Quantitative susceptibility mapping (QSM) estimates the underlying tissue magnetic susceptibility from the gradient echo (GRE) phase signal through background phase removal and dipole inversion steps. Each of these steps typically requires the solution of an ill-posed inverse problem and thus necessitates additional regularization. Recently developed single-step QSM algorithms directly relate the unprocessed GRE phase to the unknown susceptibility distribution, thereby requiring the solution of a single inverse problem. In this work, we show that such a holistic approach provides susceptibility estimation with artifact mitigation and develop efficient algorithms that involve simple analytical solutions for all of the optimization steps. Our methods employ total variation (TV) and total generalized variation (TGV) to jointly perform the background removal and dipole inversion in a single step. Using multiple spherical mean value (SMV) kernels of varying radii permits high-fidelity background removal whilst retaining the phase information in the cortex. Using numerical simulations, we demonstrate that the proposed single-step methods reduce the reconstruction error by up to 66% relative to the multi-step methods that involve SMV background filtering with the same number of SMV kernels, followed by TV- or TGV-regularized dipole inversion. In vivo single-step experiments demonstrate a dramatic reduction in dipole streaking artifacts and improved homogeneity of image contrast. These acquisitions employ the rapid three-dimensional echo planar imaging (3D EPI) and Wave-CAIPI (controlled aliasing in parallel imaging) trajectories for signal-to-noise ratio-efficient whole-brain imaging. Herein, we also demonstrate the multi-echo capability of the Wave-CAIPI sequence for the first time, and introduce an automated, phase-sensitive coil sensitivity estimation scheme based on a 4-s calibration acquisition.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Wave-CAIPI; alternating direction method of multipliers (ADMM); quantitative susceptibility mapping (QSM); total generalized variation (TGV); total variation (TV)

Mesh:

Year:  2016        PMID: 27332141      PMCID: PMC5179325          DOI: 10.1002/nbm.3570

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  45 in total

1.  Fast phase unwrapping algorithm for interferometric applications.

Authors:  Marvin A Schofield; Yimei Zhu
Journal:  Opt Lett       Date:  2003-07-15       Impact factor: 3.776

2.  Parallel MR image reconstruction using augmented Lagrangian methods.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2010-11-18       Impact factor: 10.048

3.  High-field MRI of brain cortical substructure based on signal phase.

Authors:  Jeff H Duyn; Peter van Gelderen; Tie-Qiang Li; Jacco A de Zwart; Alan P Koretsky; Masaki Fukunaga
Journal:  Proc Natl Acad Sci U S A       Date:  2007-06-22       Impact factor: 11.205

4.  Whole brain susceptibility mapping using compressed sensing.

Authors:  Bing Wu; Wei Li; Arnaud Guidon; Chunlei Liu
Journal:  Magn Reson Med       Date:  2011-06-10       Impact factor: 4.668

5.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

6.  Morphology enabled dipole inversion (MEDI) from a single-angle acquisition: comparison with COSMOS in human brain imaging.

Authors:  Tian Liu; Jing Liu; Ludovic de Rochefort; Pascal Spincemaille; Ildar Khalidov; James Robert Ledoux; Yi Wang
Journal:  Magn Reson Med       Date:  2011-04-04       Impact factor: 4.668

7.  Combining phase images from multi-channel RF coils using 3D phase offset maps derived from a dual-echo scan.

Authors:  Simon Robinson; Günther Grabner; Stephan Witoszynskyj; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2011-01-19       Impact factor: 4.668

8.  Fast quantitative susceptibility mapping using 3D EPI and total generalized variation.

Authors:  Christian Langkammer; Kristian Bredies; Benedikt A Poser; Markus Barth; Gernot Reishofer; Audrey Peiwen Fan; Berkin Bilgic; Franz Fazekas; Caterina Mainero; Stefan Ropele
Journal:  Neuroimage       Date:  2015-02-27       Impact factor: 6.556

9.  Fast image reconstruction with L2-regularization.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Audrey P Fan; Kawin Setsompop; Stephen F Cauley; Lawrence L Wald; Elfar Adalsteinsson
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

10.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more
  12 in total

1.  Nonlinear dipole inversion (NDI) enables robust quantitative susceptibility mapping (QSM).

Authors:  Daniel Polak; Itthi Chatnuntawech; Jaeyeon Yoon; Siddharth Srinivasan Iyer; Carlos Milovic; Jongho Lee; Peter Bachert; Elfar Adalsteinsson; Kawin Setsompop; Berkin Bilgic
Journal:  NMR Biomed       Date:  2020-02-20       Impact factor: 4.044

2.  Simultaneous Time Interleaved MultiSlice (STIMS) for Rapid Susceptibility Weighted acquisition.

Authors:  Berkin Bilgic; Huihui Ye; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2017-04-20       Impact factor: 6.556

3.  Susceptibility mapping of the dural sinuses and other superficial veins in the brain.

Authors:  Sagar Buch; Yongsheng Chen; E Mark Haacke
Journal:  Magn Reson Imaging       Date:  2018-10-21       Impact factor: 2.546

4.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

5.  Quantitative susceptibility mapping: Report from the 2016 reconstruction challenge.

Authors:  Christian Langkammer; Ferdinand Schweser; Karin Shmueli; Christian Kames; Xu Li; Li Guo; Carlos Milovic; Jinsuh Kim; Hongjiang Wei; Kristian Bredies; Sagar Buch; Yihao Guo; Zhe Liu; Jakob Meineke; Alexander Rauscher; José P Marques; Berkin Bilgic
Journal:  Magn Reson Med       Date:  2017-07-31       Impact factor: 4.668

6.  The 2016 QSM Challenge: Lessons learned and considerations for a future challenge design.

Authors:  Carlos Milovic; Cristian Tejos; Julio Acosta-Cabronero; Pinar Senay Özbay; Ferdinand Schwesser; Jose Pedro Marques; Pablo Irarrazaval; Berkin Bilgic; Christian Langkammer
Journal:  Magn Reson Med       Date:  2020-02-21       Impact factor: 4.668

7.  Single-step calculation of susceptibility through multiple orientation sampling.

Authors:  Lin Chen; Shuhui Cai; Peter C M van Zijl; Xu Li
Journal:  NMR Biomed       Date:  2021-04-06       Impact factor: 4.478

8.  On the sensitivity of quantitative susceptibility mapping for measuring trabecular bone density.

Authors:  Maximilian N Diefenbach; Jakob Meineke; Stefan Ruschke; Thomas Baum; Alexandra Gersing; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2018-09-28       Impact factor: 4.668

Review 9.  Non-Invasive Evaluation of Cerebral Microvasculature Using Pre-Clinical MRI: Principles, Advantages and Limitations.

Authors:  Bram Callewaert; Elizabeth A V Jones; Uwe Himmelreich; Willy Gsell
Journal:  Diagnostics (Basel)       Date:  2021-05-21

10.  A robust multi-scale approach to quantitative susceptibility mapping.

Authors:  Julio Acosta-Cabronero; Carlos Milovic; Hendrik Mattern; Cristian Tejos; Oliver Speck; Martina F Callaghan
Journal:  Neuroimage       Date:  2018-07-31       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.