Literature DB >> 27385636

Amide proton transfer imaging of brain tumors using a self-corrected 3D fast spin-echo dixon method: Comparison With separate B0 correction.

Osamu Togao1, Jochen Keupp2, Akio Hiwatashi1, Koji Yamashita1, Kazufumi Kikuchi1, Masami Yoneyama3, Hiroshi Honda1.   

Abstract

PURPOSE: To assess the quantitative performance of three-dimensional (3D) fast spin-echo (FSE) Dixon amide proton transfer (APT) imaging of brain tumors compared with B0 correction with separate mapping methods.
METHODS: Twenty-two patients with brain tumors (54.2 ± 18.7 years old, 12 males and 10 females) were scanned at 3 Tesla (T). Z-spectra were obtained at seven different frequency offsets at ±3.1 ppm, ± 3.5 ppm, ± 3.9 ppm, and -1560 ppm. The scan was repeated three times at +3.5 ppm with echo shifts for Dixon B0 mapping. The APT image corrected by a three-point Dixon-type B0 map from the same scan (3D-Dixon) or a separate B0 map (2D-separate and 3D-separate), and an uncorrected APT image (3D-uncorrected) were generated. We compared the APT-weighted signals within a tumor obtained with each 3D method with those obtained with 2D-separate as a reference standard.
RESULTS: Excellent agreements and correlations with the 2D-separate were obtained by the 3D-Dixon method for both mean (ICC = 0.964, r = 0.93, P < 0.0001) and 90th-percentile (ICC = 0.972, r = 0.95, P < 0.0001) APT-weighted signals. These agreements and correlations for 3D-Dixon were better than those obtained by the 3D-uncorrected and 3D-separate methods.
CONCLUSION: The 3D FSE Dixon APT method with intrinsic B0 correction offers a quantitative performance that is similar to that of established two-dimensional (2D) methods. Magn Reson Med 77:2272-2279, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  Dixon; amide proton transfer (APT) imaging; brain tumor; chemical exchange saturation transfer (CEST)

Mesh:

Substances:

Year:  2016        PMID: 27385636     DOI: 10.1002/mrm.26322

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.

Authors:  Johannes Windschuh; Moritz Zaiss; Philipp Ehses; Jae-Seung Lee; Alexej Jerschow; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2018-05-31       Impact factor: 4.668

2.  Prediction of H3K27M-mutant brainstem glioma by amide proton transfer-weighted imaging and its derived radiomics.

Authors:  Zhizheng Zhuo; Liying Qu; Peng Zhang; Liwei Zhang; Yaou Liu; Yunyun Duan; Dan Cheng; Xiaolu Xu; Ting Sun; Jinli Ding; Cong Xie; Xing Liu; Sven Haller; Frederik Barkhof
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-06-16       Impact factor: 9.236

3.  MRI detection of bacterial brain abscesses and monitoring of antibiotic treatment using bacCEST.

Authors:  Jing Liu; Renyuan Bai; Yuguo Li; Verena Staedtke; Shuixing Zhang; Peter C M van Zijl; Guanshu Liu
Journal:  Magn Reson Med       Date:  2018-03-25       Impact factor: 4.668

4.  Amide proton transfer imaging for differentiation of tuberculomas from high-grade gliomas: Preliminary experience.

Authors:  Karthik Kulanthaivelu; Shumyla Jabeen; Jitender Saini; Sanita Raju; Atchayaram Nalini; Nishanth Sadashiva; Shashank Hegde; Narayana Krishna Rolla; Indrajit Saha; Netravathi M; Seena Vengalil; Saikrishna Swaroop; Shilpa Rao
Journal:  Neuroradiol J       Date:  2021-04-07

5.  Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition.

Authors:  Ran Sui; Lin Chen; Yuguo Li; Jianpan Huang; Kannie W Y Chan; Xiang Xu; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2021-03-27       Impact factor: 3.737

6.  A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

Authors:  Esau Poblador Rodriguez; Philipp Moser; Barbara Dymerska; Simon Robinson; Benjamin Schmitt; Andre van der Kouwe; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

7.  Amide Proton Transfer Contrast Distribution in Different Brain Regions in Young Healthy Subjects.

Authors:  Thomas Sartoretti; Elisabeth Sartoretti; Michael Wyss; Árpád Schwenk; Arash Najafi; Christoph Binkert; Carolin Reischauer; Jinyuan Zhou; Shanshan Jiang; Anton S Becker; Sabine Sartoretti-Schefer
Journal:  Front Neurosci       Date:  2019-05-22       Impact factor: 4.677

8.  3D gradient echo snapshot CEST MRI with low power saturation for human studies at 3T.

Authors:  Anagha Deshmane; Moritz Zaiss; Tobias Lindig; Kai Herz; Mark Schuppert; Chirayu Gandhi; Benjamin Bender; Ulrike Ernemann; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2018-11-15       Impact factor: 4.668

9.  Feasibility evaluation of amide proton transfer-weighted imaging in the parotid glands: a strategy to recognize artifacts and measure APT value.

Authors:  Yu Chen; Xiaoqi Wang; Tong Su; Zhentan Xu; Yunting Wang; Zhuhua Zhang; Huadan Xue; Zhizheng Zhuo; Yuanli Zhu; Zhengyu Jin; Tao Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-06

10.  Imaging glioma biology: spatial comparison of amino acid PET, amide proton transfer, and perfusion-weighted MRI in newly diagnosed gliomas.

Authors:  S Schön; J Cabello; F Liesche-Starnecker; M Molina-Romero; P Eichinger; M Metz; I Karimov; C Preibisch; J Keupp; A Hock; B Meyer; W Weber; C Zimmer; T Pyka; I Yakushev; J Gempt; B Wiestler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-01-17       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.