Literature DB >> 27380307

Fully parametric imaging with reversible tracer 18F-FLT within a reasonable time.

Nobuyuki Kudomi1, Yukito Maeda2, Tetsuhiro Hatakeyama3, Yuka Yamamoto4, Yoshihiro Nishiyama4.   

Abstract

PET enables quantitative imaging of the rate constants K 1, k 2, k 3, and k 4, with a reversible two tissue compartment model (2TCM). A new method is proposed for computing all of these rates within a reasonable time, less than 1 min. A set of differential equations for the reversible 2TCM was converted into a single formula consisting of differential and convolution terms. The validity was tested on clinical data with 18F-FLT PET for patients with glioma (n = 39). Parametric images were generated with the formula that was developed. Parametric values were extracted from regions of interest (ROIs) for glioma from the images generated, and they were compared with those obtained with the non-linear fitting method. We performed simulation studies for testing accuracy by generating simulated images, assuming clinically expected ranges of the parametric values. The computation time was about 20 s, and the quality of the images generated was acceptable. The values obtained for K 1 for grade IV tumor were 0.24 ± 0.23 and 0.26 ± 0.25 ml-1 min-1 g-1 for the image-based and ROI-based methods, respectively. The values were 0.21 ± 0.12 and 0.21 ± 0.12 min-1 for k 2, 0.13 ± 0.07 and 0.13 ± 0.07 min-1 for k 3, and 0.052 ± 0.020 and 0.054 ± 0.021 min-1 for k 4. The differences between the methods were not significant. Regression analysis showed correlations of r = 0.94, 0.86, 0.71, and 0.52 for these parameters. Simulation demonstrated that the accuracy was within acceptable ranges, namely, the correlations were r = 0.99, r = 0.97, r = 0.99, and r = 0.91 for K 1, k 2, k 3, and k 4, respectively, between estimated and assumed values. This results suggest that parametric images can be obtained fully within reasonable time, accuracy, and quality.

Entities:  

Keywords:  PET; Parametric imaging; Reversible tracer

Mesh:

Substances:

Year:  2016        PMID: 27380307     DOI: 10.1007/s12194-016-0367-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  20 in total

1.  Fast formation of statistically reliable FDG parametric images based on clustering and principal components.

Authors:  Y Kimura; M Senda; N M Alpert
Journal:  Phys Med Biol       Date:  2002-02-07       Impact factor: 3.609

2.  Strategies to improve neuroreceptor parameter estimation by linear regression analysis.

Authors:  Masanori Ichise; Hiroshi Toyama; Robert B Innis; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2002-10       Impact factor: 6.200

Review 3.  PET kinetic analysis--compartmental model.

Authors:  Hiroshi Watabe; Yoko Ikoma; Yuichi Kimura; Mika Naganawa; Miho Shidahara
Journal:  Ann Nucl Med       Date:  2006-11       Impact factor: 2.668

4.  Kinetic analysis of 3'-deoxy-3'-18F-fluorothymidine in patients with gliomas.

Authors:  Mark Muzi; Alexander M Spence; Finbarr O'Sullivan; David A Mankoff; Joanne M Wells; John R Grierson; Jeanne M Link; Kenneth A Krohn
Journal:  J Nucl Med       Date:  2006-10       Impact factor: 10.057

5.  Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.

Authors:  Hiroshi Watabe; Hiroshi Jino; Naoki Kawachi; Noboru Teramoto; Takuya Hayashi; Youichiro Ohta; Hidehiro Iida
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

6.  Performance comparison of parameter estimation techniques for the quantitation of local cerebral blood flow by dynamic positron computed tomography.

Authors:  R A Koeppe; J E Holden; W R Ip
Journal:  J Cereb Blood Flow Metab       Date:  1985-06       Impact factor: 6.200

7.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations.

Authors:  C S Patlak; R G Blasberg
Journal:  J Cereb Blood Flow Metab       Date:  1985-12       Impact factor: 6.200

8.  Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects.

Authors:  J Logan; J S Fowler; N D Volkow; A P Wolf; S L Dewey; D J Schlyer; R R MacGregor; R Hitzemann; B Bendriem; S J Gatley
Journal:  J Cereb Blood Flow Metab       Date:  1990-09       Impact factor: 6.200

9.  Kinetic modelling using basis functions derived from two-tissue compartmental models with a plasma input function: general principle and application to [18F]fluorodeoxyglucose positron emission tomography.

Authors:  Young T Hong; Tim D Fryer
Journal:  Neuroimage       Date:  2010-02-13       Impact factor: 6.556

10.  Schizophrenia is associated with elevated amphetamine-induced synaptic dopamine concentrations: evidence from a novel positron emission tomography method.

Authors:  A Breier; T P Su; R Saunders; R E Carson; B S Kolachana; A de Bartolomeis; D R Weinberger; N Weisenfeld; A K Malhotra; W C Eckelman; D Pickar
Journal:  Proc Natl Acad Sci U S A       Date:  1997-03-18       Impact factor: 11.205

View more
  3 in total

Review 1.  Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives.

Authors:  Antonia Dimitrakopoulou-Strauss; Leyun Pan; Christos Sachpekidis
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-05-19       Impact factor: 9.236

2.  Region- and voxel-based quantification in human brain of [18F]LSN3316612, a radioligand for O-GlcNAcase.

Authors:  Jae-Hoon Lee; Mattia Veronese; Jeih-San Liow; Cheryl L Morse; Jose A Montero Santamaria; Mohammad B Haskali; Sami S Zoghbi; Victor W Pike; Robert B Innis; Paolo Zanotti-Fregonara
Journal:  EJNMMI Res       Date:  2021-04-01       Impact factor: 3.138

3.  Phantom Validation of a Conservation of Activity-Based Partial Volume Correction Method for Arterial Input Function in Dynamic PET Imaging.

Authors:  Brandon Driscoll; Tina Shek; Douglass Vines; Alex Sun; David Jaffray; Ivan Yeung
Journal:  Tomography       Date:  2022-03-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.