A new technique for MR elastography of the supraspinatus muscle: A gradient-echo type multi-echo sequence.

Daiki Ito1, Tomokazu Numano2, Kazuyuki Mizuhara3, Koichi Takamoto4, Takaaki Onishi1, Hisao Nishijo5.   

Abstract

Magnetic resonance elastography (MRE) can measure tissue stiffness quantitatively and noninvasively. Supraspinatus muscle injury is a significant problem among throwing athletes. The purpose of this study was to develop an MRE technique for application to the supraspinatus muscle by using a conventional magnetic resonance imaging (MRI). MRE acquisitions were performed with a gradient-echo type multi-echo MR sequence at 100Hz pneumatic vibration. A custom-designed vibration pad was used as a pneumatic transducer in order to adapt to individual shoulder shapes. In a gradient-echo type multi-echo MR sequence, without motion encoding gradient (MEG) that synchronizes with vibrations, bipolar readout gradient lobes achieved a similar function to MEG (MEG-like effect). In other words, a dedicated MRE sequence (built-in MEG) is not always necessary for MRE. In this study, 7 healthy volunteers underwent MRE. We investigated the effects of direction of the MEG-like effect and selected imaging planes on the patterns of wave propagation (wave image). The results indicated that wave images showed clear wave propagation on a condition that the direction of the MEG-like effect was nearly perpendicular to the long axis of the supraspinatus muscle, and that the imaging plane was superior to the proximal supraspinatus muscle. This limited condition might be ascribed to specific features of fibers in the supraspinatus muscle and wave reflection from the boundaries of the supraspinous fossa. The mean stiffness of the supraspinatus muscle was 10.6±3.17kPa. Our results demonstrated that using MRE, our method can be applied to the supraspinatus muscle by using conventional MRI.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  MR elastography; Muscle; Muscle fiber; Shoulder; Stiffness; Supraspinatus

Mesh:

Year:  2016        PMID: 27374984     DOI: 10.1016/j.mri.2016.06.003

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Fast acquisition of propagating waves in humans with low-field MRI: Toward accessible MR elastography.

Authors:  Maksym Yushchenko; Mathieu Sarracanie; Najat Salameh
Journal:  Sci Adv       Date:  2022-09-09       Impact factor: 14.957

2.  Quantification of the Elastic Property of Normal Thigh Muscles Using MR Elastography: Our Initial Experience.

Authors:  Junghoon Kim; Jeong Ah Ryu; Juhan Lee
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-07-28

3.  Musculoskeletal application and validation of speckle-tracking ultrasonography.

Authors:  Lars Henrik Frich; Kate Lykke Lambertsen; John Hjarbaek; Jordi Sanchez Dahl; Anders Holsgaard-Larsen
Journal:  BMC Musculoskelet Disord       Date:  2019-05-04       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.