| Literature DB >> 27350852 |
Praveen Perumal1, Gopi Naveen Chander1, Kuttae Viswanathan Anitha1, Jetti Ramesh Reddy1, Balasubramanium Muthukumar1.
Abstract
PURPOSE: This pilot study was to find the influence of complete denture on the brain activity and cognitive function of edentulous patients measured through Electroencephalogram (EEG) signals.Entities:
Keywords: Brain activity; Complete denture; Electroencephalography; Fast Fourier Transform; Geriatric; Power Spectral Density
Year: 2016 PMID: 27350852 PMCID: PMC4919488 DOI: 10.4047/jap.2016.8.3.187
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Fig. 1Study procedure flow chart.
Fig. 2Flow chart for EEG measurement.
Fig. 3Data acquisition of EEG.
Fig. 4Flow Chart for EEG Analysis.
Fig. 5Power spectral density value.
Power spectral density (relative units)
| S. NO: | EEG P1 | EEG P2 | EEG P3 | EEG P4 |
|---|---|---|---|---|
| 1 | 0.0025 | 0.0034 | 0.0038 | 0.0053 |
| 2 | 0.0039 | 0.0042 | 0.0051 | 0.0074 |
| 3 | 0.0095 | 0.0107 | 0.0131 | 0.0188 |
| 4 | 0.0039 | 0.0042 | 0.0057 | 0.0061 |
| 5 | 0.0133 | 0.0141 | 0.0133 | 0.0154 |
| 6 | 0.0062 | 0.0078 | 0.0099 | 0.0121 |
| 7 | 0.0021 | 0.0023 | 0.0039 | 0.0042 |
| 8 | 0.0058 | 0.0119 | 0.0085 | 0.0123 |
| 9 | 0.0012 | 0.0067 | 0.0042 | 0.0080 |
| 10 | 0.0016 | 0.0025 | 0.0026 | 0.0054 |
| 11 | 0.0121 | 0.0131 | 0.0167 | 0.0170 |
| 12 | 0.0049 | 0.0049 | 0.0032 | 0.0046 |
| 13 | 0.0026 | 0.0013 | 0.0018 | 0.0032 |
| 14 | 0.0133 | 0.0143 | 0.0133 | 0.0178 |
| 15 | 0.0039 | 0.0045 | 0.0042 | 0.0055 |
| 16 | 0.0082 | 0.0093 | 0.0095 | 0.0096 |
| 17 | 0.0056 | 0.0058 | 0.0067 | 0.0069 |
| 18 | 0.0124 | 0.0135 | 0.0114 | 0.0144 |
| 19 | 0.0067 | 0.0074 | 0.0087 | 0.0089 |
| 20 | 0.0075 | 0.0076 | 0.0078 | 0.0083 |
EEG p1: Edentulous phase before chewing, EEG p2: Edentulous phase after chewing, EEG p3: Post denture insertion adaptive phase before chewing, EEG p4: Post denture insertion adaptive phase after chewing.
Paired samples t-test to compare the mean value
| Pair | Variables | N | Mean | SD | t value | |
|---|---|---|---|---|---|---|
| Pair 1 | EEG p1 | 20 | 0.00641 | 0.0039 | 3.566 | .002 |
| EEG p3 | 20 | 0.0077 | 0.0042 | |||
| Pair 2 | EEG p2 | 20 | 0.0073 | 0.0039 | 4.974 | < .001 |
| EEG p4 | 20 | 0.0096 | 0.0048 | |||
| Pair 3 | EEG p1 | 20 | 0.0064 | 0.0039 | 3.671 | .002 |
| EEG p2 | 20 | 0.0073 | 0.0039 | |||
| Pair 4 | EEG p3 | 20 | 0.0077 | 0.0042 | 5.202 | < .001 |
| EEG p4 | 20 | 0.0096 | 0.0048 |
EEG p1: Edentulous phase before chewing, EEG p2: Edentulous phase after chewing, EEG p3: Post denture insertion adaptive phase before chewing, EEG p4: Post denture insertion adaptive phase after chewing.
Fig. 6Mean values of edentulous phase and post denture insertion adaptive phase before and after chewing.