Noise-Compensated, Bias-Corrected Diffusion Weighted Endorectal Magnetic Resonance Imaging via a Stochastically Fully-Connected Joint Conditional Random Field Model.

Ameneh Boroomand, Mohammad Javad Shafiee, Farzad Khalvati, Masoom A Haider, Alexander Wong.   

Abstract

Diffusion weighted magnetic resonance imaging (DW-MR) is a powerful tool in imaging-based prostate cancer screening and detection. Endorectal coils are commonly used in DW-MR imaging to improve the signal-to-noise ratio (SNR) of the acquisition, at the expense of significant intensity inhomogeneities (bias field) that worsens as we move away from the endorectal coil. The presence of bias field can have a significant negative impact on the accuracy of different image analysis tasks, as well as prostate tumor localization, thus leading to increased inter- and intra-observer variability. Retrospective bias correction approaches are introduced as a more efficient way of bias correction compared to the prospective methods such that they correct for both of the scanner and anatomy-related bias fields in MR imaging. Previously proposed retrospective bias field correction methods suffer from undesired noise amplification that can reduce the quality of bias-corrected DW-MR image. Here, we propose a unified data reconstruction approach that enables joint compensation of bias field as well as data noise in DW-MR imaging. The proposed noise-compensated, bias-corrected (NCBC) data reconstruction method takes advantage of a novel stochastically fully connected joint conditional random field (SFC-JCRF) model to mitigate the effects of data noise and bias field in the reconstructed MR data. The proposed NCBC reconstruction method was tested on synthetic DW-MR data, physical DW-phantom as well as real DW-MR data all acquired using endorectal MR coil. Both qualitative and quantitative analysis illustrated that the proposed NCBC method can achieve improved image quality when compared to other tested bias correction methods. As such, the proposed NCBC method may have potential as a useful retrospective approach for improving the consistency of image interpretations.

Entities:  

Mesh:

Year:  2016        PMID: 27392347     DOI: 10.1109/TMI.2016.2587836

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  A Variational Level Set Approach Based on Local Entropy for Image Segmentation and Bias Field Correction.

Authors:  Jian Tang; Xiaoliang Jiang
Journal:  Comput Math Methods Med       Date:  2017-11-27       Impact factor: 2.238

2.  Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate.

Authors:  Sophie Murer; Juergen Scheidler; Ulrike L Mueller-Lisse; Marissa Helling; Michael Scherr; Ullrich G Mueller-Lisse
Journal:  Eur Radiol Exp       Date:  2019-08-14

3.  Quality Comparison of 3 Tesla multiparametric MRI of the prostate using a flexible surface receiver coil versus conventional surface coil plus endorectal coil setup.

Authors:  T Ullrich; M D Kohli; M A Ohliger; K Magudia; S S Arora; T Barrett; L K Bittencourt; D J Margolis; L Schimmöller; B Turkbey; A C Westphalen
Journal:  Abdom Radiol (NY)       Date:  2020-07-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.