Literature DB >> 27388432

Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel-titanium instruments.

J-J Cai1, X-N Tang1, J-Y Ge1.   

Abstract

AIM: To investigate the effect of irrigation on the surface roughness and fatigue resistance of HyFlex and M3 controlled memory (CM) wire nickel-titanium instruments.
METHODOLOGY: Two new files of each brand were analysed by atomic force microscopy (AFM). Then, the instruments were dynamically immersed in either 5.25% sodium hypochlorite (NaOCl) or 17% ethylene diamine tetraacetic acid (EDTA) solution for 10 min, followed by AFM analysis. The roughness average (Ra) and root mean square (RMS) values were analysed statistically using an independent sample t-test. Then, 36 files of each brand were randomly assigned to three groups (n = 12). Group 1 (the control group) was composed of new instruments. Groups 2 and 3 were dynamically immersed in 5.25% NaOCl and 17% EDTA solutions for 10 min, respectively. The number of rotations to failure for various groups was analysed using the one-way analysis of variance software.
RESULTS: For M3 files, the Ra and RMS values significantly increased (P < 0.05) after the immersion. For the HyFlex file, the Ra and RMS values significantly increased (P < 0.05) only in EDTA, but not (P > 0.05) NaOCl. The resistance to cyclic fatigue of both HyFlex and M3 files did not significantly decrease (P > 0.05) by immersing in 5.25% NaOCl and 17% EDTA solutions.
CONCLUSIONS: Except the HyFlex files immersed in NaOCl, the surface roughness of other files exposed to irrigants increased. However, a change in the surface tomography of CM wire instruments caused by contact with irrigants for 10 min did not trigger a decrease in cyclic fatigue resistance.
© 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  atomic force microscopy; controlled memory wire nickel-titanium instruments; cyclic fatigue resistance; irrigation

Mesh:

Substances:

Year:  2016        PMID: 27388432     DOI: 10.1111/iej.12676

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Effect of NaOCl and EDTA irrigating solutions on the cyclic fatigue resistance of EdgeTaper Platinum instruments.

Authors:  Hussam Alfawaz; Abdullah Alqedairi; Maha Alhamdan; Najla Alkhzim; Shatha Alfarraj; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

3.  Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature.

Authors:  Wafaa A Khalil; Zuhair S Natto
Journal:  Restor Dent Endod       Date:  2019-04-26

4.  Qualitative Assessment of the Surface Topographic Changes of XP-endo Shaper and TruNatomy files after exposure to Sodium Hypochlorite and Ethylenediaminetetraacetic Acid.

Authors:  Jerry Jose; Akshay Khandelwal; Riluwan Siddique
Journal:  Eur Endod J       Date:  2021-08

Review 5.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  5 in total