Literature DB >> 25739246

[Augmentative locking compression plate (LCP) combined with bone graft for the treatment of aseptic femoral shaft nonunion after intramedullary nailing].

Fei-da Wang, Yao-zu Gao, Wei Yuan, Jin-qiang Du, Xiao-chun Wei.   

Abstract

OBJECTIVE: To investigate the effect of augmentative locking compression plate combined with bone graft in treating aseptic femoral shaft nonunion after intramedullary nailing.
METHODS: Twenty-one cases with aseptic femoral shaft nonunion after intramedullary nailing from January 2007 to January 2013 were treated,including 18 males and 3 females with a mean age of 37.7 years (ranged from 23 to 64 years). The mean period of nonunion after surgery was 23.9 months (ranged from 9 to 62 months). According to Weber-Cech classification,10 of those 21 cases were hypertrophic nonunion,7 were atrophic, and 4 had oligotrophic fracture nonunion. All patients retained the original intramedullary nail, and applied with augmentation plating of 6 to 8 holes locking compression plate, unicortical fixation with 2 to 3 locking screws in the proximal or distal end, with simultaneous autologous iliac bone grafting. After treatment,all patients were allowed to partial weight-bearing until full weight-bearing according to the radiological results. All patients were followed up and were evaluated with clinical and imaging results.
RESULTS: All patients were followed up from 8 to 24 months, averaged (13.5±3.5) months,which showed clinical union at 4 to 8 months, averaged (6.0±1.0) months and radiological solid union at 7 to 12 months, averaged (9.1±1.5) months. No such complications as infection,hardware loosening or breaking were found.
CONCLUSION: Augmentative locking compression plate(LCP) combined with bone graft for aseptic femoral shaft nonunion after intramedullary nail has a satisfied clinical efficacy. It's an useful and simple method.

Entities:  

Mesh:

Year:  2014        PMID: 25739246

Source DB:  PubMed          Journal:  Zhongguo Gu Shang        ISSN: 1003-0034


  3 in total

1.  Plate augmentation with retention of intramedullary nail is effective for resistant femoral shaft non-union.

Authors:  Raju Vaishya; Amit Kumar Agarwal; Nishint Gupta; Vipul Vijay
Journal:  J Orthop       Date:  2016-06-25

2.  Double locking plate fixation for femoral shaft nonunion.

Authors:  Ye Peng; Xinran Ji; Lihai Zhang; Peifu Tang
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-05-03

3.  Successful management of lower limb nonunion using locking plates and bone graft with retention of intramedullary nail.

Authors:  Hong-Jun Zhang; Shuai Wang; Yong-Hui Dong; Wen-Di Zheng; Zhe Sun; Jia Zheng
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889