Literature DB >> 27400076

Clinical Outcomes After Cataract Surgery With a New Transitional Toric Intraocular Lens.

Tiago B Ferreira, Tos T J M Berendschot, Filomena J Ribeiro.   

Abstract

PURPOSE: To evaluate the visual outcomes of patients who underwent cataract surgery with implantation of a transitional toric monofocal intraocular lens (IOL) (Precizon Toric IOL, model 565; Ophtec BV, Groningen, The Netherlands).
METHODS: In this prospective case series, 51 eyes of 39 patients with cataract and regular keratometric astigmatism between 1.00 and 4.50 diopters (D) that had phacoemulsification with implantation of a Precizon Toric IOL were included. Over a 4-month follow-up period, the main outcome measures were uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), spherical equivalent (SE) refraction, astigmatism outcomes evaluated according to the Alpins method, the IOL's rotational stability, and higher order aberrations.
RESULTS: At the 4-month follow-up visit, mean UDVA was 0.06 ± 0.1 logMAR (range: 0.4 to -0.18 logMAR) (P < .001) and mean CDVA was -0.00 ± 0.07 logMAR (range: 0.15 to -0.18 logMAR) (P < .001). UDVA was 0.3 logMAR or better in 50 (98%) eyes and 0.1 logMAR or better in 42 (82%) eyes. Mean SE refraction was -0.19 ± 0.38 D (range: -1.13 to +0.50 D), with 44 (86%) eyes within ±0.50 D of the attempted correction. Mean target induced astigmatism was 1.96 ± 0.94 D (range: 0.70 to 4.50 D) and mean surgically induced astigmatism was 1.85 ± 1.01 D (range: 0.07 to 4.64 D). Mean correction index was 0.87 (range: 0.07 to 2.29 D). Mean toric IOL axis rotation was 1.98° ± 1.78° (range: 0° to 7°). Ocular aberrometry was within normal values.
CONCLUSIONS: The implantation of the Precizon Toric IOL in patients with cataract and corneal astigmatism provided excellent visual outcomes, predictability of refractive results, rotational stability, and good optical performance. [J Refract Surg. 2016;32(7):452-458.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27400076     DOI: 10.3928/1081597X-20160428-07

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up.

Authors:  Balázs Gyöngyössy; Paul Jirak; Ulrich Schönherr
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

2.  Evaluation of Astigmatism-Correcting Efficiency and Rotational Stability after Cataract Surgery with a Double-Loop Haptic Toric Intraocular Lens: A 1-Year Follow-Up.

Authors:  Ladislav Viktor Nováček; Marie Němcová; Kateřina Tyx; Kristýna Lahodová; Leoš Rejmont; Pavel Rozsíval; Pavel Studený
Journal:  Biomed Hub       Date:  2021-02-17

3.  Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China.

Authors:  Ji-Guo Yu; Jie Zhong; Zhong-Ming Mei; Fang Zhao; Na Tao; Yi Xiang
Journal:  BMC Ophthalmol       Date:  2017-04-26       Impact factor: 2.209

Review 4.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

5.  Transitional conic toric intraocular lens for the management of corneal astigmatism in cataract surgery.

Authors:  Francisco Bandeira; Merce Morral; Daniel Elies; Sergio Eguiza; Spyridoula Souki; Felicidad Manero; Jose L Güell
Journal:  Clin Ophthalmol       Date:  2018-06-08

6.  Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial.

Authors:  Na Yeon Jung; Dong Hui Lim; Sung Soon Hwang; Joo Hyun; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2018-11-09       Impact factor: 2.209

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.