Literature DB >> 27391493

Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites.

Chang-Hun Han1, Francesco Mangano, Carmen Mortellaro, Kwang-Bum Park.   

Abstract

OBJECTIVE: The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites.
METHODS: Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately. The prosthetic restorations comprised single crowns, fixed partial dentures, and fixed full arches. Primary outcomes were implant survival, stability, and complications. Implant stability was assessed at placement and at each follow-up evaluation (1 week, 3 months, and 1 year after placement): implants with an insertion torque (IT) <45 N·cm and/or with an implant stability quotient (ISQ) <70 were considered failed for immediate loading. A statistical analysis was performed.
RESULTS: Thirty implants were placed in postextraction sockets of 17 patients, and 32 implants were placed in healed sites of 22 patients. There were no statistically significant differences in ISQ values between the 2 groups, at each assessment. In total, 60 implants (96.8%) had an IT ≥45 and an ISQ ≥70 at placement and at each follow-up control: all these implants were successfully loaded. Only 2 implants (1 in a postextraction socket and 1 in a healed site, 3.2%) could not achieve an IT ≥45 N·cm and/or an ISQ ≥70 at placement or over time: accordingly, these were considered failed for stability, as they could not be subjected to immediate loading. One of these 2 implants, in a healed site of a posterior maxilla, had to be removed, yielding an overall 1-year implant survival rate of 98.4%. No complications were reported. No significant differences were reported between the 2 groups with respect to implant failures and complications.
CONCLUSION: Immediately loaded implants placed in postextraction sockets and healed sites had similar high survival and stability, with no reported complications. Further long-term studies on larger samples of patients are needed to confirm these results.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27391493     DOI: 10.1097/SCS.0000000000002756

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  10 in total

1.  Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: a randomized, controlled histologic and histomorphometric study in the human posterior maxilla.

Authors:  Francesco Guido Mangano; Giovanna Iezzi; Jamil Awad Shibli; Jefferson Trabach Pires; Giuseppe Luongo; Adriano Piattelli; Carlo Mangano
Journal:  Clin Oral Investig       Date:  2017-02-02       Impact factor: 3.573

2.  Alveolar Ridge Reconstruction with Titanium Meshes and Simultaneous Implant Placement: A Retrospective, Multicenter Clinical Study.

Authors:  Raquel Zita Gomes; Andres Paraud Freixas; Chang-Hun Han; Sohueil Bechara; Isaac Tawil
Journal:  Biomed Res Int       Date:  2016-11-23       Impact factor: 3.411

3.  Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone.

Authors:  Francesco Mangano; Mario Raspanti; Hassan Maghaireh; Carlo Mangano
Journal:  Materials (Basel)       Date:  2017-12-17       Impact factor: 3.623

4.  Immediate Loading of Single Implants in the Anterior Maxilla: A 1-Year Prospective Clinical Study on 34 Patients.

Authors:  Miguel Stanley; Filipa Calheiros Braga; Beatriz Mota Jordao
Journal:  Int J Dent       Date:  2017-05-22

5.  Implant Stability in the Posterior Maxilla: A Controlled Clinical Trial.

Authors:  Raquel Zita Gomes; Mario Ramalho de Vasconcelos; Isabel Maria Lopes Guerra; Rute Alexandra Borges de Almeida; Antonio Cabral de Campos Felino
Journal:  Biomed Res Int       Date:  2017-05-25       Impact factor: 3.411

6.  Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study.

Authors:  Soheil Bechara; Algirdas Lukosiunas; Giorgio Andrea Dolcini; Ricardas Kubilius
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

7.  Immediate functional loading of single implants: a multicenter study with 4 years of follow-up.

Authors:  Filiep Raes; Tammaro Eccellente; Carolina Lenzi; Michele Ortolani; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

8.  The Root Membrane Technique: Human Histologic Evidence after Five Years of Function.

Authors:  Miltiadis E Mitsias; Konstantinos D Siormpas; Georgios A Kotsakis; Scott D Ganz; Carlo Mangano; Giovanna Iezzi
Journal:  Biomed Res Int       Date:  2017-11-22       Impact factor: 3.411

9.  Early Bone Formation around Immediately Loaded Transitional Implants Inserted in the Human Posterior Maxilla: The Effects of Fixture Design and Surface.

Authors:  Carlo Mangano; Jamil Awad Shibli; Jefferson Trabach Pires; Giuseppe Luongo; Adriano Piattelli; Giovanna Iezzi
Journal:  Biomed Res Int       Date:  2017-02-09       Impact factor: 3.411

10.  Tapered, Double-Lead Threads Single Implants Placed in Fresh Extraction Sockets and Healed Sites of the Posterior Jaws: A Multicenter Randomized Controlled Trial with 1 to 3 Years of Follow-Up.

Authors:  Alessandro Cucchi; Elisabetta Vignudelli; Simonetta Franco; Luca Levrini; Dario Castellani; Luca Pagliani; Massimiliano Rea; Claudio Modena; Giulio Sandri; Carlo Longhi
Journal:  Biomed Res Int       Date:  2017-09-13       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.