.