Abstract

Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects caused by the limited spatial resolution of the positron emission tomography scanners. In this work, a practical image derived input function extraction method is presented, which only requires segmentation of the carotid arteries from MR images. The simulation study results showed that at least 92% of the true intensity could be recovered after the partial volume correction. Results from 19 subjects showed that the mean cerebral metabolic rate of glucose calculated using arterial samples and partial volume corrected image derived input function were 26.9 and 25.4 mg/min/100 g, respectively, for the grey matter and 7.2 and 6.7 mg/min/100 g for the white matter. No significant difference in the estimated cerebral metabolic rate of glucose values was observed between arterial samples and corrected image derived input function (p > 0.12 for grey matter and white matter). Hence, the presented image derived input function extraction method can be a practical alternative to noninvasively analyze dynamic 18F-fluorodeoxyglucose data without the need for blood sampling.

Entities:  

Keywords:  MRI; Positron emission tomography; brain imaging; carotid artery; kinetic modelling

Mesh:

Substances:

Year:  2016        PMID: 27342321      PMCID: PMC5453460          DOI: 10.1177/0271678X16656197

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  20 in total

1.  A global optimisation method for robust affine registration of brain images.

Authors:  M Jenkinson; S Smith
Journal:  Med Image Anal       Date:  2001-06       Impact factor: 8.545

2.  Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

Authors:  H W Müller-Gärtner; J M Links; J L Prince; R N Bryan; E McVeigh; J P Leal; C Davatzikos; J J Frost
Journal:  J Cereb Blood Flow Metab       Date:  1992-07       Impact factor: 6.200

3.  Comparison of image-derived and arterial input functions for estimating the rate of glucose metabolism in therapy-monitoring 18F-FDG PET studies.

Authors:  Lioe-Fee de Geus-Oei; Eric P Visser; Paul F M Krabbe; Bas A van Hoorn; Emile B Koenders; Antoon T Willemsen; Jan Pruim; Frans H M Corstens; Wim J G Oyen
Journal:  J Nucl Med       Date:  2006-06       Impact factor: 10.057

4.  User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability.

Authors:  Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig
Journal:  Neuroimage       Date:  2006-03-20       Impact factor: 6.556

Review 5.  Image-derived input function for brain PET studies: many challenges and few opportunities.

Authors:  Paolo Zanotti-Fregonara; Kewei Chen; Jeih-San Liow; Masahiro Fujita; Robert B Innis
Journal:  J Cereb Blood Flow Metab       Date:  2011-08-03       Impact factor: 6.200

6.  Correction for partial volume effects in PET: principle and validation.

Authors:  O G Rousset; Y Ma; A C Evans
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

7.  Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET.

Authors:  E Meyer
Journal:  J Nucl Med       Date:  1989-06       Impact factor: 10.057

8.  Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow.

Authors:  Yi Su; Ana M Arbelaez; Tammie L S Benzinger; Abraham Z Snyder; Andrei G Vlassenko; Mark A Mintun; Marcus E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  2012-10-17       Impact factor: 6.200

9.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data.

Authors:  C S Patlak; R G Blasberg; J D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  1983-03       Impact factor: 6.200

10.  Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography.

Authors:  D Feng; S C Huang; X Wang
Journal:  Int J Biomed Comput       Date:  1993-03
View more
  15 in total

1.  Image-derived input function estimation on a TOF-enabled PET/MR for cerebral blood flow mapping.

Authors:  Mohammad Mehdi Khalighi; Timothy W Deller; Audrey Peiwen Fan; Praveen K Gulaka; Bin Shen; Prachi Singh; Jun-Hyung Park; Frederick T Chin; Greg Zaharchuk
Journal:  J Cereb Blood Flow Metab       Date:  2017-02-03       Impact factor: 6.200

2.  Human non-REM sleep and the mean global BOLD signal.

Authors:  Mark P McAvoy; Enzo Tagliazucchi; Helmut Laufs; Marcus E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  2018-08-03       Impact factor: 6.200

3.  PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-compatible PET System.

Authors:  Shouyi Wei; Nandita Joshi; Michael Salerno; David Ouellette; Lemise Saleh; Christine DeLorenzo; Craig Woody; David Schlyer; Martin L Purschke; Jean-Francois Pratte; Sachin Junnarkar; Michael Budassi; Tuoyu Cao; Jack Fried; Joel S Karp; Paul Vaska
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-09-13

4.  First results on kinetic modelling and parametric imaging of dynamic 18F-FDG datasets from a long axial FOV PET scanner in oncological patients.

Authors:  Hasan Sari; Clemens Mingels; Ian Alberts; Jicun Hu; Dorothee Buesser; Vijay Shah; Robin Schepers; Patrik Caluori; Vladimir Panin; Maurizio Conti; Ali Afshar-Oromieh; Kuangyu Shi; Lars Eriksson; Axel Rominger; Paul Cumming
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-01-04       Impact factor: 10.057

5.  Non-invasive kinetic modelling of PET tracers with radiometabolites using a constrained simultaneous estimation method: evaluation with 11C-SB201745.

Authors:  Hasan Sari; Kjell Erlandsson; Lisbeth Marner; Ian Law; Henrik B W Larsson; Kris Thielemans; Sébastien Ourselin; Simon Arridge; David Atkinson; Brian F Hutton
Journal:  EJNMMI Res       Date:  2018-07-03       Impact factor: 3.138

6.  Simulation study of a coincidence detection system for non-invasive determination of arterial blood time-activity curve measurements.

Authors:  Yassine Toufique; Othmane Bouhali; Pauline Negre; Jim O' Doherty
Journal:  EJNMMI Phys       Date:  2020-05-07

7.  Partial-volume correction in dynamic PET-CT: effect on tumor kinetic parameter estimation and validation of simplified metrics.

Authors:  M C F Cysouw; S V S Golla; V Frings; E F Smit; O S Hoekstra; G M Kramer; R Boellaard
Journal:  EJNMMI Res       Date:  2019-02-04       Impact factor: 3.138

8.  Towards quantitative [18F]FDG-PET/MRI of the brain: Automated MR-driven calculation of an image-derived input function for the non-invasive determination of cerebral glucose metabolic rates.

Authors:  Lalith Ks Sundar; Otto Muzik; Lucas Rischka; Andreas Hahn; Ivo Rausch; Rupert Lanzenberger; Marius Hienert; Eva-Maria Klebermass; Frank-Günther Füchsel; Marcus Hacker; Magdalena Pilz; Ekaterina Pataraia; Tatjana Traub-Weidinger; Thomas Beyer
Journal:  J Cereb Blood Flow Metab       Date:  2018-05-23       Impact factor: 6.200

Review 9.  Methods for Quantifying Neurotransmitter Dynamics in the Living Brain With PET Imaging.

Authors:  Jenny Ceccarini; Heather Liu; Koen Van Laere; Evan D Morris; Christin Y Sander
Journal:  Front Physiol       Date:  2020-07-21       Impact factor: 4.566

10.  Image-Derived Input Functions for Quantification of A1 Adenosine Receptors Availability in Mice Brains Using PET and [18F]CPFPX.

Authors:  Xuan He; Franziska Wedekind; Tina Kroll; Angela Oskamp; Simone Beer; Alexander Drzezga; Johannes Ermert; Bernd Neumaier; Andreas Bauer; David Elmenhorst
Journal:  Front Physiol       Date:  2020-01-29       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.