Literature DB >> 27366363

Assessment of the Ability of Anaesthetists to Locate the Internal Jugular Vein by the Anatomic Landmark Technique with Ultrasonography: Right or Left, Does it Make any Difference?

Jülide Ergil1, Mustafa Özmen1, Taylan Akkaya1, Derya Özkan1, Haluk Gümüş1.   

Abstract

OBJECTIVE: To assess senior and junior anaesthetists' ability to locate the right and left jugular vein (IJV) using the anatomic landmark technique.
METHODS: A total of 45 anaesthetists were included in this study. Initially, a questionnaire assessing the experiences of the anaesthetists was completed. The anaesthetists were grouped into two groups, junior and senior. The anaesthetists, who were blind to the screen, were asked to point to the internal jugular vein bilaterally on the neck of a healthy volunteer using an ultrasound probe with the midpoint as an 'imaginary needle'. The success rates for locating the right and left IJV in both junior and senior groups were assessed separately.
RESULTS: The success rate for locating the right IJV was 88% (n=26, 23/26) in the senior and 68.4% (n=19, 13/19) in the junior group (p<0.001). The success rate for locating the left IJV was 69% (18/26) in the senior and 78% (15/19) in the junior group (p<0.001), while the difference in success rates for locating the right and left IJV in the senior group was found to be statistically significant (p<0.001).
CONCLUSION: Both use of the anatomic landmark technique and experience increased the success rate. Especially in the less preferred left IJV catheterization, use of the anatomic landmark technique independent of the experience factor could increase the success rate.

Keywords:  Internal jugular vein; anesthesia training; landmark technique; ultrasound

Year:  2013        PMID: 27366363      PMCID: PMC4894092          DOI: 10.5152/TJAR.2013.34

Source DB:  PubMed          Journal:  Turk J Anaesthesiol Reanim        ISSN: 2149-276X


  9 in total

Review 1.  Preventing complications of central venous catheterization.

Authors:  David C McGee; Michael K Gould
Journal:  N Engl J Med       Date:  2003-03-20       Impact factor: 91.245

Review 2.  Injuries and liability related to central vascular catheters: a closed claims analysis.

Authors:  Karen B Domino; T Andrew Bowdle; Karen L Posner; Pete H Spitellie; Lorri A Lee; Frederick W Cheney
Journal:  Anesthesiology       Date:  2004-06       Impact factor: 7.892

3.  The ability of anaesthetists to identify the position of the right internal jugular vein correctly using anatomical landmarks.

Authors:  C R Harber; D J R Harvey; M D Wiles; D G Bogod
Journal:  Anaesthesia       Date:  2010-09       Impact factor: 6.955

4.  A survey of the use of ultrasound during central venous catheterization.

Authors:  Peter L Bailey; Laurent G Glance; Michael P Eaton; Bob Parshall; Scott McIntosh
Journal:  Anesth Analg       Date:  2007-03       Impact factor: 5.108

5.  A survey of the use of ultrasound guidance in internal jugular venous cannulation.

Authors:  T McGrattan; J Duffty; J S Green; N O'Donnell
Journal:  Anaesthesia       Date:  2008-11       Impact factor: 6.955

Review 6.  Percutaneous catheterization of the internal jugular vein.

Authors:  R J Defalque
Journal:  Anesth Analg       Date:  1974 Jan-Feb       Impact factor: 5.108

7.  Central vein catheterization. Failure and complication rates by three percutaneous approaches.

Authors:  J I Sznajder; F R Zveibil; H Bitterman; P Weiner; S Bursztein
Journal:  Arch Intern Med       Date:  1986-02

8.  A randomized study of left versus right internal jugular vein cannulation in adults.

Authors:  C A Sulek; M L Blas; E B Lobato
Journal:  J Clin Anesth       Date:  2000-03       Impact factor: 9.452

9.  Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients.

Authors:  Dimitrios Karakitsos; Nicolaos Labropoulos; Eric De Groot; Alexandros P Patrianakos; Gregorios Kouraklis; John Poularas; George Samonis; Dimosthenis A Tsoutsos; Manousos M Konstadoulakis; Andreas Karabinis
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

  9 in total
  1 in total

1.  Comment on: Unusual mechanical complications of central venous catheterization.

Authors:  Yong Han Kim
Journal:  Saudi Med J       Date:  2019-05       Impact factor: 1.484