Literature DB >> 27369051

Comparison of image quality and patient discomfort in prostate MRI: pelvic phased array coil vs. endorectal coil.

Borna K Barth1, Alexander Cornelius2, Daniel Nanz1, Daniel Eberli3, Olivio F Donati4.   

Abstract

PURPOSE: To compare image quality (IQ) and patient discomfort during prostate MRI using a pelvic phased array (PPA) coil and an endorectal (ER) coil.
MATERIALS AND METHODS: Ninety-eight patients (median age, 65.7; range 42.1-78.1) underwent prostate MRI on a 3T scanner including T2w and DWI acquired with PPA and an ER coil within the same exam. Acquisition time was kept similar for both acquisitions. Two radiologists evaluated aspects of IQ on a 5-point Likert scale and classified image artifacts. All patients completed a questionnaire on discomfort/pain regarding the ER coil using a visual analogue scale from 1 to 10.
RESULTS: There was no significant difference in overall IQ for T2w images for both readers (reader 1, 3.27 ± 0.91 and 3.07 ± 0.84, p = 0.057; reader 2, 3.70 ± 0.75 and 3.77 ± 0.81, p = 0.555) for PPA and ER coils, respectively. Overall IQ for DWI acquired with PPA and ER coils was rated similar by reader 1 (3.03 ± 1.10 and 3.08 ± 0.80, respectively, (p = 0.67)), while reader 2 preferred ER coil images (3.27 ± 0.81 and 3.66 ± 0.85 (p < 0.05)). Susceptibility artifacts were more frequent in ER than in PPA coil images (109 vs. 75). Discomfort and pain experienced during insertion of the ER coil was low altogether (VAS score, 3.5 ± 2.1 for "discomfort" and 2.4 ± 2.4 for "pain").
CONCLUSION: T2-weighted images may be acquired with comparable IQ using a PPA coil as compared to an ER coil, while DWI images showed better IQ using the ER coil for one of two readers. The insertion of the ER coil caused low to moderate discomfort and pain in patients.

Entities:  

Keywords:  Endorectal coil; Patient discomfort; Prostate MRI; Prostate cancer

Mesh:

Year:  2016        PMID: 27369051     DOI: 10.1007/s00261-016-0819-3

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  10 in total

1.  Detection of Clinically Significant Prostate Cancer: Short Dual-Pulse Sequence versus Standard Multiparametric MR Imaging-A Multireader Study.

Authors:  Borna K Barth; Pieter J L De Visschere; Alexander Cornelius; Carlos Nicolau; Hebert Alberto Vargas; Daniel Eberli; Olivio F Donati
Journal:  Radiology       Date:  2017-03-27       Impact factor: 11.105

Review 2.  Prostate MRI: Is Endorectal Coil Necessary?-A Review.

Authors:  Grace Lee; Aytekin Oto; Mihai Giurcanu
Journal:  Life (Basel)       Date:  2022-04-11

3.  Diagnostic Accuracy of a MR Protocol Acquired with and without Endorectal Coil for Detection of Prostate Cancer: A Multicenter Study.

Authors:  Borna K Barth; Niels J Rupp; Alexander Cornelius; Daniel Nanz; Rainer Grobholz; Martin Schmidtpeter; Peter J Wild; Daniel Eberli; Olivio F Donati
Journal:  Curr Urol       Date:  2019-03-08

Review 4.  Magnetic resonance imaging in active surveillance-a modern approach.

Authors:  Francesco Giganti; Caroline M Moore
Journal:  Transl Androl Urol       Date:  2018-02

5.  VERDICT MRI for Prostate Cancer: Intracellular Volume Fraction versus Apparent Diffusion Coefficient.

Authors:  Edward W Johnston; Elisenda Bonet-Carne; Uran Ferizi; Ben Yvernault; Hayley Pye; Dominic Patel; Joey Clemente; Wivijin Piga; Susan Heavey; Harbir S Sidhu; Francesco Giganti; James O'Callaghan; Mrishta Brizmohun Appayya; Alistair Grey; Alexandra Saborowska; Sebastien Ourselin; David Hawkes; Caroline M Moore; Mark Emberton; Hashim U Ahmed; Hayley Whitaker; Manuel Rodriguez-Justo; Alexander Freeman; David Atkinson; Daniel Alexander; Eleftheria Panagiotaki; Shonit Punwani
Journal:  Radiology       Date:  2019-04-02       Impact factor: 11.105

Review 6.  Evolution of prostate MRI: from multiparametric standard to less-is-better and different-is better strategies.

Authors:  Rossano Girometti; Lorenzo Cereser; Filippo Bonato; Chiara Zuiani
Journal:  Eur Radiol Exp       Date:  2019-01-28

7.  Impact of different phased-array coils on the quality of prostate magnetic resonance images.

Authors:  Daniel Stocker; Andrei Manoliu; Anton S Becker; Borna K Barth; Daniel Nanz; Markus Klarhöfer; Olivio F Donati
Journal:  Eur J Radiol Open       Date:  2021-02-03

8.  Prostate MRI using a rigid two-channel phased-array endorectal coil: comparison with phased array coil acquisition at 3 T.

Authors:  Sara Lewis; Aasrith Ganti; Pamela Argiriadi; Ally Rosen; Stefanie Hectors; Sahar Semaan; Christopher Song; Steve Peti; Maxwell Segall; Kezia George; Vaneela Jaikaran; Sebastian Villa; David Kestenbaum; Nicholas Voutsinas; John Doucette; Ashutosh Tewari; Ardeshir R Rastinehad; Bachir Taouli
Journal:  Cancer Imaging       Date:  2022-03-16       Impact factor: 3.909

9.  Factors Influencing Variability in the Performance of Multiparametric Magnetic Resonance Imaging in Detecting Clinically Significant Prostate Cancer: A Systematic Literature Review.

Authors:  Armando Stabile; Francesco Giganti; Veeru Kasivisvanathan; Gianluca Giannarini; Caroline M Moore; Anwar R Padhani; Valeria Panebianco; Andrew B Rosenkrantz; Georg Salomon; Baris Turkbey; Geert Villeirs; Jelle O Barentsz
Journal:  Eur Urol Oncol       Date:  2020-03-17

Review 10.  Prostate MRI quality: a critical review of the last 5 years and the role of the PI-QUAL score.

Authors:  Francesco Giganti; Veeru Kasivisvanathan; Alex Kirkham; Shonit Punwani; Mark Emberton; Caroline M Moore; Clare Allen
Journal:  Br J Radiol       Date:  2021-07-08       Impact factor: 3.039

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.