Literature DB >> 27339301

Effects of voxel size and resolution on the accuracy of endodontic length measurement using cone beam computed tomography.

Ali Murat Aktan1, Cihan Yildirim2, Emrah Karataşlıoğlu2, Mehmet Ertuğrul Çiftçi3, Fatih Aksoy2.   

Abstract

An accurate determination of the working length is indispensable for successful endodontic treatment. The aim of this study was to determine the influence of the voxel size and resolution of CBCT on measuring root canal working length. Thirty extracted single-rooted permanent teeth were used for this study. The working lengths of the teeth were determined by a researcher inserted a K-file into each canal until the tip became visible through the major foramen. The file was withdrawn until its tip was seen at the level of the coronal-most border of the major foramen under. The rubber stop was adjusted to the occlusal reference and the distance from the stop to the false tip was measured with digital calipers and recorded as the actual working length. The CBCT images were obtained with a Planmeca ProMax 3D Mid (Planmeca, Helsinki, Finland) using four sets of settings: from voxel size 0.5mm to voxel size 1.0mm. These measurements were compared with actual lengths (as a control group) using Analysis of Variance and the Dunnett Post Hoc Test. The Pearson correlation coefficient (r) and 95% confidence intervals were calculated to compare all measurement methods. The significance level was set at P<0.05. No significant difference was found among CBCT groups and working length. A highest correlation was found between the actual length and smallest voxel size and highest CBCT measurements (r=0.94). CBCT imaging can be used endodontic working length measurement and the smallest voxel size and highest resolution yielded more accurate results.
Copyright © 2016 Elsevier GmbH. All rights reserved.

Keywords:  CBCT; Resolution; Voxel; Working length

Mesh:

Year:  2016        PMID: 27339301     DOI: 10.1016/j.aanat.2016.05.005

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  4 in total

Review 1.  Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis.

Authors:  Andrew Paterson; Vittorio Franco; Shanon Patel; Federico Foschi
Journal:  Imaging Sci Dent       Date:  2020-09-16

2.  Root canal curvature as a prognostic factor influencing the diagnostic accuracy of radiographic working length determination and postoperative canal axis modification: an in vitro comparative study.

Authors:  Bestoon Mohammed Faraj
Journal:  BMC Oral Health       Date:  2021-03-02       Impact factor: 2.757

3.  In vitro Evaluation of the Accuracy of the Root Zx in the Presence of Naocl 2.5% and Chlorhexidine 0.2.

Authors:  Marjan Bolbolian; Siamak Golchin; Seyedmatin Faegh
Journal:  J Clin Exp Dent       Date:  2018-11-01

4.  Preoperative Estimation of Endodontic Working Length with Cone-Beam Computed Tomography and Standardized Paralleling Technique in comparison to Its Real Length.

Authors:  Bestoon Mohammed Faraj
Journal:  Biomed Res Int       Date:  2020-10-10       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.