| Literature DB >> 27379052 |
Xia Yu1, Yunting Gu1, Guanglu Jiang1, Yifeng Ma1, Liping Zhao1, Zhaogang Sun1, Paras Jain2, Max O'Donnell3, Michelle Larsen2, William R Jacobs4, Hairong Huang1.
Abstract
A novel method for detecting drug resistance in Mycobacterium tuberculosis using mycobacteriophage Φ (2) GFP10 was evaluated with clinical isolates. The phage facilitates microscopic fluorescence detection due to the high expression of green fluorescence protein which also simplifies the operative protocol as well. A total of 128 clinical isolates were tested by the phage assay for isoniazid (INH), rifampin (RIF), and streptomycin (STR) resistance while conventional drug susceptibility test, by MGIT960, was used as reference. The sensitivities of Φ (2) GFP10 assay for INH, RIF, and STR resistance detection were 100, 98.2, and 89.3%, respectively while their specificities were 85.1, 98.6, and 95.8%, respectively. The agreement between phage and conventional assay for detecting INH, RIF, and STR resistance was 92.2, 98.4, and 93.0%, respectively. The Φ (2) GFP10-phage results could be available in 2 days for RIF and STR, while it takes 3 days for INH, with an estimated cost of less than $2 to test all the three antibiotics. The Φ (2) GFP10-phage method has the potential to be a valuable, rapid and economical screening method for detecting drug-resistant tuberculosis.Entities:
Keywords: diagnosis; drug resistance; mycobacteriophage; tuberculosis; Φ2GFP10
Year: 2016 PMID: 27379052 PMCID: PMC4911409 DOI: 10.3389/fmicb.2016.00922
Source DB: PubMed Journal: Front Microbiol ISSN: 1664-302X Impact factor: 5.640
Figure 1Technique route of the study.
Results and performance parameters: assay by microscopy vs. MGIT960 system.
| INH | 61 | 0 | 10 | 57 | 128 | 100.0 (92.6–100.0) | 85.1 (73.8–92.2) | 85.9 (75.2–92.7) | 100.0 (92.1–100.0) |
| RIF | 55 | 1 | 1 | 71 | 128 | 98.2 (89.2–99.9) | 98.6 (91.5–99.9) | 98.2 (89.2–99.9) | 198.6 (91.5–99.9) |
| STR | 50 | 6 | 3 | 69 | 128 | 89.3 (77.4–95.6) | 95.8(87.5–98.9) | 94.3 (83.4–98.5) | 92.0 (82.8–96.7) |
R, resistant; S, sensitive.
The stability and precision of fluorescent microplate reader assay.
| H37Rv | 0 | 5476.00 ± 342.39 | 9902.00 ± 503.95 | 6926.00 ± 84.44 (32.76) | 6296.00 ± 267.82 (18.53) | 6540.00 ± 256.12 (24.04) |
| 4 | 5336.00 ± 359.35 | 9626.00 ± 515.10 | 6792.00 ± 181.30 (33.94) | 6974.00 ± 323.77 (26.53) | 6766.00 ± 253.24 (33.33) | |
| 24 | 5218.00 ± 299.03 | 10088.00 ± 624.40 | 6414.00 ± 283.16 (24.60) | 6364.00 ± 335.01 (23.53) | 6476.00 ± 302.62 (25.83) | |
| 14031 | 0 | 5144.00 ± 184.07 | 8650.00 ± 347.20 | 8058.00 ± 297.19 (83.11) | 8688.00 ± 413.55 (108.08) | 8314.00 ± 533.32 (90.42) |
| 4 | 5140.00 ± 252.59 | 8410.00 ± 312.17 | 7992.00 ± 342.15 (87.22) | 8302.00 ± 452.46 (97.70) | 8352.00 ± 448.74 (98.23) | |
| 24 | 5318.00 ± 332.60 | 8558.00 ± 257.04 | 8230.00 ± 278.57 (89.88) | 8470.00 ± 527.4 (97.28) | 8516.00 ± 310.85 (98.70) | |
| 14161 | 0 | 4568.00 ± 273.17 | 8354.00 ± 417.17 | 7694.00 ± 327.46 (82.57) | 5380.00 ± 185.07 (21.45) | 7612.00 ± 353.09 (80.40) |
| 4 | 4576.00 ± 298.63 | 8338.00 ± 363.00 | 7566.00 ± 458.34 (79.48) | 5768.00 ± 206.57 (31.69) | 7650.00 ± 401.25 (81.71) | |
| 24 | 4688.00 ± 80.44 | 8502.00 ± 378.31 | 7948.00 ± 382.84 (85.47) | 5320.00 ± 257.97 (16.57) | 7884.00 ± 477.94 (83.80) | |
Remaining fluorescence rate (RFR) = (reaction -blank)/(positive control–blank) × 100% (“reaction” indicates the well with drug exposure; “blank” indicates the well without drug and phage; “positive control” indicates the reaction without drug).
Results and performance parameters: vs. MGIT960 system.
| INH | 0.957 | 55.00 | 86.9 (75.2–93.8) | 94.0 (84.7–98.1) | 93.0 (82.2–97.7) | 88.7 (78.5–94.7) |
| RIF | 0.960 | 53.60 | 89.3 (77.4–95.6) | 90.3 (80.4–95.7) | 87.7 (75.7–94.5) | 91.5 (81.9–96.5) |
| STR | 0.917 | 48.65 | 83.9 (71.2–91.9) | 87.5 (77.1–93.8) | 83.9 (71.2–91.9) | 87.5 (77.1–93.8) |
Figure 2Receiver operating characteristic curves of fluorescent microplate reader in detecting drug resistance according to BactecMGIT 960 system. (A) INH; (B) RIF; (C) STR.
Results and performance parameters by sectional outcomes interpretation: vs. MGIT960 system.
| INH | <45% | 51 | 1 | 50 |
| 45–60% | 23 | 10 | 13 | |
| >60% | 54 | 50 | 4 | |
| RIF | <45% | 56 | 1 | 55 |
| 45–60% | 25 | 9 | 16 | |
| >60% | 47 | 46 | 1 | |
| STR | <45% | 64 | 8 | 56 |
| 45–60% | 21 | 7 | 14 | |
| >60% | 43 | 41 | 2 | |
R, resistant; S, sensitive; RFR, remaining fluorescence rate.